Lesson plan
Amperometry
Amperometry in chemistry is the detection of ions in a solution based on electric current or changes in electric current. Amperometry is used in electrophysiology to study vesicle release events using a carbon fiber electrode. Unlike patch clamp techniques, the electrode used for amperometry is not inserted into or attached to the cell but brought nearby of the cell. The measurements from the electrode originate from an oxidizing reaction of a vesicle cargo released into the medium. Another technique used to measure vesicle release is capacitive measurements. It is the electric current measured between a pair of electrodes. The measured current is directly proportional to the concentration of the analyte. Example: Blood glucose monitor Carbon is used as a working electrode which is coated with mediator and glucose oxidase. Ag/AgCl is used as the reference electrode. The enzyme oxidase catalyzes the reaction of glucose with oxygen. Hydrogen peroxide concentration is measured by oxidation which occurs at +0.6V. H_2O_2 \longrightarrow O_2 + 2H^+ + 2e^- Current is directly proportional to H 2 O 2 concentration this in turn is directly proportional to glucose concentration. If O 2 is low, complete conversion is inhibited. Hence mediator ferrocene is introduced.…
Article summary
Amperometry in chemistry is the detection of ions in a solution based on electric current or changes in electric current. Amperometry is used in electrophysiology to study vesicle release events using a carbon fiber electrode. Unlike patch clamp techniques, the electrode used for amperometry is not inserted into or attached to the cell but brought nearby of the cell. The measurements from the electrode originate from an oxidizing reaction of a vesicle cargo released into the medium. Another technique used to measure vesicle release is capacitive measurements. It is the electric current measured between a pair of electrodes. The measured current is directly proportional to the concentration of the analyte. Example: Blood glucose monitor Carbon is used as a working electrode which is coated with mediator and glucose oxidase. Ag/AgCl is used as the reference electrode. The enzyme oxidase catalyzes the reaction of glucose with oxygen. Hydrogen peroxide concentration is measured by oxidation which occurs at +0.6V. H_2O_2 \longrightarrow O_2 + 2H^+ + 2e^- Current is directly proportional to H 2 O 2 concentration this in turn is directly proportional to glucose concentration. If O 2 is low, complete conversion is inhibited. Hence mediator ferrocene is introduced.…
Key claims
No claims recorded.
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?
Bibliography
No sources recorded.
Key claims and bibliography are generated from the same tracked claims and sources as the article page.