Compartmental neuron models

Compartmental modelling of dendrites deals with multi-compartment modelling of the dendrites, to make the understanding of the electrical behavior of complex dendrites easier.

Uses your system voice; voice and rate in settings.

Snapshot

≈ 8 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

Compartmental modelling of dendrites deals with multi-compartment modelling of the dendrites, to make the understanding of the electrical behavior of complex dendrites easier. Basically, compartmental modelling of dendrites is a very helpful tool to develop new biological neuron models.

Dendrites are very important because they occupy the most membrane area in many of the neurons and give the neuron an ability to connect to thousands of other cells. Originally the dendrites were thought to have constant conductance and current but now it has been understood that they may have active Voltage-gated ion channels, which influences the firing properties of the neuron and also the response of neuron to synaptic inputs.

Many mathematical models have been developed to understand the electric behavior of the dendrites. Dendrites tend to be very branchy and complex, so the compartmental approach to understand the electrical behavior of the dendrites makes it very useful.

Introduction

Compartmental models represent neurons as a series of connected compartments. Each compartment is described by differential equations that capture the flow of ionic currents and the resulting changes in membrane potential. This approach allows the complex geometry and electrical properties of real neurons to be approximated in a computationally tractable way.

General observations about how the brain functions can be made by looking at the first and second thermodynamic laws, which are universal laws. Brain is a very large-scale interconnected system; the neurons have to somehow behave like the chemical reaction system, so, it has to somehow obey the chemical thermodynamic laws.

This approach may lead to more generalized model of brain. i^i_\text{cap} + i^i_\text{ion} = i^i_\text{long} + i^i_\text{electrode} .....eq(1) where i^i_\text{cap} and i^i_\text{ion} are the capacitive and ionic currents per unit area of ith compartment membrane. i.e. they can be given by i^i_\text{cap} = c_i \frac{dV_i}{dt} and i^i_\text{ion} = \frac{V_i}{r_{Mi}} .....eq(2) If we assume the resting potential is 0. Then to compute i^i_\text{long} , we need total axial resistance.

As the compartments are simply cylinders we can say R_\text{long} = \frac{r_LL_1}{2 \pi a_1^2} + \frac{r_LL_2}{2 \pi a_2^2} .....eq(3) Using ohms law we can express current from ith to jth compartment as i^1_\text{long} = g_{1,2}(V_2-V_1) and i^2_\text{long} = g_{2,1}(V_1-V_2) .....eq(4) The coupling terms g_{1,2} and g_{2,1} are obtained by inverting eq(3) and dividing by surface area of interest. So we get g_{1,2} = \frac{a_1a_2^2}{r_LL_1(a_2^2L_1+a_1^2L_2)} and g_{2,1} = \frac{a_2a_1^2}{r_LL_1(a_1^2L_2+a_2^2L_1)} Finally, i_\text{electrode}^I = \frac {I_\text{electrode}^i}{A_i} A_i = 2 \pi a_iL_i is the surface area of the compartment i. If we put all these together we get c_1 \frac{dV_1}{dt} + \frac{V_1}{r_{M1}} = g_{1,2}(V_2 - V_1) + \frac {I_\text{electrode}^1}{A_1} c_2 \frac{dV_2}{dt} + \frac{V_2}{r_{M2}} = g_{2,1}(V_1 - V_2) + \frac {I_\text{electrode}^2}{A_2} .....eq(5) If we use r_1 = 1/g_{1,2} and r_2 = 1/g_{2,1} then eq(5) will become c_1 \frac{dV_1}{dt} + \frac{V_1}{r_{M1}} = \frac {V_2 - V_1}{r_1} + \frac {I_\text{electrode}^1}{A_1} c_2 \frac{dV_2}{dt} + \frac{V_2}{r_{M2}} = \frac {V_1 - V_2}{r_2} + \frac {I_\text{electrode}^2}{A_2} .....eq(6) Now if we inject current in cell 1 only and each cylinder is identical then r_1 = r_2 \equiv r Without loss in generality we can define r_M = r_{M1} = r_{M2} After some algebra we can show that \frac{V_1}{i_1} = \frac {r_M(r+r_M)}{r+2r_M} also \frac{R_\text{input,coupled}}{R_\text{input,uncoupled}} = 1- \frac{r_M}{r+2r_M} i.e. the input resistance decreases.

For increment in the potential, coupled system current should be greater than that is required for uncoupled system. This is because the second compartment drains some current. Now, we can get a general compartmental model for a treelike structure and the equations are C_j \frac{dV_j}{dt} = - \frac{V_j}{R_j} + \sum_{k \text{ connected } j}{} \frac{V_k - V_j}{R_{jk}}+I_j

Increased computational accuracy in multi-compartmental cable models

Input at the center Each dendritic section is subdivided into segments, which are typically seen as uniform circular cylinders or tapered circular cylinders. In the traditional compartmental model, point process location is determined only to an accuracy of half segment length. This will make the model solution particularly sensitive to segment boundaries.

The accuracy of the traditional approach for this reason is O(1/n) when a point current and synaptic input is present. Usually the trans-membrane current where the membrane potential is known is represented in the model at points, or nodes and is assumed to be at the center. The new approach partitions the effect of the input by distributing it to the boundaries of the segment.

Hence any input is partitioned between the nodes at the proximal and distal boundaries of the segment. Therefore, this procedure makes sure that the solution obtained is not sensitive to small changes in location of these boundaries because it affects how the input is partitioned between the nodes.

When these compartments are connected with continuous potentials and conservation of current at segment boundaries then a new compartmental model of a new mathematical form is obtained. This new approach also provides a model identical to the traditional model but an order more accurate.

This model increases the accuracy and precision by an order of magnitude than that is achieved by point process input.

Cable theory

Dendrites and axons are considered to be continuous (cable-like), rather than series of compartments.

Midbrain dopaminergic neuron

Movement, motivation, attention, neurological and psychiatric disorders and addictive behavior have a strong influence by Dopaminergic signalling. The dopaminergic neurons have a low irregular basal firing frequency in 1–8 Hz range in vivo in the ventral tegmental area (VTA) and substantia nigra pars compacta (SNc).

This frequencies can dramatically increase in response to a cue predicting reward or unpredicted reward. The actions that preceded the reward are reinforced by this burst or phasic signal. The low safety factor for action potential generation gives a result of low maximal steady frequencies.

The transient initial frequency in response to depolarizing pulse is controlled by rate of Ca 2+ accumulation in distal dendrites. Results obtained from a mulch-compartmental model realistic with reconstructed morphology were similar. So, the salient contributions of the dendritic architecture have been captures by simpler model.

Compartmental neural simulations with spatial adaptivity

The computational cost of the method scales not with the physical size of the system being simulated but with the amount of activity present in the simulation. Spatial adaptivity for certain problems reduces up to 80%.

Action potential (AP) initiation site

Establishing a unique site for AP initiation at the axon initial segment is no longer accepted. The APs can be initiated and conducted by different sub-regions of the neuron morphology, which widened the capabilities of individual neurons in computation.

Findings from a study of the Action Potential Initiation Site Along the Axosomatodendritic Axis of Neurons Using Compartmental Models: Dendritic APs are initiated more effectively by synchronous spatially clustered inputs than equivalent disperse inputs. The initiation site can also be determined by the average electrical distance from the dendritic input to the axon trigger zone, but it may be strongly modulated by the relative excitability of the two trigger zones and a number of factors.

A finite-state automaton model

Multi-neuron simulations with finite-state automaton model is capable of modelling the most important characteristics of neural membranes.

Multi-compartmental model of a CA1 pyramidal cell

To study changes in hippocampal excitability that result from aging-induced alterations in calcium-dependent membrane mechanisms, the multi-compartmental model of CA1 pyramidal cell can be used. We can model the aging-induced alterations in CA1 excitability can be with simple coupling mechanisms that selectively link specific types of calcium channels to specific calcium-dependent potassium channels.

Electrical compartmentalization

Spine Neck Plasticity Controls Postsynaptic Calcium Signals through Electrical Compartmentalization. The spine neck plasticity through a process of electrical compartmentalization can dynamically regulate Calcium influx into spines (a key trigger for synaptic plasticity).

Robust coding in motion-sensitive neurons

Different receptive fields in axons and dendrites underlie robust coding in motion-sensitive neurons.

Conductance-based neuron models

The capabilities and limitations of conductance-based compartmental neuron models with reduced branched or unbranched morphologies and active dendrites.

See also

Computational neuroscience Dynamical system Multi-compartment model Connectionism Neural network Biological neuron models Neural coding Brain-computer interface Neural engineering Neuroinformatics Mathematical model Compartmental models in epidemiology Physiologically-based pharmacokinetic modelling

Ted talk on supercomputing Laboratory of Biological Modelling Pharmacokinetics Modelling Tutorial Usefulness of two compartmental model in Pharmacokinetics Pharmacokinetics

Text derived from https://en.wikipedia.org/w/index.php?oldid=1372419888 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

15 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.