Common-path interferometer
A common-path interferometer is a class of interferometers in which the reference beam and sample beams travel along the same path. Examples include the Sagnac interferometer, Zernike phase-contrast interferometer, and the point diffraction interferometer. A common-path interferometer is generally more robust to environmental vibrations than a "double-path interferometer" such as the Michelson interferometer or the Mach–Zehnder interferometer. Although travelling along the same path, the reference and sample beams may travel along opposite directions, or they may travel along the same direction but with the same or different polarization. Double-path interferometers are highly sensitive to phase shifts or length changes between the reference and sample arms. Because of this, double-path interferometers have found wide use in science and industry for the measurement of small displacements, refractive-index changes, surface irregularities and the like. There are applications, however, in which sensitivity to relative displacement or refractive-index differences between reference and sample paths is not desirable; alternatively, one may be interested in the measurement of some other property.
Article summary
A common-path interferometer is a class of interferometers in which the reference beam and sample beams travel along the same path. Examples include the Sagnac interferometer, Zernike phase-contrast interferometer, and the point diffraction interferometer. A common-path interferometer is generally more robust to environmental vibrations than a "double-path interferometer" such as the Michelson interferometer or the Mach–Zehnder interferometer. Although travelling along the same path, the reference and sample beams may travel along opposite directions, or they may travel along the same direction but with the same or different polarization. Double-path interferometers are highly sensitive to phase shifts or length changes between the reference and sample arms. Because of this, double-path interferometers have found wide use in science and industry for the measurement of small displacements, refractive-index changes, surface irregularities and the like. There are applications, however, in which sensitivity to relative displacement or refractive-index differences between reference and sample paths is not desirable; alternatively, one may be interested in the measurement of some other property.
Key claims
- publication date: 1913 — source: Wikipedia, revision 1365792551, retrieved 2026-10-20 · confidence 0.95
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- The record states that the publication date is "1913". What evidence would count against this claim?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?