In control theory, a closed-loop transfer function is a mathematical function describing the net result of the effects of a feedback control loop on the input signal to the plant under control.
Overview
edit edit sourceThe closed-loop transfer function is measured at the output. The output signal can be calculated from the closed-loop transfer function and the input signal. Signals may be waveforms, images, or other types of data streams.
An example of a closed-loop block diagram, from which a transfer function may be computed, is shown below:
The summing node and the G(s) and H(s) blocks can all be combined into one block, which would have the following transfer function:
- Y(s)X(s)=G(s)1+G(s)H(s)
G(s) is called the feed forward transfer function, H(s) is called the feedback transfer function, and their product G(s)H(s) is called the open-loop transfer function.
Derivation
edit edit sourceWe define an intermediate signal Z (also known as error signal) shown as follows:
Using this figure we write:
- Y(s)=G(s)Z(s)
- Z(s)=X(s)−H(s)Y(s)
Now, plug the second equation into the first to eliminate Z(s):
- Y(s)=G(s)[X(s)−H(s)Y(s)]
Move all the terms with Y(s) to the left hand side, and keep the term with X(s) on the right hand side:
- Y(s)+G(s)H(s)Y(s)=G(s)X(s)
Therefore,
- Y(s)(1+G(s)H(s))=G(s)X(s)
- ⇒Y(s)X(s)=G(s)1+G(s)H(s)
See also
edit edit source- Federal Standard 1037C
- Open-loop controller
- Control theory § Open-loop and closed-loop (feedback) control
References
edit edit source- This article incorporates public domain material from Federal Standard 1037C. General Services Administration. Archived from the original on 2022-01-22.
properties
- Bode plot
- Block diagram
- Closed-loop transfer function
- Controllability
- Fourier transform
- Frequency response
- Laplace transform
- Negative feedback
- Observability
- Performance
- Positive feedback
- Root locus method
- Servomechanism
- Signal-flow graph
- State-space representation
- Stability theory
- Steady state analysis & design
- System dynamics
- Transfer function
control
techniques
- Artificial neural network
- Coefficient diagram method
- Control reconfiguration
- Distributed parameter system
- Fractional-order control
- Fuzzy logic
- H-infinity loop-shaping
- Hankel singular value
- Kalman filter
- Krener's theorem
- Least squares
- Lyapunov stability
- Minor loop feedback
- Perceptual control theory
- State observer
- Vector control
applications
- Automation and Remote Control
- Distributed control system
- Electric motors
- Industrial control system
- Mechatronics
- Motion control
- Process control
- Robotics
- Supervisory control and data acquisition (SCADA)
Text derived from https://en.wikipedia.org/w/index.php?oldid=1358729021 under CC BY-SA 4.0; modifications have been made.