A computed tomography scan (CT scan), formerly known in a more rudimentary state as computed axial tomography scan (CAT scan), is a medical imaging technique used to obtain detailed internal images of the body. The personnel that perform CT scans are called radiographers or radiology technologists. CT scanners use a rotating X-ray tube and a row of detectors placed in a gantry to measure X-ray attenuations by different tissues inside the body. The multiple X-ray measurements taken from different angles are then processed on a computer using tomographic reconstruction algorithms to produce tomographic (cross-sectional) images (virtual "slices") of a body. CT scans can be used in patients with metallic implants or pacemakers, for whom magnetic resonance imaging (MRI) is contraindicated. Since its development in the 1970s, CT scanning has proven to be a versatile imaging technique. While CT is most prominently used in medical diagnosis, it can also be used to form images of non-living objects. The 1979 Nobel Prize in Physiology or Medicine was awarded jointly to British electrical engineer Godfrey Hounsfield and South African–American physicist Allan MacLeod Cormack "for the development of computer-assisted tomography".
A computed tomography scan (CT scan), formerly known in a more rudimentary state as computed axial tomography scan (CAT scan), is a medical imaging technique used to obtain detailed internal images of the body. The personnel that perform CT scans are called radiographers or radiology technologists. CT scanners use a rotating X-ray tube and a row of detectors placed in a gantry to measure X-ray attenuations by different tissues inside the body. The multiple X-ray measurements taken from different angles are then processed on a computer using tomographic reconstruction algorithms to produce tomographic (cross-sectional) images (virtual "slices") of a body. CT scans can be used in patients with metallic implants or pacemakers, for whom magnetic resonance imaging (MRI) is contraindicated. Since its development in the 1970s, CT scanning has proven to be a versatile imaging technique. While CT is most prominently used in medical diagnosis, it can also be used to form images of non-living objects. The 1979 Nobel Prize in Physiology or Medicine was awarded jointly to British electrical engineer Godfrey Hounsfield and South African–American physicist Allan MacLeod Cormack "for the development of computer-assisted tomography".
Sequential CT
Sequential CT, also known as step-and-shoot CT, is a type of scanning method in which the CT table moves stepwise. The table increments to a particular location and then stops, followed by rotation of the X-ray tube and acquisition of a slice. The table then increments again, and another slice is taken. The table movement stops while taking slices, which results in an increased scan duration.
Aviation security
CT scanning has also found an application in transport security (predominantly airport security), where it is currently used in a materials analysis context for explosives detection, CTX. It is also under consideration for automated baggage/parcel security scanning, using computer vision-based object-recognition algorithms that target the detection of specific threat items based on 3D appearance (e.g. guns, knives, liquid containers). Its usage in airport security, pioneered at Shannon Airport in March 2022, has ended the ban on liquids over 100 ml there, a move that Heathrow Airport planned for a full roll-out on 1 December 2022. The TSA spent $781.2 million on an order for over 1,000 scanners, ready to go live that summer.
Multiplanar reconstruction and projections
(upper right), sagittal (lower left), and coronal planes (lower right) . The smaller images are axial plane slices. Multiplanar reconstruction (MPR) is the process of converting data from one anatomical plane (usually transverse) to other planes. It can be used for thin slices as well as projections. Multiplanar reconstruction is possible as present CT scanners provide almost isotropic resolution. MPR is used almost in every scan. The spine is frequently examined with it. An image of the spine in axial plane can only show one vertebral bone at a time and cannot show its relation with other vertebral bones. By reformatting the data in other planes, visualization of the relative position can be achieved in sagittal and coronal plane. New software allows the reconstruction of data in non-orthogonal (oblique) planes, which help in the visualization of organs which are not in orthogonal planes. It is better suited for visualization of the anatomical structure of the bronchi as they do not lie orthogonal to the direction of the scan. Curved-plane reconstruction (or curved planar reformation = CPR) is performed mainly for the evaluation of vessels. This type of reconstruction helps to straighten the bends in a vessel, thereby helping to visualize a whole vessel in a single image or in multiple images. After a vessel has been "straightened", measurements such as cross-sectional area and length can be made. This is helpful in preoperative assessment of a surgical procedure. For 2D projections used in radiation therapy for quality assurance and planning of external beam radiotherapy, including digitally reconstructed radiographs, see beam's eye view.
Volume rendering
A threshold value of radiodensity is set by the operator (e.g., a level that corresponds to bone). With the help of edge detection image processing algorithms a 3D model can be constructed from the initial data and displayed on screen. Various thresholds can be used to get multiple models, each anatomical component such as muscle, bone and cartilage can be differentiated on the basis of different colours given to them. However, this mode of operation cannot show interior structures. Surface rendering is limited technique as it displays only the surfaces that meet a particular threshold density, and which are towards the viewer. However, In volume rendering, transparency, colours and shading are used which makes it easy to present a volume in a single image. For example, Pelvic bones could be displayed as semi-transparent, so that, even viewing at an oblique angle one part of the image does not hide another.