Coil winding technology
In electrical engineering, coil winding is the manufacture of electromagnetic coils.
≈ 28 min read
Coil winding technology. encyclopegia.org, snapshot enwiki-001367652139. /a/coil-winding-technology
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
In electrical engineering, coil winding is the manufacture of electromagnetic coils. Coils are used as components of circuits, and to provide the magnetic field of motors, transformers, and generators, and in the manufacture of loudspeakers and microphones. The shape and dimensions of a winding are designed to fulfill the particular purpose.
Parameters such as inductance, Q factor, insulation strength, and strength of the desired magnetic field greatly influence the design of coil windings. Coil winding can be structured into several groups regarding the type and geometry of the wound coil. Mass production of electromagnetic coils relies on automated machinery.
Terminology related to electric machines
This article is about coil winding technology and much of the article is specific to electric machines. This section provides definitions of terms used later in the article.
Rotor and stator
An electric motor or generator consists of a cylinderical rotating part called the rotor and a stationary part called the stator. For maximum efficiency, a gap between the rotor and stator is kept as small as possible, typically 1–2 mm. For most AC generators, the stator acts as the armature, and the rotor acts as the field magnet.
Laminations
The rotor and stator are both assembled from a stack of laminations stamped from sheets of electrical steel, typically 1 mm thick. The laminations are designed to minimize eddy currents, which would otherwise waste energy and create heat.
Slots and teeth
Windings consist of insulated conductors, which pass through slots cut along the axis of the stator. The spaces between the slots are called teeth. The shape of the slots and teeth depends upon the design of the electric machine.
Slots may be rectangular, they may taper, they may be circular, etc. The wider part at the end of the tooth is called a tooth shoe. Some authors use the term "groove" to mean the same thing as slot. In this article, the term groove refers to the indentations between parallel conductors in a layer of a winding.
Poles
Pole means magnetic pole, and poles always come in pairs, usually referred to as "North" and "south." Poles may be physical objects in fixed places, or poles may be virtual objects moving as the machine operates. A pole may be a single piece of magnetic material, or a pole may be distributed over multiple teeth.
Electrical degrees
A rotor makes a complete rotation in 360 degrees. That amounts to 180 degrees to pass by each pole of a two pole machine. The current in conductors also goes through a complete cycle in 360 degrees.
For a four pole machine, each pole spans only 90 degrees. During the 90 degrees the current in a conductor goes through a half cycle, or 180 degrees. Because there are four poles, and 4 × 180 = 720, the conductors go through two complete cycles for each complete turn of the rotor.
To distinguish between the mechanical movement of the rotor, and electrical activity in conductors, the terms mechanical degrees and electrical degrees are used. mechanical degrees indicate the amount the rotor has turned about its shaft. electrical degrees indicate the amount the currents in conductors has changed. In general, electrical degrees equals mechanical degrees times 1/2 the number of poles.
No matter how many poles, each pole always spans exactly 180 electrical degrees, and it is called pole pitch. Electrical degrees and mechanical degrees are related as follows: \text{electrical degrees} = \frac{P }{2}\cdot \text{mechanical degrees} where P is the number of poles.
F = \frac{d^2 \cdot \frac{\pi}{4}\cdot n }{b\cdot h} d - Wire gauge including the varnish insulation n - Number of windings b \cdot h - Cross section of the coil body Dense packing of wires reduces air space, and is said to have a high fill factor. This increases the efficiency of the electrical device and an improved heat conductivity of the winding.
For best packing of round wires on a multi-layer winding, the wires in the upper layer are in the grooves of the lower layer for at least 300 degrees of the coil circumference. The wires occupy a dense package which is called “orthocyclic winding”. The opposite of this would be a random wire structure within the winding space, which is called “wild winding.”
Wild winding
Also known as jumble winding, with this type of winding structure only poor fill factors can be achieved. The random wire placement leads to a wider distribution of resulting wire length on the coil body and consequently a wider range of electric coil resistances. Despite its disadvantages, it is common in mass production.
It is characterized by low demands for machinery and operator and can be wound with very high speeds. Wild windings are mostly applied in contactor- and relay coils, small transformers, Ignition coils, small electrical motors, and generally devices with relatively small wire gauges up to 0.05 mm.
Achieved fill factors with the use of round wires are about 73% to 80% and are lower compared to orthocyclic windings with 90%. The winding height can be estimated using the formula: h = d^2 \cdot \frac {n}{b} d - Wire gauge including the insulation n - Number of windings b - Width of winding h = [1+(n-1)\cdot \sin 60^\circ]\cdot d h -Winding height n - Number of layers d - max. wire gauge above the varnish (CuL) Since an orthocyclically wound coil with at least 300° of the circumference of winding layers has the tightest circle package of the wire cross-sections.
This winding method reaches the highest fill factor and is the best way to fill the available winding cross-section with round wires. Square coils are seen as orthocyclically wound when the winding and layer jump occur only on one of the sides of the winding cross-section. In theory, a geometric fill factor of 0.91 will be reached.
In practice, however, the value cannot be reached because there exists a winding jump and layer jump area and the wire insulation is not taken into account. A\Delta = \frac {d^2}{4} \cdot \sqrt{3} \Sigma A\Delta = \frac {d^2 \cdot \pi} {4} \cdot \frac {60}{360} \cdot 3 =\frac {d^2 \cdot \pi} {8} fill factor = \frac {\Sigma A\Delta}{A\Delta} = \frac {\frac {d^2 \cdot \pi}{8}} {\frac {d^2}{4} \cdot \sqrt{3}} = \frac {d^2 \cdot \pi}{8} \ \frac {1}{\frac {d^2}{4}\cdot \sqrt {3}} = \frac {\pi}{2 \cdot \sqrt {3}} = 0,907 In general, it can be stated that the requirements that need to be fulfilled for orthocyclic windings are very high.
The summation of all tolerances has to be kept at a very low value. Consequently, the following values can be named as indicatory values: a) Tolerance of the winding space width \Delta b= 0,2 \cdot d \Delta b - tolerance of winding space d - max. wire gauge including the varnish coat (CuL) b) Tolerance of the wire Max. wire diameter tolerance should not be larger than \Delta d = 0,4 \cdot \frac {d}{n} \Delta d - gauge – wire tolerance n - number of turns per layer d - nominal wire gauge including the varnish coat (CuL) This corresponds to about half the wire tolerance according to the specification of the German standard DIN46435.
Manufacturing orthocyclic windings
Even if the demands for low tolerances of the wire and the winding space had to be observed with correspondingly high technical effort, there would still remain the problem that the wire guiding on the machine side has to follow the previously described winding design also at high winding speeds. In practice, this is hardly possible at high winding speeds since, e.g., at 18.000 windings per minute, the wire guide for a wire with a thickness of 0.3 mm would need to perform a winding pitch in only 0.7 ms. The problem is amplified by the fact that in practice the ideal wire is never absolutely straight.
These unevennesses and bends resulting from the winding of the wire on delivery rolls have the effect that the wires are never completely close together according to their actual diameter but at a distance according to their unevenness. This gap formation is additionally influenced during the winding-up of the wire by the surface quality of its coating, e.g. the sliding behavior as well as by the expansion behavior or stiffness of the copper.
The wire elongation may be between 6% and 3% depending on the wire diameter and the supplier. Practice has shown that an orthocyclic winding can only be manufactured in an acceptable way when choosing a very high wire elongation level (stretching leads to a straight or even wire) at the beginning.
For the reasons described above, it is therefore in practice impossible for the wire guide to determine a precise gradient according to the wire diameter. These unpredictable circumstances may be prevented or counteracted at the beginning of the winding by forcing the wire, meaning, every single winding of the first layer on the inner coil diameter, into a predefined position.
The wire places itself into a prefabricated groove geometry of the coil body and the wire guide does not need to follow it exactly but only approximately. Since the wire always loses in cross-sectional area due to the wire drawing to be used and the necessary deflections (mechanical stresses under tensile load) during winding, the distance between the grooves is designed only for the max. possible wire diameter.
Effects of bends and tolerances of the wire and the coil body as well as changing surface qualities can be avoided that way. Especially wire bends that develop due to wire deflections caused by, e.g., pulleys, wire eyelets or even the wire guiding nozzle itself within the wire feeder of a winding machine can lead to deformations that remain on the winding of a coil.
Applying grooves to the winding basis supports the layer-accurate position of the wire during the winding process. This behavior is particularly beneficial for the winding processes where a plastic deformation of the wire is unavoidable immediately before the depositing of the wire onto the winding basis. This behavior can be observed especially in the needle winding technology.
Owing to physical reasons, it is unavoidable that the wire leaves the wire guiding nozzle at an angle of approx. 90°. Therefore, mechanical tensions remain inside the wire that are visible in the form of a bent winding on the winding basis. As a result, the following windings, or also the following layers, can change in their desired position.
Starting from the second layer, the relocation is facilitated, since the wire is guided through the inter-spaces of the preceding layer. In case of deflections that are not too excessive as far as the process is concerned, the wire leads itself and with a constant number of windings per layer.
It means for the wire guiding movement that the smaller the distance of the wire guiding nozzle towards the coil, the more precise the tracking must be. In certain circumstances it can be completely performed without a relocating movement, if the distance from the nozzle to the coil is that long that the force component against the guiding behavior of the wire itself has no longer an effect.
Owing to the self-guiding behavior of the wire, it is therefore possible that also during orthocyclic winding the wire guide can run continually and does not need to follow gradually.
Design of an orthocyclic winding
The design or interpretation of the required space of an orthocyclic winding is usually realized by applying an iterative approach. At first, the specified parameters of the required number of windings, the required wire cross section and the maximum space available for an insulated coil are used for the calculation basis.
Calculation example
An orthocyclic winding design for a round coil with 150 windings, a wire diameter of 0.3 mm and a maximum winding width of 9 mm shall be calculated. The winding diameter at the winding base measures 8 mm.
Given: Wire-Ø Cu 0,3 mm → CU1L=0,334 mm (According to the table) Coil width: should be 9 mm // 150 turns, coil inner diameter 8mm. a) Calculation of the winding width In the first iteration step, a winding with the same number of windings per layer is assumed or taken as a basis. 9/0,334 → 26,9 turns/layer → chosen 26 turns per layer Winding width = 26 \cdot 0.334 + 0.5 \cdot 0.334 = 8.85mm b) Calculation of the number of layers Number of layers = 150/26 = 5,76 → 6 layers c) Calculation of the winding height \text{Winding height h}= [1+(h-1) \cdot \sin 60^\circ] \cdot d \text{ Winding height h}= [1+(6-1) \cdot \sin 60^\circ] \cdot 0.334=1.78mm d) Calculation of the winding height in the layer cross section area h_\text{Lagensprung} = 1.78 + 5\% = 1.86mm e) Calculation of the outer diameter of the coil \text{Outer diameter }: D=2 \cdot h + inner diameter of winding D = 1.78\cdot 2 + 8 = 11.56mm f) Calculation of the outer dimensions of the coil in the cross section area \text{ Outer diameter }: D_\text{max}=2 \cdot h_\text{layer step} + inner diameter of winding D_\text{max}=1.86 \cdot 2+8=11.72mm Summary of results: The calculation showed that the space needed for the purely orthocyclic winding with enameled wire fills a rectangular area that measures 1.86 mm x 8.85 mm.
Taking into account the assumption that it is a round coil with an inner diameter of 8 mm, then, the outer diameter is 11.72 mm. The winding space constraints (flanges of a coil body) of a winding support must have a diameter of at least D min =11,72mm considering the layer jump area.
Calculation of the fill factor
The fill factor measures the ratio between the volume of a winding package and the volume needed to house the winding pack. For this purpose, it is necessary to take the required space for the rotation diameter of the coil in the "cross over section" into consideration. a) Calculation of the mechanical fill factor The imaginary space with the dimensions of 8,85 mm x 1,86 mm contains an area of 16.461 mm 2 .
The sum of all partial spaces of the insulated turns equals A=\frac{\pi \cdot D^2}{4} \cdot n A = Amount of partial spaces of the insulated wires D L = wire gauge above the varnish n= number of turns A=\frac{\pi \cdot 0.334^2}{4} \cdot 150 = 13.14mm^2 F_\text{mech}= A_\text{wire}/A_\text{Winding space} \cdot 100\% F_\text{mech}= 13.14mm^2 / 16.461 mm^2 \cdot 100\% F_\text{mech}= 79.8\% b) Calculation of the electrical fill factor The imaginary space with the dimensions of 8,85 mm x 1,86 mm contains an area of 16.461 mm 2 . The sum of all partial spaces of the not insulated turns equals A=\frac{\pi \cdot D^2}{4} \cdot n A= Amount of partial spaces of the not insulated wires D Cu = pure copper wire gauge n= number of turns A=\frac{\pi \cdot 0.3^2}{4} \cdot 150 = 10.59mm^2 F_\text{electr}= A_\text{ wire }/A_\text{ Winding space } \cdot 100\% F_\text{electr}= 10.59mm^2 / 16.461 mm^2 \cdot 100\% F_\text{electr}= 64.3\%
Needle winding
To efficiently wind narrow slots of electronically commutated multipole three-phase motors, the teeth are coated with insulation and directly wound with the needle winding method. A needle with a nozzle that is placed at a right angle to the direction of movement travels in a lifting motion passing the stator packs through the slot channel between the two neighboring teeth of the motor to drop the wire in the desired place.
The stator is then turned at the reversal point on the winding head by one tooth pitch so that the previous process can run again in reverse order. With this winding technology a specific layer structure can be realized. A disadvantage is that there must be a clearance between two adjacent teeth with a size of at least the nozzle diameter.
The nozzle diameter is about three times the diameter of the winding wire. The space between two adjacent teeth can therefore not be filled completely. An advantage is that the needle support carrying the wire guiding nozzle is normally coupled to a CNC coordinate system.
This allows moving the nozzle through space towards the stator. This way, it is possible to also perform a laying movement apart from the normal lifting motion and the rotation of the stator. A targeted placing of the wire is nevertheless only possible to a limited extend since the wire is pulled at an angle of 90° from the wire guiding nozzle resulting in an undefined bulging.
The 90° redirection of the wire when exiting the hollow needle stresses the wire a lot and makes it difficult to wind copper wires with a diameter of more than 1 mm in a reasonable way. Orthocyclic winding with a needle winder is therefore only partly possible for these winding tasks.
Since the wire guiding nozzle can be moved freely throughout the room, it is possible for the nozzle to terminate the wire at the contact points if equipped with an additional swivel device. As in the case of the conventional linear winding technology, a contact pin or a hook contact can be terminated for the electrical connection and for interconnecting the single poles in a star connection or delta connection.
A precise synchronization of the rotary motion with the stroke movement is required so that the needle does not touch the slot channel during the up and down movement. Influencing variables for the maximum winding speed are the needle stroke, the rotation angle of the stator (number of poles), the wire diameter and the slot channel width and the helix angle of the angularly slotted stators.
The mass of the wire guide and the needle support experience a high acceleration. This can lead to unwanted vibrations that have an effect on the winding quality. The lifting motion is normally generated by ball screws.
During this movement, the servo drives must constantly reverse in order to reverse the direction of the needle movement. Another way of initiating the stroke movement is to apply a crank disk that can also have a stroke adjustment and that uses the advantage of the sinusoidal movement pattern without needing a drive motor to reverse.
Strokes (windings) up to 2500 per minute can be achieved. With the needle winding technology, it is possible to produce a finished assembly such as stator coils or a connection and contacting onto a machine.
Apart from the not fully utilized space between the poles, it is possible – in contrast to the conventional pull-in technique – to wind also motor coils with a good fill factor onto low stator sheet stack heights (coiler head heights).
Toroidal core winding technology
With the toroidal core winding technology an electric coil or winding is created by winding an electrical conductor (e.g. copper wire) through the circular ring and evenly distributing it over the circumference (Toroidal inductors and transformers, toroidal chokes). Before the winding starts, the Toroidal / Magnetic core is mounted into a holding fixture that can initiate a slow rotary movement of the core with mostly three rubberized points of contact.
A wire storage ring (orbital wheel) arranged 90° to the toroidal core will now be opened at the circumference and introduced into the center of the toroidal core. The wire is then coiled around the wire storage ring that was closed again.
When the required amount is present on the wire accumulator, the end of the wire from the wire accumulator is fixed to the toroidal core that needs to be wound. By simultaneous rotation of the toroidal core and the wire accumulator ring, a winding develops that is distributed along the circumference of the toroidal core.
Upon completion, the wire accumulator has to be opened again in order to be able to remove the ready wound toroidal core. Since the start and end wire are often not fixable to the toroidal core, toroidal winding machines can only be partly automated.
Toroidal cores are used despite the high manufacturing costs (a great deal of manual work) due to the low magnetic flux leakage (MFL – Leakage inductance), low core losses and the good power density. One possible quality feature of transformers is a uniform distribution of the windings along the circumference (low stray field).
The insulation between the various windings can be solved quite differently. In case of covering windings, a film is applied after the first winding to achieve good stray field characteristics. This film needs to be wound to cover the whole circumference.
For this, also toroidal winding machines with special magazines can be used.
Trends in motor winding technology
Because of the higher performance density, brushless EC drives (electronically commutated motors) with permanent magnet rotors are increasingly used instead of the asynchronous technology. Owing to the compact design, the copper content can be cut in half in the best-case scenario. The manufacturers of electric motors also demand more flexibility of the production technology.
For producing asynchronous motors, drawing-in systems are usually used that are initially winding air-core coils only to draw them later into the stator with a tool. In contrast, the concentrated winding of EC stators is more flexible in the manufacturing process, energy saving when implemented, better adjustable during operation and it requires less space.
Hairpin winding
A hairpin winding replaces many thin flexible round conductors with single thick flat rigid rectangular conductors to improve fill-rate. The thick conductors have sharp bends, resembling hairpin turn. Each hairpin occupies only two slots.
The hairpins are welded together to form a continuous circuit through many slots. Hairpin winding has been widely used in electric motors in the automotive sector. This winding method offers the advantage of automated winding process.
Because of skin effect the large size of the conductors are prone to proximity losses resulting in high winding AC loss but because of the lower DC resistance, the copper losses are lower. The result when compared to random winding is higher efficiency at high load and low speed and lower efficiency at low load and high speed.
Similar method, plug-in winding, has been proposed where the coils are pre-made with plug-in features (male-female). Compared to hairpin, the plug-in method offers the advantages of automated winding process and small conductors size, however, the disadvantage of high contact resistivity in the plug-in connectors could result in a thermal hot spots.
Manufacturing process of distributed winding
Asynchronous motors with distributed winding account for the major share of electric motors. Unlike the concentrated winding, not every tooth pole is wound in a distributed winding; instead, coils are in slots and span multiple pole teeth. Since the winding may block slots from further insertion of wire, it may be necessary to wind a complete phase winding at one time.
Coil insertion machines insert prefabricated groups of coils into the stators of electric motors. The coil groups are frequently manufactured with flyer winding machines and put onto the insertion tool with a transfer instrument. In small-batch manufacturing, the coil groups are relocated manually from the winding masks to the insertion tool using transfer instruments.
Subsequently, an insertion tool places the preformed winding into the stator slots. The slots are sometimes insulated with paper. When diagonally winding the coil into the slot of the stator, the coil's internal width must be larger than the stator's height which leads to the formation of the large winding head that is characteristic for the insertion technique.
This in turn results in a relatively loose winding in the stator slots. Consequently, it is necessary to close the slot openings towards the middle of the stator with a sliding cover. In many cases, this may be conducted concurrently with the insertion of the coils.
Since the coil's conductors have to pass through an oftentimes tight slot, the coils consist of a certain number of small spare cross-sections which are later connected in parallel. It is with this measure, that large conductor cross-sections may also be produced. Another reason for using many thin conductors connected in parallel lies in avoiding the Skin effect.
In order to keep the impact of this effect as small as possible, wires with the largest possible surface are used in high-frequency technology, e.g. in the form of thin spare cross-sections or Litz wires. The low losses of Litz wires partly stem from the fact that a large area of the inner surface is taking part in the current flow.
In particular in electric mobility, the motor is often powered by high-frequency voltage. When using large conductor cross-sections, this may possibly lead to high losses and an undesired heat development in the stator winding. After inserting the winding, rework on the stator or the winding ends needs to be performed.
Usually, the multitude of connecting lines is separated manually and bundled according to the different phases. Both winding ends are tied up with an adhesive tape or strap in the further course of the finishing. When using a high operating voltage, the partial winding of each phase must be insulated against the respective adjacent phase with foil or insulation paper.
To ensure that the winding heads are positioned exclusively at the back of the stator, both of them must be moulded. This is either executed by using an enameled wire receiving a bonding electric current during moulding or by cold forming which is followed by impregnation.
The creation of a certain winding head shape allows a rotor to be installed or a stator to be inserted into the housing afterwards. q=\frac{N}{2p\cdot m} , where: q = Number of holes N = Number of slots 2p = Number of poles m = Number of phases In the case of distributed windings, q ≥ 1, and if q is integer, it is an integral slot winding. If q = zq/nq is a fractional rational number, it is referred to as fractional slot winding.
When it comes to single tooth winding, q q=\frac{60}{2 \cdot 5 \cdot 3} = 2
Manufacturing process of concentrated windings for stator coils
Manufacturing stator windings in a concentrated manner can be performed in various ways. The choice of the respective winding process is primarily based on the design and setup of the stator as well as the commercial aspects. Most stators are designed in a way that allows the application of different winding processes.
The stator construction of the full-metal cut which is internally slotted constitutes the only exception. This construction can solely be manufactured by applying the needle-winding technique and in some rare cases the insertion technique for concentrated windings.
Most concentrated windings are executed as double-layer windings, i.e. each tooth entails a concentrated winding and two coil phases in each slot. In the case of single-layer winding, the reference tooth of two adjacent tooth coils is not wound. There is always only one phase of one coil found in the slots.
Insulated stator laminations at end plates
When using this type of stator design, lining the slot with insulation paper is not required. The plastic end plates are designed in a way that the sides of the injected shafts insulate half of the stator slot. It is also beneficial, that costs for paper as well as costs for the production process for the mounting of the paper do not arise.
Under consideration of a certain wall thickness of these injected shafts, z-shaped overlapping of the shafts in the area of the stator nut center may be achieved in order to increase the creepage distance and clearance to avoid dielectric breakdowns. However, a disadvantage constitutes in the fact that the depth of the shot of the injection process is limited depending on the stator lengths and the plastic material used.
When e.g. using PA with a solid material content (e.g. glass fibers) of approx. 25% and a shot of approx. 25 mm depth, a wall thickness of at least 0.5 mm may be achieved. However, it has negative repercussions on the fill factor compared to the use of insulation paper which e.g. is only 0.1 mm thick.
Molded stator laminations
An extended form of the stator's end insulation with injected slot shafts constitutes in the moulded stator. In the last few years, injection moulding has progressively been developed. It now allows to place the stator package into the injection mould and to facilitate the moulding process.
In doing so, the wall thickness reached is similar to that of the end plates with injected slot shafts. A particular benefit of this process lies in the fact that a pre-assembly of the end bells and the insulation paper can be avoided which prevents the danger of insulation gaps that could lead to short circuits.
However, due to the very costly complex injection mould, costs are only covered at a batch size of approx. 50.000 stators per year, compared to single component insulation. In addition, the diversity in types is only conditionally lucrative since a new injection mould needs to be produced whenever the length of the package or the laminations changes.
Definition of the fill factors for motor coils
Electric motors must be compact and lightweight. They should also deliver a higher output with less copper usage. A prerequisite for this is an appropriate design of the coil body and suitable wire dimensions.
One parameter of importance for the developer of motors is the electrical fill factor. The fill factor measures the ratio between the volume of a winding package and the volume needed to house the winding package.
In case of stators, it can be said that the electrical fill factor is the ratio of the content of non-ferrous metals of the stator including the stator slot to the sum of the uninsulated copper cross sections. But in contrast to round coils, only the stator slot is considered.
The reason for this is that merely the conductor strands in the stator slot contribute to the torque of the motor. The winding overhangs on the narrow sides of the winding cross section of a tooth only result in unwanted losses in the form of increasing electric resistance and undesired heat development.
Given: Wire-Ø Cu 0,5mm → CU1L=0,548mm (Value according to norm) 40 turns, insulated winding space = 35mm^2, insulation paper 0,25mm When looking at the insulated winding space graphically and the required number of windings at a given wire diameter, it can be said that considering the space requirements for the winding nozzle (required groove width: about 3*0.548=1.6 mm) only 38 windings can be introduced into the winding space of the stator slot. A= \frac{\pi \cdot D^2}{4} \cdot n \cdot 2 A= \frac{\pi \cdot 0.548^2}{4} \cdot 38 \cdot 2 = 17.9mm^2 A= Accumulated partial spaces of the insulated wires D L = wire gauge including the varnish coat n= Number of turns per tooth F_\text{mech}= A_\text{wire}/A_\text{winding space} \cdot 100\% F_\text{mech}= 17.9mm^2 / 35mm^2 \cdot 100\% F_\text{mech}= 51.1\% • Determination of the electrical fill factor The theoretical consideration takes place by assuming that the uninsulated wire is to be found in the uninsulated groove.
Given: Wire-Ø Cu 0,5mm 38 turns, non-insulated winding space = 41mm^2 A=\frac{\pi \cdot D^2}{4} \cdot n \cdot 2 A= Accumulated partial spaces of the non insulated wires D Cu = wire gauge excluding the varnish coat n= Number of turns per tooth A=\frac{\pi \cdot 0.5^2}{4} \cdot 38 \cdot 2 = 14.9mm^2 F_\text{electr}= A_\text{ wire }/A_\text{winding space} \cdot 100\% F_\text{electr}= 14.9mm^2 / 41 mm^2 \cdot 100\% F_\text{electr}= 36.3\%
External links
Toroid winding machine
Text derived from https://en.wikipedia.org/w/index.php?oldid=1367652139 under CC BY-SA 4.0; modifications have been made.