Alternating current
Alternating current (AC) is an electric current that periodically reverses direction and changes its magnitude continuously with time, in contrast to direct current (DC), which flows only in one direction.
≈ 15 min read
Alternating current. encyclopegia.org, snapshot enwiki-001378292341. /a/alternating-current
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
Alternating current (AC) is an electric current that periodically reverses direction and changes its magnitude continuously with time, in contrast to direct current (DC), which flows only in one direction. Alternating current is the form in which electric power is delivered to businesses and residences, and it is the form of electrical energy that consumers typically use when they plug kitchen appliances, televisions, fans and electric lamps into a wall socket.
The abbreviations AC and DC are often used to mean simply alternating and direct, respectively, as when they modify current or voltage. The usual waveform of alternating current in most electric power circuits is a sine wave, whose positive half-period corresponds with positive direction of the current and vice versa (the full period is called a cycle).
"Alternating current" most commonly refers to power distribution, but a wide range of other applications are technically alternating current although it is less common to describe them by that term. In many applications, like guitar amplifiers, different waveforms are used, such as triangular waves or square waves.
Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information such as sound (audio) or images (video) sometimes carried by modulation of an AC carrier signal. These currents typically alternate at higher frequencies than those used in power transmission.
P_{\rm w} = I^2 R \, . This means that when transmitting a fixed power on a given wire, if the current is halved (by doubling the voltage), the power loss due to the wire's resistance will be reduced by a factor of four. The power transmitted is equal to the product of the current and the voltage (assuming no phase difference); that is, P_{\rm t} = IV \, .
Consequently, power transmitted at a higher voltage requires less loss-producing current than for the same power at a lower voltage. Power is often transmitted at hundreds of kilovolts on pylons, and transformed down to tens of kilovolts to be transmitted on lower level lines, and finally transformed down to 100 V – 240 V for domestic use. lines use alternating currents to distribute power over long distances between electric generation plants and consumers.
The lines in the picture are located in eastern Utah. High voltages have disadvantages, such as the increased insulation required, and generally increased difficulty in their safe handling. In a power plant, energy is generated at a convenient voltage for the design of a generator, and then stepped up to a high voltage for transmission.
Near the loads, the transmission voltage is stepped down to the voltages used by equipment. Consumer voltages vary somewhat depending on the country and size of load, but generally motors and lighting are built to use up to a few hundred volts between phases.
The voltage delivered to equipment such as lighting and motor loads is standardized, with an allowable range of voltage over which equipment is expected to operate. Standard power utilization voltages and percentage tolerance vary in the different mains power systems found in the world.
High-voltage direct-current (HVDC) electric power transmission systems have become more viable as technology has provided efficient means of changing the voltage of DC power. Transmission with high voltage direct current was not feasible in the early days of electric power transmission, as there was then no economically viable way to step the voltage of DC down for end user applications such as lighting incandescent bulbs.
Three-phase electrical generation is very common. The simplest way is to use three separate coils in the generator stator, physically offset by an angle of 120° (one-third of a complete 360° phase) to each other. Three current waveforms are produced that are equal in magnitude and 120° out of phase to each other.
If coils are added opposite to these (60° spacing), they generate the same phases with reverse polarity and can be wired together. In practice, higher pole orders are commonly used. For example, a 12-pole machine would have 36 coils (10° spacing).
The advantage is that lower rotational speeds can be used to generate the same frequency. For example, a 2-pole machine running at 3600 rpm and a 12-pole machine running at 600 rpm produce the same frequency; the lower speed is preferable for larger machines. If the load on a three-phase system is balanced equally among the phases, no current flows through the neutral point.
Even in the worst-case unbalanced (linear) load, the neutral current will not exceed the highest of the phase currents. Non-linear loads (e.g. the switch-mode power supplies widely used) may require an oversized neutral bus and neutral conductor in the upstream distribution panel to handle harmonics.
Harmonics can cause neutral conductor current levels to exceed that of one or all phase conductors. For three-phase at utilization voltages a four-wire system is often used. When stepping down three-phase, a transformer with a Delta (3-wire) primary and a Star (4-wire, center-earthed) secondary is often used so there is no need for a neutral on the supply side.
For smaller customers (just how small varies by country and age of the installation) only a single phase and neutral, or two phases and neutral, are taken to the property. For larger installations, all three phases and neutral are taken to the main distribution panel. From the three-phase main panel, both single and three-phase circuits may lead off.
Three-wire single-phase systems, with a single center-tapped transformer giving two live conductors, is a common distribution scheme for residential and small commercial buildings in North America. This arrangement is sometimes incorrectly referred to as two phase.
A similar method is used for a different reason on construction sites in the UK. Small power tools and lighting are supposed to be supplied by a local center-tapped transformer with a voltage of 55 V between each power conductor and earth. This significantly reduces the risk of electric shock in the event that one of the live conductors becomes exposed through an equipment fault whilst still allowing a reasonable voltage of 110 V between the two conductors for running the tools.
An additional wire, called the bond (or earth) wire, is often connected between non-current-carrying metal enclosures and earth ground. This conductor provides protection from electric shock due to accidental contact of circuit conductors with the metal chassis of portable appliances and tools.
Bonding all non-current-carrying metal parts into one complete system ensures there is always a low electrical impedance path to ground sufficient to carry any fault current for as long as it takes for the system to clear the fault. This low impedance path allows the maximum amount of fault current, causing the overcurrent protection device (breakers, fuses) to trip or burn out as quickly as possible, bringing the electrical system to a safe state.
All bond wires are bonded to ground at the main service panel, as is the neutral/identified conductor if present.
Low frequency
A low frequency eases the design of electric motors, particularly for hoisting, crushing and rolling applications, and commutator-type traction motors for applications such as railways. However, low frequency also causes noticeable flicker in arc lamps and incandescent light bulbs.
The use of lower frequencies also provided the advantage of lower transmission losses, which are proportional to frequency. The original Niagara Falls generators were built to produce 25 Hz power, as a compromise between low frequency for traction and heavy induction motors, while still allowing incandescent lighting to operate (although with noticeable flicker).
Most of the 25 Hz residential and commercial customers for Niagara Falls power were converted to 60 Hz by the late 1950s, although some 25 Hz industrial customers still existed as of the start of the 21st century. 16.7 Hz power (formerly 16 2/3 Hz) is still used in some European rail systems, such as in Austria, Germany, Norway, Sweden and Switzerland.
High frequency
Off-shore, military, textile industry, marine, aircraft, and spacecraft applications sometimes use 400 Hz, for benefits of reduced weight of apparatus or higher motor speeds. Computer mainframe systems were often powered by 400 Hz or 415 Hz for benefits of ripple reduction while using smaller internal AC to DC conversion units.
Formulation
Alternating currents are accompanied (or caused) by alternating voltages. An AC voltage v can be described mathematically as a function of time by the following equation: v(t) = V_\text{peak}\sin(\omega t) , where V_\text{peak} is the peak voltage (unit: volt), \omega is the angular frequency (unit: radians per second).
The angular frequency is related to the physical frequency, f (unit: hertz), which represents the number of cycles per second, by the equation \omega = 2\pi f . t is the time (unit: second). The peak-to-peak value of an AC voltage is defined as the difference between its positive peak and its negative peak.
Since the maximum value of \sin(x) is +1 and the minimum value is −1, an AC voltage swings between +V_\text{peak} and -V_\text{peak} . The peak-to-peak voltage, usually written as V_\text{pp} or V_\text{P-P} , is therefore V_\text{peak} - (-V_\text{peak}) = 2 V_\text{peak} .
Root mean square voltage
(RMS) value at {\sqrt {0.5}} (about 0.707).|alt=A graph of sin(x) with a dashed line at y=sin(45) Below an AC waveform (with no DC component) is assumed. The RMS voltage is the square root of the mean over one cycle of the square of the instantaneous voltage. {{unordered list | For an arbitrary periodic waveform v(t) of period T : V_\text{rms} = \sqrt{\frac{1}{T} \int_0^{T}{[v(t)]^2 dt}}. | For a sinusoidal voltage: \begin{align} V_\text{rms} &= \sqrt{\frac{1}{T} \int_0^{T}[{V_\text{peak}\sin(\omega t + \phi)]^2 dt}}\\ &= V_\text{peak}\sqrt{\frac{1}{2T} \int_0^{T}[{1 - \cos(2\omega t + 2\phi)] dt}}\\ &= V_\text{peak}\sqrt{\frac{1}{2T} \int_0^{T}{dt}}\\ &= \frac{V_\text{peak}}{\sqrt {2}} \end{align} where the trigonometric identity \sin^2(x) = \frac {1 - \cos(2x)}{2} has been used and the factor \sqrt{2} is called the crest factor, which varies for different waveforms. | For a triangle waveform centered about zero V_\text{rms} = \frac{V_\text{peak}}{\sqrt{3}}. | For a square waveform centered about zero V_\text{rms} = V_\text{peak}. }} p(t) = \frac{v^2(t)}{R} , where R represents a load resistance.
Rather than using instantaneous power, p(t) , it is more practical to use a time-averaged power (where the averaging is performed over any integer number of cycles). Therefore, AC voltage is often expressed as a root mean square (RMS) value, written as V_\text{rms} , because P_\text{average} = \frac{{V_\text{rms}}^2}{R}.
Power oscillation: \begin{align} v(t) &= V_\text{peak}\sin(\omega t) \\ i(t) &= \frac{v(t)}{R} = \frac{V_\text{peak}}{R}\sin(\omega t) \\ p(t) &= v(t)i(t) = \frac{(V_\text{peak})^2}{R}\sin^2(\omega t) = \frac{(V_\text{peak})^2}{2 R} \ (1 - \cos(2 \omega t) ) \end{align} For this reason, AC power's waveform becomes Full-wave rectified sine, and its fundamental frequency is double that of the voltage's. V_\text{peak} = \sqrt{2}\ V_\text{rms} P_\text{peak} = \frac{(V_\text{rms})^2}{R}\frac{(V_\text{peak})^2}{(V_\text{rms})^2} = \text{P}_\text{average}\sqrt{2}^2 = \text{2}P_\text{average}. For 230 V AC, the peak voltage V_\text{peak} is therefore 230\text{ V}\times\sqrt{2} , which is about 325 V, and the peak power P_\text{peak} is 230 \times R \times W \times 2 , that is 460 RW.
During the course of one cycle (two cycle as the power) the voltage rises from zero to 325 V, the power from zero to 460 RW, and both falls through zero. Next, the voltage descends to reverse direction, −325 V, but the power ascends again to 460 RW, and both returns to zero.
Adoption
In May 1885, at the Hungarian National Exhibition in Budapest, Deri, Blathy, and Zipernowski held a large-scale demonstration of what is widely regarded as the prototype of modern AC lighting systems. Their system used 75 transformers in parallel connection, supplying 1,067 incandescent Edison lamps from an AC generator that provided 1,350 V. The AC power system was developed and adopted rapidly after 1886.
In March of that year, Westinghouse engineer William Stanley, designing a system based on the Gaulard and Gibbs transformer, demonstrated a lighting system in Great Barrington: A Siemens generator's voltage of 500 volts was converted into 3000 volts, and then the voltage was stepped down to 500 volts by six Westinghouse transformers. With this setup, the Westinghouse company successfully powered thirty 100-volt incandescent bulbs in twenty shops along the main street of Great Barrington.
By the fall of that year Ganz engineers installed a ZBD transformer power system with AC generators in Rome. [[File:WestinghouseEarlyACSystem1887-USP373035.png|thumb|Westinghouse Early AC System 1887 (US patent 373035) Based on Stanley's success, the new Westinghouse Electric went on to develop alternating current (AC) electric infrastructure throughout the United States.
The spread of Westinghouse and other AC systems triggered a push back in late 1887 by Thomas Edison (a proponent of direct current), who attempted to discredit alternating current as too dangerous in a public campaign called the "war of the currents". In 1888, alternating current systems gained further viability with the introduction of a functional AC motor, something these systems had lacked up till then.
The design, an induction motor, was independently invented by Galileo Ferraris and Nikola Tesla (with Tesla's design being licensed by Westinghouse in the US). This design was independently further developed into the modern practical three-phase form by Mikhail Dolivo-Dobrovolsky and Charles Eugene Lancelot Brown in Germany on one side, and Jonas Wenström in Sweden on the other, though Brown favored the two-phase system. The Ames Hydroelectric Generating Plant, constructed in 1890, was among the first hydroelectric alternating current power plants.
A long-distance transmission of single-phase electricity from a hydroelectric generating plant in Oregon at Willamette Falls sent power fourteen miles downriver to downtown Portland for street lighting in 1890. In 18911, another transmission system was installed in Telluride Colorado. The first three-phase system was established in 1891 in Frankfurt, Germany.
The Tivoli–Rome transmission was completed in 1892. The San Antonio Canyon Generator was the third commercial single-phase hydroelectric AC power plant in the United States to provide long-distance electricity. It was completed on December 31, 1892, by Almarian William Decker to provide power to the city of Pomona, California, which was 14 miles away.
Meanwhile, the possibility of transferring electrical power from a waterfall at a distance was explored at the Grängesberg mine in Sweden. A fall at Hällsjön, Smedjebackens kommun, where a small iron work had been located, was selected. In 1893, a three-phase system was used to transfer 400 horsepower a distance of , becoming the first commercial application.
In 1893, Westinghouse built an alternating current system for the Chicago World Exposition. In 1893, Decker designed the first American commercial three-phase power plant using alternating current—the hydroelectric Mill Creek No. 1 Hydroelectric Plant near Redlands, California.
Decker's design incorporated 10 kV three-phase transmission and established the standards for the complete system of generation, transmission and motors used in USA today. The original Niagara Falls Adams Power Plant with three two-phase generators was put into operation in August 1895, but was connected to the remote transmission system only in 1896.
The Jaruga Hydroelectric Power Plant in Croatia was set in operation two days later, on 28 August 1895. Its generator (42 Hz, 240 kW) was made and installed by the Hungarian company Ganz, while the transmission line from the power plant to the City of Šibenik was long, and the municipal distribution grid 3000 V/110 V included six transforming stations.
Alternating current circuit theory developed rapidly in the latter part of the 19th and early 20th century. Notable contributors to the theoretical basis of alternating current calculations include Charles Steinmetz, Oliver Heaviside, and many others.
Calculations in unbalanced three-phase systems were simplified by the symmetrical components methods discussed by Charles LeGeyt Fortescue in 1918.