An autoclave is a machine used to carry out industrial and scientific processes requiring elevated temperature and pressure in relation to ambient pressure and temperature. Autoclaves are found in many medical settings, laboratories, and other places that need to ensure the sterility of an object. The autoclave was invented by Charles Chamberland in 1879, although a precursor known as the steam digester was created by Denis Papin in 1679. The name comes from Greek auto-, meaning "self", and Latin clavis meaning "key", thus a self-locking device.

All autoclaves operate according to the same fundamental principles as a kitchen pressure cooker. The simplest autoclaves (so-called "stovetop autoclaves") are largely indistinguishable from pressure cookers used in food preparation. Autoclaves are most commonly used before surgical procedures to sterilize medical instruments and supplies. This is accomplished by subjecting these items to pressurized saturated steam at at a gauge pressure of for 15 to 60 minutes (or longer), depending on the size, density, and contents of the load.

Industrial autoclaves are used in industrial applications, especially in the manufacturing of composites. Autoclaves are also commonly used in the chemical industry to cure coatings, vulcanize rubber, and for hydrothermal synthesis.…

An autoclave is a machine used to carry out industrial and scientific processes requiring elevated temperature and pressure in relation to ambient pressure and temperature. Autoclaves are found in many medical settings, laboratories, and other places that need to ensure the sterility of an object. The autoclave was invented by Charles Chamberland in 1879, although a precursor known as the steam digester was created by Denis Papin in 1679. The name comes from Greek auto-, meaning "self", and Latin clavis meaning "key", thus a self-locking device.

All autoclaves operate according to the same fundamental principles as a kitchen pressure cooker. The simplest autoclaves (so-called "stovetop autoclaves") are largely indistinguishable from pressure cookers used in food preparation. Autoclaves are most commonly used before surgical procedures to sterilize medical instruments and supplies. This is accomplished by subjecting these items to pressurized saturated steam at at a gauge pressure of for 15 to 60 minutes (or longer), depending on the size, density, and contents of the load.

Industrial autoclaves are used in industrial applications, especially in the manufacturing of composites. Autoclaves are also commonly used in the chemical industry to cure coatings, vulcanize rubber, and for hydrothermal synthesis. Flexible "research-grade" autoclaves are used in a wide range of research and industrial tasks, including quality control and quality assurance for food and beverage production, biomedical and pharmaceutical research and development, and product testing.

In research

Autoclaves are used in research and education to sterilize lab instruments and glassware, process waste loads prior to disposal, prepare culture media and liquid media, and artificially age materials for testing. They play a prominent role in biomedical research, pharmaceutical research, and industrial R&D. Research autoclaves display a wide range of designs and sizes, and may be tailored to their use and load type.

Common variations include either a cylindrical or square pressure chamber, air- or water-cooling systems, air-ballast systems (to prevent burst containers or boil-over when sterilizing liquids), and vertically or horizontally opening chamber doors (which may be electrically or manually powered). Research-grade autoclaves may be configured for "pass-through" operation. This makes it possible to maintain absolute isolation between "clean" and potentially contaminated work areas.

Pass-through research autoclaves are especially important in BSL-3 or BSL-4 facilities. Autoclaves not intended for use in a medical setting may be referred to as "research-grade" autoclaves. These are specifically designed for non-medical applications. Research autoclaves use a “jacketless” design where steam is generated directly in the pressure chamber using heating coils (rather than relying on a “steam jacket” and independent steam generator, as is the case in high-throughput medical autoclaves).

Research-grade autoclaves do not have to meet stringent requirements associated with sterilizing instruments that will be directly used on humans. Instead they can prioritize efficiency, programming flexibility, ease-of-use, and sustainability. The added cost of using a medical autoclave in a non-medical setting can be significant. For a 2016 study, the Office of Sustainability at the University of California, Riverside (UCR) tracked the power and water consumption of medical-grade and research-grade autoclaves performing similar research-related tasks.

Even when functioning within intended parameters, the medical-grade autoclaves consumed 700 gallons of water and 90 kWh of electricity per day (1,134MWh of electricity and 8.8 million gallons of water per year). UCR's research-grade autoclaves performed the same tasks with equal effectiveness, but used 83% less energy and 97% less water.

The University of Alabama at Birmingham (UAB) completed a similar study in 2023 comparing similar-sized jacketed (i.e., "medical") and non-jacketed (i.e., "research") autoclaves performing identical cycles indicative of the most common load and sterilization tasks used by their researchers. UAB found that jacketed autoclaves consumed significantly more water (44–50 gallons per cycle) and house steam (25–41 pounds per cycle) than non-jacketed autoclaves, which used less than 2 gallons of water and no house steam per cycle.

The higher water use by jacketed autoclaves resulted in an estimated water cost of $764 per jacketed autoclave per year, compared to $23 for non-jacketed autoclaves. With over 100 steam-jacketed autoclaves on campus, the author calculated that using jacketed autoclaves for research tasks translated into an additional $74,000 in annual excess spending for UAB. Jacketed autoclaves also had a higher initial purchase price (37% more than non-jacketed equivalents).

Quality assurance

bags often have a "sterilization indicator mark" that typically darkens when the bag and its contents have been adequately processed. Comparing the marks on an unprocessed bag (left) and on a bag that has been properly cycled (right) will reveal an obvious visual difference. In order to sterilize items effectively, it is important to use optimal parameters when running an autoclave cycle.

A 2017 study performed by the Johns Hopkins Hospital biocontainment unit tested the ability of pass-through autoclaves to decontaminate loads of simulated biomedical waste when run on the factory default setting. The study found that 18 of 18 (100%) mock patient loads (6 PPE, 6 linen, and 6 liquid loads) passed sterilization tests with the optimized parameters compared to only 3 of 19 (16%) mock loads that passed with use of the factory default settings.

There are physical, chemical, and biological indicators that can be used to ensure that an autoclave reaches the correct temperature for the correct amount of time. If a non-treated or improperly treated item can be confused with a treated item, then there is the risk that they will be mixed up, which is critical in areas such as surgery. Chemical indicators on medical packaging and autoclave tape change color once the correct conditions have been met, indicating that the object inside the package, or under the tape, has been appropriately processed.

Autoclave tape is only a marker that steam and heat have activated the dye. The marker on the tape does not indicate complete sterility. A more difficult challenge device, named the Bowie-Dick device after its inventors, is also used to verify a full cycle. This contains a full sheet of chemical indicator placed in the center of a stack of paper. It is designed specifically to prove that the process achieved full temperature and time required for a normal minimum cycle of 134 °C for 3.5–4 minutes. To prove sterility, biological indicators are used.

Biological indicators contain spores of a heat-resistant bacterium, Geobacillus stearothermophilus. If the autoclave does not reach the right temperature, the spores will germinate when incubated and their metabolism will change the color of a pH-sensitive chemical. Some physical indicators consist of an alloy designed to melt only after being subjected to a given temperature for the relevant holding time. If the alloy melts, the change will be visible. Some computer-controlled autoclaves use an F 0 (F-nought) value to control the sterilization cycle.

F 0 values are set for the number of minutes of sterilization equivalent to at above atmospheric pressure for 15 minutes. Since exact temperature control is difficult, the temperature is monitored, and the sterilization time adjusted accordingly.

Additional images

Image:Autoclave stove top.jpg|Stovetop autoclaves, also known as pressure cooker—the simplest of autoclaves Image:Autoclave Techna.jpg|Techna - 1987, used in food industry File:Autoclave machine.jpg|The machine on the right is an autoclave used for processing substantial quantities of laboratory equipment prior to reuse, and infectious material prior to disposal. (The machines on the left and in the middle are washing machines.) File:Systec H-Series Autoclaves.jpg|Horizontal high-capacity autoclave with cylindrical chamber File:Pass-through-autoclaves-1-231x300.jpg|Illustration of a cylindrical-chamber pass-through autoclave