Aortic valve replacement

Aortic valve replacement is a cardiac surgery procedure whereby a failing aortic valve is replaced with an artificial heart valve.

Uses your system voice; voice and rate in settings.

Snapshot

≈ 7 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

Aortic valve replacement is a cardiac surgery procedure whereby a failing aortic valve is replaced with an artificial heart valve. The aortic valve may need to be replaced because of aortic regurgitation (back flow), or if the valve is narrowed by stenosis.

Current methods for aortic valve replacement include open-heart surgery, minimally invasive cardiac surgery (MICS), surgical aortic valve replacement (SAVR), percutaneous or transcatheter aortic valve replacement (TAVR; also PAVR, PAVI, TAVI), and robotic aortic valve replacement (RAVR). A cardiologist can evaluate whether a heart valve repair or valve replacement would be of benefit.

Types of valves

There are two basic types of replacement heart valve: tissue (bioprosthetic) valves and mechanical valves.

Tissue valves

Tissue heart valves are usually made from animal tissue (heterografts) mounted on a metal or polymer support. Bovine (cow) tissue is most commonly used, but some are made from porcine (pig) tissue. The tissue is treated to prevent rejection and calcification (where calcium builds up on the replacement valve and stops it working properly).

Occasionally, alternatives to animal tissue valves are used: aortic homografts and pulmonary autografts. An aortic homograft is an aortic valve from a human donor, retrieved either after their death or from their heart if they are undergoing a heart transplant.

A pulmonary autograft, also known as the Ross procedure, is where the aortic valve is removed and replaced with the patient's own pulmonary valve (the valve between the right ventricle and the pulmonary artery). A pulmonary homograft (a pulmonary valve taken from a cadaver) is then used to replace the patient's own pulmonary valve.

This procedure was first performed in 1967 and is used primarily in children, as it allows the patient's own pulmonary valve (now in the aortic position) to grow with the child. Tissue valves can last 10–20 years. However, they tend to deteriorate more quickly in younger patients.

New ways of preserving the tissue for longer are being investigated. One such preservation treatment is now being used in a commercially available tissue heart valve. In sheep and rabbit studies, the tissue (called RESILIA tissue) had less calcification than control tissue.

Mid-term data on the safety and haemodynamic performance of the Inspiris RESILIA aortic bioprosthesis are encouraging. Stented and stentless tissue valves are available. Stented valves come in sizes from 19 mm to 29 mm.

Stentless valves are directly sutured at the aortic root. The major advantage of stentless valves is that they limit patient–prosthesis mismatch (when the area of the prosthetic valve is too small in relation to the size of the patient, increasing the pressure inside the valve ) and can be helpful when dealing with small aortic root.

However, stentless valves take more time than stented valves to implant.

Mechanical valves

Mechanical valves are made from synthetic materials, such as titanium or pyrolytic carbon. Their durability is long life, while tissue valves can last for up to 15–20 years.

Since the risk of blood clots forming is higher with mechanical valves than with tissue valves, patients with mechanical heart valves are required to take anticoagulant (blood-thinning) drugs, such as warfarin, long-life, making them more prone to bleeding (1% per year). The sound of the valve can be heard very rarely, often as clicks, and might be disturbing.

The choice of prosthetic valve should be individualized, carefully considering each patient's unique circumstances. In that context, the new generation aortic mechanical valve (On-X) offers a potential lifetime solution without need for a repeat operation, while minimizing the risks of long-term anticoagulation due to reduced anticoagulation target INR of 1.5 to 2.0.

Valve selection

Valve choice is a balance between the lower durability of tissue valves and the increased risk of blood clots and bleeding with mechanical valves. Guidelines suggest that patient age, lifestyle and medical history should all be considered when choosing a valve.

Tissue valves deteriorate more rapidly in young patients and during pregnancy, but they are preferable for women who wish to have children because pregnancy increases the risk of blood clots. Typically, a mechanical valve is considered for patients under 60 years old, while a tissue valve is considered for patients over the age of 65 years.

Surgical replacement

from the aorta.]] Surgical aortic valve replacement is conventionally done through a median sternotomy, meaning the incision is made by cutting through the breastbone (sternum).

Once the protective membrane around the heart (pericardium) has been opened, the patient is cannulated (aortic cannulation by a cannula placed on the aorta and a venous canulation by a single atrial venous cannula inserted through the right atrium). The patient is put on a cardiopulmonary bypass machine, also known as the heart–lung machine.

This machine breathes for the patient and pumps their blood around their body while the surgeon replaces the heart valve. Once on cardiopulmonary bypass, the patient's heart is stopped (cardioplegia). This can be done with a Y-type cardioplegic infusion catheter placed on the aorta, de-aired and connected to the cardiopulmonary bypass machine.

Alternatively, a retrograde cardioplegic cannula can be inserted at the coronary sinus. Some surgeons also opt to place a vent in the left ventricle through the right superior pulmonary vein, because this helps to prevent left ventricular distention before and after cardiac arrest.

When the set-up is ready, the aorta is clamped shut with a cross-clamp to stop blood pumping through the heart and cardioplegia is infused. The surgeon incises the aorta a few milometers above the sinotubular junction (just above the coronary ostia, where the coronary arteries join the aorta) – a process known as aortotomy.

After this, cardioplegia is delivered directly through the ostia. The heart is now still and the surgeon removes the patient's diseased aortic valve. The cusps of the aortic valve are excised, and calcium is removed (debrided) from the aortic annulus.

The surgeon measures the size of the aortic annulus and fits a mechanical or tissue valve of the appropriate size. Usually the valve is fixed in place with sutures, although some sutureless valves are available. If the patient's aortic root is very small, the sutures are placed outside of the aortic root instead of at the annulus, to gain some extra space.

Once the valve is in place and the aorta has been closed, patient is placed in a Trendelenburg position and the heart is de-aired and restarted. The patient is taken off the cardiopulmonary bypass machine. Transesophageal echocardiogram (an ultrasound of the heart done through the esophagus) can be used to verify that the new valve is functioning properly.

Pacing wires are usually put in place, so that the heart can be manually controlled should any complications arise after surgery. Drainage tubes are also inserted, to drain fluids from the chest. These are usually removed within 36 hours, while the pacing wires are generally left in place until right before the patient is discharged from the hospital.

Patient–prosthesis mismatch

When dealing with a small aortic annulus, the surgeon might have to insert a prosthetic aortic valve of small size, with an orifice too small in relation to the size of the patient (patient–prosthesis mismatch). This increases the pressure of the blood flowing through the valve, and can lead to worse outcomes. Various techniques, including stentless valves, have been utilized to avoid this problem.