The affinity laws (also known as the "Fan Laws" or "Pump Laws") for pumps/fans are used in hydraulics, hydronics and/or HVAC to express the relationship between variables involved in pump or fan performance (such as head, volumetric flow rate, shaft speed) and power. They apply to pumps, fans, and hydraulic turbines. In these rotary implements, the affinity laws apply both to centrifugal and axial flows. The laws are derived using the Buckingham π theorem. The affinity laws are useful as they allow the prediction of the head discharge characteristic of a pump or fan from a known characteristic measured at a different speed or impeller diameter. The only requirement is that the two pumps or fans are dynamically similar, that is, the ratios of the fluid forced are the same. It is also required that the two impellers' speed or diameter are running at the same efficiency. Understanding the affinity laws requires understanding the pump discharge and head coefficient dimensionless numbers. For a given pump, one can compute the discharge and head coefficients as follows: : { C_d } = { Q\over nD^3} : { C_h } = { gH\over n^2D^2} The coefficient for a given pump is considered to be constant over a range of input values. Therefore, you can estimate the impact of changing one variable while keeping the others constant.…
Article summary
The affinity laws (also known as the "Fan Laws" or "Pump Laws") for pumps/fans are used in hydraulics, hydronics and/or HVAC to express the relationship between variables involved in pump or fan performance (such as head, volumetric flow rate, shaft speed) and power. They apply to pumps, fans, and hydraulic turbines. In these rotary implements, the affinity laws apply both to centrifugal and axial flows. The laws are derived using the Buckingham π theorem. The affinity laws are useful as they allow the prediction of the head discharge characteristic of a pump or fan from a known characteristic measured at a different speed or impeller diameter. The only requirement is that the two pumps or fans are dynamically similar, that is, the ratios of the fluid forced are the same. It is also required that the two impellers' speed or diameter are running at the same efficiency. Understanding the affinity laws requires understanding the pump discharge and head coefficient dimensionless numbers. For a given pump, one can compute the discharge and head coefficients as follows: : { C_d } = { Q\over nD^3} : { C_h } = { gH\over n^2D^2} The coefficient for a given pump is considered to be constant over a range of input values. Therefore, you can estimate the impact of changing one variable while keeping the others constant.…
Key claims
No claims recorded.
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?
Bibliography
No sources recorded.