and used to estimate the temperature of the Sun's surface. An actinometer is an instrument that can measure the heating power of radiation. Actinometers are used in meteorology to measure solar radiation as pyranometers, pyrheliometers and net radiometers. An actinometer is a chemical system or physical device which determines the number of photons in a beam integrally or per unit time. This name is commonly applied to devices used in the ultraviolet and visible wavelength ranges. For example, solutions of iron(III) oxalate can be used as a chemical actinometer, while bolometers, thermopiles, and photodiodes are physical devices giving a reading that can be correlated to the number of photons detected.
and used to estimate the temperature of the Sun's surface.]] An actinometer is an instrument that can measure the heating power of radiation. Actinometers are used in meteorology to measure solar radiation as pyranometers, pyrheliometers and net radiometers. An actinometer is a chemical system or physical device which determines the number of photons in a beam integrally or per unit time. This name is commonly applied to devices used in the ultraviolet and visible wavelength ranges. For example, solutions of iron(III) oxalate can be used as a chemical actinometer, while bolometers, thermopiles, and photodiodes are physical devices giving a reading that can be correlated to the number of photons detected.
History
Swiss physicist Horace-Bénédict de Saussure invented an early version in the late 18th century. His design used a blackened thermometer enclosed in a glass sphere to measure solar radiation, which he referred to as a "heliothermometer." This instrument is considered one of the first tools to systematically measure solar intensity. John Herschel further developed actinometers in the 19th century, including a design involving photochemical reactions to measure sunlight intensity, which was a significant step forward. Herschel's actinometer involved observing the rate of a chemical reaction under sunlight, which allowed for more precise quantification of solar energy. Herschel's version was influential and helped standardize measurements of solar energy. Herschel introduced the term actinometer, the first of many uses of the prefix actin for scientific instruments, effects, and processes. The actinograph is a related device for estimating the actinic power of lighting for photography.
Chemical actinometry in the visible range
Meso-diphenylhelianthrene can be used for chemical actinometry in the visible range (400–700 nm). This chemical measures in the 475–610 nm range, but measurements in wider spectral ranges can be done with this chemical if the emission spectrum of the light source is known. \Phi_{x} = \Phi_{ref} \cdot \frac{\Delta A_{x}(\lambda_{1})}{\Delta \varepsilon_{x}(\lambda_{1})} \cdot \frac{\Delta \varepsilon_{ref}(\lambda_{2})}{\Delta A_{ref}(\lambda_{2})} \cdot \frac{1 - 10^{-A_{ref}(\lambda_{ex})}}{ 1 - 10^{-A_{x}(\lambda_{ex})}} Note that in general \Delta \varepsilon means the difference in molar absorption coefficients contributing before and after the excitation so that \Delta \varepsilon = \varepsilon_{after} - \varepsilon_{before} . \Delta A_{x}(\lambda_{1}) and \Delta A_{ref}(\lambda_{2}) are difference absorbance observed for compound of interest and the reference compound, respectively, for the relevant wavelengths. The formation quantum yield \Phi_{ref} , as well as the difference molar absorption coefficient \Delta \varepsilon_{ref}(\lambda_{2}) associated with the reference compound should be known before the experiment. The last term in the equation serves as a correction if the stationary absorbances of prepared solutions are not perfectly the same, however it shouldn't be far from unity. Excitation energy should be low enough to avoid nonlinear effect such as multiphoton absorption. This technique allows for characterization of certain photoproducts without explicit calculation of the number of absorbed photons, benefiting from the fact that imperfections of the measurement contribute in the same way for the compound of interest and the reference compound, so they effectively compensate.