Caesium standard
used as part of an atomic clock The caesium standard is a primary frequency standard in which the photon absorption by transitions between the two hyperfine ground states of caesium-133 atoms is used to control the output frequency.
≈ 8 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
used as part of an atomic clock The caesium standard is a primary frequency standard in which the photon absorption by transitions between the two hyperfine ground states of caesium-133 atoms is used to control the output frequency. The first caesium clock was built by Louis Essen in 1955 at the National Physical Laboratory in the UK and promoted worldwide by Gernot M. R. Winkler of the United States Naval Observatory.
Caesium atomic clocks are one of the most accurate time and frequency standards, and serve as the primary standard for the definition of the second in the International System of Units (SI), the modern metric system. By definition, radiation produced by the transition between the two hyperfine ground states of caesium-133 (in the absence of external influences such as the Earth's magnetic field) has a frequency, , of exactly .
That value was chosen so that the caesium second equaled, to the limit of measuring ability in 1960 when it was adopted, the existing standard ephemeris second based on the Earth's orbit around the Sun. Because no other measurement involving time had been as precise, the effect of the change was less than the experimental uncertainty of all existing measurements.…
used as part of an atomic clock The caesium standard is a primary frequency standard in which the photon absorption by transitions between the two hyperfine ground states of caesium-133 atoms is used to control the output frequency. The first caesium clock was built by Louis Essen in 1955 at the National Physical Laboratory in the UK and promoted worldwide by Gernot M. R. Winkler of the United States Naval Observatory.
Caesium atomic clocks are one of the most accurate time and frequency standards, and serve as the primary standard for the definition of the second in the International System of Units (SI), the modern metric system. By definition, radiation produced by the transition between the two hyperfine ground states of caesium-133 (in the absence of external influences such as the Earth's magnetic field) has a frequency, , of exactly .
That value was chosen so that the caesium second equaled, to the limit of measuring ability in 1960 when it was adopted, the existing standard ephemeris second based on the Earth's orbit around the Sun. Because no other measurement involving time had been as precise, the effect of the change was less than the experimental uncertainty of all existing measurements. While the second is the only base unit to be explicitly defined in terms of the caesium standard, the majority of SI units have definitions that mention either the second, or other units defined using the second.
Consequently, every base unit except the mole and every named derived unit except the coulomb, gray, sievert, radian, and steradian have values that are implicitly at least partially defined by the properties of the caesium-133 hyperfine transition radiation. And of these, all but the mole, the coulomb, and the dimensionless radian and steradian are implicitly defined by the general properties of electromagnetic radiation.
Note that a common confusion involves the conversion from angular frequency ( \omega ) to frequency ( f ), or vice versa. Angular frequencies are conventionally given as s −1 in scientific literature, but here the units implicitly mean radians per second. In contrast, the unit Hz should be interpreted as cycles per second.
The conversion formula is \omega = 2\pi f , which implies that 1 Hz corresponds to an angular frequency of approximately 6.28 radians per second (or 6.28 s −1 where radians is omitted for brevity by convention). 1 second, s, = 9,192,631,770 1 hertz, Hz, = 1/s = 1 becquerel, Bq, = 1 nuclear decay/s = nuclear decays/ This also linked the definitions of the derived units relating to force and energy (see below) and of the ampere, whose definition at the time made reference to the newton, to the caesium standard.
Before 1967 the SI units of time and frequency were defined using the tropical year and before 1960 by the length of the mean solar day 1 metre, m, = = c = 1 radian, rad, = 1 m/m = / = 1 (dimensionless unit of angle) 1 steradian, sr, = 1 m 2 /m 2 = 2 / 2 = 1 (dimensionless unit of solid angle) Between 1960 and 1983, the metre had been defined by the wavelength of a different transition frequency associated with the krypton-86 atom. This had a much higher frequency and shorter wavelength than the caesium standard, falling inside the visible spectrum.
The first definition, used between 1889 and 1960, was by the international prototype meter. c = 299,792,458 m/s h = J s The caesium-133 hyperfine transition radiation was explicitly defined to have frequency: = 9,192,631,770 Hz Though the above values for c and were already obviously implicit in the definitions of the metre and second. Together they imply: = = = c = m = h = 9,192,631,770 Hz × = = = = kg Notably, the wavelength has a fairly human-sized value of about 3.26 centimetres and the photon energy is surprisingly close to the average molecular kinetic energy per degree of freedom per kelvin.
From these it follows that: 1 kilogram, kg, = 1 joule, J, = 1 watt, W, = 1 J/s = 1 newton, N, = 1 J/m = / 1 pascal, Pa, = 1 N/m 2 = / 3 1 gray, Gy, = 1 J/kg = / = 1 sievert, Sv, = the ionizing radiation dose equivalent to 1 gray of gamma rays Prior to the revision, between 1889 and 2019, the family of metric (and later SI) units relating to mass, force, and energy were somewhat notoriously defined by the mass of the International Prototype of the Kilogram (IPK), a specific object stored at the headquarters of the International Bureau of Weights and Measures in Paris, meaning that any change to the mass of that object would have resulted in a change to the size of the kilogram and of the many other units whose value at the time depended on that of the kilogram. 1 kelvin, K, = J/2 per degree of freedom = per degree of freedom = per degree of freedom Temperature in degrees Celsius, °C, = temperature in kelvins − 273.15 = 1 mole, mol, = elementary entities 1 katal, kat, = 1 mol/s = elementary entities/ 1 coulomb, C, = e 1 ampere, or amp, A, = 1 C/s = e 1 volt, V, = 1 J/C = /e 1 farad, F, = 1 C/V = e 2 / 1 ohm, Ω, = 1 V/A = / e 2 = h/e 2 1 siemens, S, = 1/Ω = e 2 /h 1 weber, Wb, = 1 V s = /e = h/e 1 tesla, T, = 1 Wb/m 2 = /e 2 = E/e c 1 henry, H, = Ω s = h /e 2 Photon energy: Hz × J s = J luminous efficacy, K CD , = 683 lm/W luminous energy per photon, Q_\mathrm v , = J × 683 lm/W = lm s This implies: 1 lumen, lm, = Q_\mathrm v 1 candela, cd, = 1 lm/sr = Q_\mathrm v /sr 1 lux, lx, = 1 lm/m 2 = Q_\mathrm v / 2 Frequency = 9,192,631,770 Hz Time period = s Wavelength = m Photon energy = J Photon mass equivalent = kg If the seven base units of the SI are expressed explicitly in terms of the SI defining constants, they are: 1 second = 1 metre = c/ 1 kilogram = h /c 2 1 ampere = e 1 kelvin = h /k 1 mole = elementary entities 1 candela = h 2 K CD /sr Ultimately, 6 of the 7 base units (all but the dimensionless mole) notably have values that depend on that of , which appears far more often than any of the other defining constants.
However, the derived unit of one coulomb, which is an ampere-second, is a dimensionful unit defined purely in terms of the elementary charge and hence is independent of .
Text derived from https://en.wikipedia.org/w/index.php?oldid=1328818072 under CC BY-SA 4.0; modifications have been made.