A binary cycle is a method for generating electrical power from geothermal resources and employs two separate fluid cycles, hence binary cycle. The primary cycle extracts the geothermal energy from the reservoir, and secondary cycle converts the heat into work to drive the generator and generate electricity.

Binary cycles permit electricity generation even from low temperature geothermal resources (<180 °C) that would otherwise produce insufficient quantities of steam to make flash power plants economically viable. However, due to the lower temperatures binary cycles have low overall efficiencies of about 10–13%.

A binary cycle is a method for generating electrical power from geothermal resources and employs two separate fluid cycles, hence binary cycle. The primary cycle extracts the geothermal energy from the reservoir, and secondary cycle converts the heat into work to drive the generator and generate electricity.

Binary cycles permit electricity generation even from low temperature geothermal resources ( \dot{W}_\text{turbine} = \dot{m}_\text{wf} * \eta_\text{turbine}*(h_1 - h_\text{2s}) \dot{W}_\text{turbine} is the rate of work done by the turbine, in kW \dot{m}_\text{wf} is the mass flow rate of working fluid, in kg/s \eta_\text{turbine} is the turbine efficiency, non-dimensional h_1 is the specific enthalpy of the working fluid at the turbine inlet, in kJ/kg h_\text{2s} is the specific enthalpy of the working fluid at the turbine outlet, assuming isentropic expansion in the turbine, in kJ/kg \dot{Q}_\text{condenser} = \dot{m}_\text{wf} *(h_2 - h_3) = \dot{m}_\text{coolant} *(h_y - h_x) \dot{Q}_\text{condenser} is the rate of heat removed from the working fluid in the condenser, in kW h_2 and h_3 are the specific enthalpy of the working fluid at the condenser inlet and outlet respectively, in kJ/kg \dot{m}_\text{coolant} is the mass flow rate of coolant, in kg/s h_x and h_y are the specific enthalpy of coolant at the condenser inlet and outlet respectively, in kJ/kg \dot{W}_\text{pump} = \dot{m}_\text{wf} * (h_\text{4s} - h_3)/\eta_\text{pump} \dot{W}_\text{pump} is the rate of work done by the pump to repressurise the working fluid, in kW h_\text{4s} is the specific enthalpy of the working fluid at the feed pump outlet, assuming isentropic compression, in kJ/kg h_3 is the specific enthalpy of the working fluid at the feed pump inlet, in kJ/kg \eta_\text{pump} is the pump efficiency, non-dimensional \dot{Q}_\text{PHX} = \dot{m}_\text{wf} *(h_1 - h_4) = \dot{m}_\text{geofluid} *(h_a - h_c) \dot{Q}_\text{PHX} is the rate of heat added to the working fluid within the primary heat exchanger, kW h_4 is the specific enthalpy of the working fluid at the primary heat exchanger inlet, in kJ/kg \dot{m}_\text{geofluid} is the mass flow rate of geofluid, in kg/s h_a and h_c are the specific enthalpy of the geofluid at the primary heat exchanger inlet and outlet respectively, in kJ/kg \eta_\text{I}^\text{th} = \frac{\dot{W}_\text{net}}{\dot{Q}_\text{PHE}} = \frac{\dot{W}_\text{turbine}-\dot{W}_\text{pump}}{\dot{Q}_\text{PHE}} \eta_\text{Carnot} = 1-\frac{T_C}{T_H} T_C and T_H are the hot and cold absolute temperature respectively, in K \eta_\text{II}^\text{util} = \frac{\dot{W}_\text{net}}{\dot{E}_\text{geofluid}} = \frac{\dot{W}_\text{turbine}-\dot{W}_\text{pump}}{\dot{m}_\text{geofluid}*[(h_a - h_0)-T_0*(s_a-s_0)]} \dot{E}_\text{geofluid} is the exergy rate of geofluid, in kW. h_0 , s_0 and T_0 are the specific enthalpy, in kJ/kg, the specific entropy, in kJ/kg/K and the absolute temperature, in K, of the geofluid at the local reference condition. This could be local ambient, wet-bulb or reinjection conditions.

Working fluid selection

The working fluid plays a pivotal role in any binary cycle and must be selected with care. Some criteria for selecting a suitable fluid are given below. A critical temperature and pressure above the cycle maximum temperature and pressure – most of the heat is transferred at the maximum temperature, increasing efficiency.

A saturation dome that resembles an inverted U – this prevents liquid drop out in the turbine, which reduces efficiency, damages the turbine blades and thus reduces the turbine's lifetime. High thermal conductivity – improves the heat transfer in the primary heat exchanger and the condenser, reducing the total heat transfer area required and therefore cost of the plant.

Environmental compatibility – non-toxic, non-carcinogenic, low global warming potential, low ozone depletion potential, non-flammable, chemically inert. Low cost and readily available.

See also

Geothermal electricity Working fluid Organic Rankine cycle Kalina cycle

Text derived from https://en.wikipedia.org/w/index.php?oldid=1367898407 under CC BY-SA 4.0; modifications have been made.

Provenance

snapshot enwiki-001367898407 · captured 1785957627.0 · version history

Cite this page as: encyclopegia.org, “Binary cycle”, snapshot enwiki-001367898407. https://encyclopegia.org/a/binary-cycle

Sources cited in this revision

7 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.