{
  "id": "enwiki-001298998675",
  "slug": "ct-value",
  "title": "CT Value",
  "qid": "",
  "lead": "CT Values are an important part of calculating disinfectant dosage for the chlorination of drinking water. A CT value is the product of the concentration of a disinfectant (e.g. free chlorine) and the contact time with the water being disinfected. It is typically expressed in units of mg-min/L. The goal of disinfection is the inactivation of microorganisms. This depends on: the microorganism, the disinfectant being used, the concentration of the disinfectant, the contact time, and the temperature and pH of the water.",
  "body": "CT Values are an important part of calculating disinfectant dosage for the chlorination of drinking water. A CT value is the product of the concentration of a disinfectant (e.g. free chlorine) and the contact time with the water being disinfected. It is typically expressed in units of mg-min/L. The goal of disinfection is the inactivation of microorganisms. This depends on: the microorganism, the disinfectant being used, the concentration of the disinfectant, the contact time, and the temperature and pH of the water. ==Kinetics== The disinfection kinetics are conventionally calculated via the Chick-Watson model, named for the work of Harriette Chick and H. E. Watson. This model is expressed by the following equation: \\ln(\\frac{N}{N_0})=-\\Lambda_{CW} C^n t \\! Where: (\\frac{N}{N_0}) \\! is the survival ratio for the microorganisms being killed \\Lambda_{CW} \\! is the Chick-Watson coefficient of specific lethality C \\! is the concentration of the disinfectant (typically in mg/L) n \\! is the coefficient of dilution, frequently assumed to be 1 t \\! is the contact time (typically in minutes or seconds) The survival ratio is commonly expressed as an inactivation ratio (in %) or as the number of reductions in the order of magnitude of the microorganism concentration. For example, a situation where N 0 =10 7 CFU/L and N=10 4 CFU/L would be reported as a 99.9% inactivation or \"3-log 10 \" removal. In water treatment practice, tables of the product C×t are used to calculate disinfection dosages. The calculated CT value is the product of the disinfectant residual (in mg/L) and the detention time (in minutes), through the section at peak hourly flow. These tables express the required CT values to achieve a desired removal of microorganisms of interest in drinking water (e.g. Giardia lamblia cysts) for a given disinfectant under constant temperature and pH conditions. A portion of such a table is reproduced below. ==Example CT Table== CT Values for the Inactivation of Giardia Cysts by Free Chlorine at 5&nbsp;°C and pH ≈ 7.0: Full tables are much larger than this example and should be obtained from the regulatory agency for a particular jurisdiction. ==See also== Chlorination Disinfectant ==References== ==External links==",
  "categories": [
    "20648693",
    "23018170"
  ],
  "license": "CC BY-SA 4.0",
  "source_uri": "https://en.wikipedia.org/w/index.php?oldid=1298998675",
  "content_hash": "",
  "created_at": null,
  "updated_at": 1751755307.0,
  "claims": [],
  "contradictions": [],
  "confidence": 0.6,
  "csl": {
    "id": "enwiki-001298998675",
    "type": "webpage",
    "title": "CT Value",
    "author": [
      {
        "family": "Anticloud FZ LLE",
        "literal": "Anticloud FZ LLE"
      }
    ],
    "container-title": "encyclopegia.org",
    "publisher": "Anticloud FZ LLE",
    "publisher-place": "Dubai, United Arab Emirates",
    "URL": "https://encyclopegia.org/a/ct-value",
    "issued": {
      "date-parts": [
        [
          2026,
          11,
          20
        ]
      ]
    },
    "accessed": {
      "date-parts": [
        [
          2026,
          11,
          20
        ]
      ]
    },
    "license": "CC BY-SA 4.0",
    "DOI": "eo1:enwiki-001298998675",
    "isBasedOn": "https://en.wikipedia.org/w/index.php?oldid=1298998675",
    "note": "Immutable snapshot enwiki-001298998675"
  }
}