ADF-GLS test

In statistics and econometrics, the ADF-GLS test (or DF-GLS test) is a test for a unit root in an economic time series sample.

Uses your system voice; voice and rate in settings.

Snapshot

≈ 3 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

In statistics and econometrics, the ADF-GLS test (or DF-GLS test) is a test for a unit root in an economic time series sample. It was developed by Elliott, Rothenberg and Stock (ERS) in 1992 as a modification of the augmented Dickey–Fuller test (ADF). A unit root test determines whether a time series variable is non-stationary using an autoregressive model.

For series featuring deterministic components in the form of a constant or a linear trend then ERS developed an asymptotically point optimal test to detect a unit root. This testing procedure dominates other existing unit root tests in terms of power.

It locally de-trends (de-means) data series to efficiently estimate the deterministic parameters of the series, and use the transformed data to perform a usual ADF unit root test. This procedure helps to remove the means and linear trends for series that are not far from the non-stationary region.

Consider a simple time series model y_{t}=d_t+u_{t}\, with u_{t}=\rho u_{t-1}+e_{t}\, where d_t\, is the deterministic part and u_{t}\, is the stochastic part of y_{t}\, . When the true value of \rho \, is close to 1, estimation of the model, i.e. d_t\, will pose efficiency problems because the y_{t}\, will be close to nonstationary.

In this setting, testing for the stationarity features of the given times series will also be subject to general statistical problems. To overcome such problems ERS suggested to locally difference the time series. Consider the case where closeness to 1 for the autoregressive parameter is modelled as \rho=1-\frac{c}{T} \, where T \, is the number of observations.

Now consider filtering the series using 1-\frac{\bar{c}}{T}L \, with L \, being a standard lag operator, i.e. \bar{y}_t=y_t-(\bar{c}/T)y_{t-1} \, . Working with \bar{y}_t \, would result in power gain, as ERS show, when testing the stationarity features of y_t \, using the augmented Dickey-Fuller test.

This is a point optimal test for which \bar{c} \, is set in such a way that the test would have a 50 percent power when the alternative is characterized by \rho=1-c/T \, for c=\bar{c} \, . Depending on the specification of d_t \, , \bar{c} \, will take different values.

Text derived from https://en.wikipedia.org/w/index.php?oldid=1311790891 under CC BY-SA 4.0; modifications have been made.

Provenance

snapshot enwiki-001311790891 · captured 2025-09-16 · not yet sealed in the ledger · verify the chain · version history

Cite this page as: encyclopegia.org, “ADF-GLS test”, snapshot enwiki-001311790891. https://encyclopegia.org/a/adf-gls-test

Sources cited in this revision

1 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.