. The meter communicates to its collection point using 900 MHz mesh network topology. Automatic meter reading (AMR) is the technology of automatically collecting consumption, diagnostic, and status data from water meter or energy metering devices (gas, electric) and transferring that data to a central database for billing, troubleshooting, and analyzing. This technology mainly saves utility providers the expense of periodic trips to each physical location to read a meter. Another advantage is that billing can be based on near real-time consumption rather than on estimates based on past or predicted consumption. This timely information coupled with analysis can help both utility providers and customers better control the use and production of electric energy, gas usage, or water consumption. AMR technologies include handheld, mobile and network technologies based on telephony platforms (wired and wireless), radio frequency (RF), or powerline transmission.
. The meter communicates to its collection point using 900 MHz mesh network topology. Automatic meter reading (AMR) is the technology of automatically collecting consumption, diagnostic, and status data from water meter or energy metering devices (gas, electric) and transferring that data to a central database for billing, troubleshooting, and analyzing. This technology mainly saves utility providers the expense of periodic trips to each physical location to read a meter. Another advantage is that billing can be based on near real-time consumption rather than on estimates based on past or predicted consumption. This timely information coupled with analysis can help both utility providers and customers better control the use and production of electric energy, gas usage, or water consumption. AMR technologies include handheld, mobile and network technologies based on telephony platforms (wired and wireless), radio frequency (RF), or powerline transmission.
Technologies
Touch technology
With touch-based AMR, a meter reader carries a handheld computer or data collection device with a wand or probe. The device automatically collects the readings from a meter by touching or placing the read probe close to a reading coil enclosed in the touchpad. When a button is pressed, the probe sends an interrogate signal to the touch module to collect the meter reading. The software in the device matches the serial number to one in the route database, and saves the meter reading for later download to a billing or data collection computer. Since the meter reader still has to go to the site of the meter, this is sometimes referred to as "on-site" AMR. Another form of contact reader uses a standardized infrared port to transmit data. Protocols are standardized between manufacturers by such documents as ANSI C12.18 or IEC 61107.
Radio frequency network
Radio frequency based AMR can take many forms. The more common ones are handheld, mobile, satellite and fixed network solutions. There are both two-way RF systems and one-way RF systems in use that use both licensed and unlicensed RF bands. In a two-way or "wake up" system, a radio signal is normally sent to an AMR meter's unique serial number, instructing its transceiver to power-up and transmit its data. The meter transceiver and the reading transceiver both send and receive radio signals. In a one-way "bubble-up" or continuous broadcast type system, the meter transmits continuously and data is sent every few seconds. This means the reading device can be a receiver only, and the meter a transmitter only. Data travels only from the meter transmitter to the reading receiver. There are also hybrid systems that combine one-way and two-way techniques, using one-way communication for reading and two-way communication for programming functions. RF-based meter reading usually eliminates the need for the meter reader to enter the property or home, or to locate and open an underground meter pit. The utility saves money by increased speed of reading, has less liability from entering private property, and has fewer missed readings from being unable to access the meter. The technology based on RF is not readily accepted everywhere. In several Asian countries, the technology faces a barrier of regulations in place pertaining to use of the radio frequency of any radiated power. For example, in India the radio frequency which is generally in ISM band is not free to use even for low power radio of 10 mW. The majority of manufacturers of electricity meters have radio frequency devices in the frequency band of 433/868 MHz for large scale deployment in European countries. The frequency band of 2.4 GHz can be now used in India for outdoor as well as indoor applications, but few manufacturers have shown products within this frequency band. Initiatives in radio frequency AMR in such countries are being taken up with regulators wherever the cost of licensing outweighs the benefits of AMR.
Brief history
In 1972, Theodore George "Ted" Paraskevakos, while working with Boeing in Huntsville, Alabama, developed a sensor monitoring system which used digital transmission for security, fire and medical alarm systems as well as meter reading capabilities for all utilities. This technology was a spin-off of the automatic telephone line identification system, now known as caller ID. In 1974, Paraskevakos was awarded a U.S. patent for this technology. In 1977, he launched Metretek, Inc., which developed and produced the first fully automated, commercially available remote meter reading and load management system. Since this system was developed pre-Internet, Metretek utilized the IBM series 1 mini-computer. For this approach, Paraskevakos and Metretek were awarded multiple patents. The primary driver for the automation of meter reading is not to reduce labor costs, but to obtain data that is difficult to obtain. As an example, many water meters are installed in locations that require the utility to schedule an appointment with the homeowner in order to obtain access to the meter. In many areas, consumers have demanded that their monthly water bill be based on an actual reading, instead of (for example) an estimated monthly usage based on just one actual meter reading made every 12 months. Early AMR systems often consisted of walk-by and drive-by AMR for residential customers, and telephone-based AMR for commercial or industrial customers. What was once a need for monthly data became a need for daily and even hourly readings of the meters. Consequently, the sales of drive-by and telephone AMR has declined in the US, while sales of fixed networks has increased. The US Energy Policy Act of 2005 asks that electric utility regulators consider the support for a "...time-based rate schedule (to) enable the electric consumer to manage energy use and cost through advanced metering and communications technology." The trend now is to consider the use of advanced meters as part of an advanced metering infrastructure.
Benefits of advanced metering
Advanced metering systems can provide benefits for utilities, retail providers and customers. Benefits will be recognized by the utilities with increased efficiencies, outage detection, tamper notification and reduced labor cost as a result of automating reads, connections and disconnects. Retail providers will be able to offer new innovative products in addition to customizing packages for their customers. In addition, with the meter data being readily available, more flexible billing cycles would be available to their customers instead of following the standard utility read cycles. With timely usage information available to the customer, benefits will be seen through opportunities to manage their energy consumption and change from one REP to another with actual meter data. Because of these benefits, many utilities are moving towards implementing some types of AMR solutions. In many cases, smart metering is required by law (e.g. Pennsylvania's Act 129 (2008)). The benefits of smart metering for the utility. Accurate meter reading, no more estimates Improved billing Accurate profile classes and measurement classes, true costs applied Improved security and tamper detection for equipment Energy management through profile data graphs Less financial burden correcting mistakes Less accrued expenditure Transparency of "cost to read" metering Improved procurement power though more accurate data — "de-risking" price In cases of shortages, utility will be able to manage/allocate supply. The benefits of smart metering for the customer. Improved billing and tracking of usage.
Disadvantages of advanced metering
Risk of loss of privacy — details of use reveal information about user activities Greater potential for monitoring by other/unauthorized third parties Potentially reduced reliability (more complicated meters, more potential for interference by third parties) Increased security risks from network or remote access
References
External links