Current sensing
≈ 9 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
In electrical engineering, current sensing is any one of several techniques used to measure electric current. The measurement of current ranges from picoamps to tens of thousands of amperes. The selection of a current sensing method depends on requirements such as magnitude, accuracy, bandwidth, robustness, cost, isolation or size. The current value may be directly displayed by an instrument, or converted to digital form for use by a monitoring or control system. Current sensing techniques include shunt resistor, current transformers and Rogowski coils, magnetic-field based transducers and others.
In electrical engineering, current sensing is any one of several techniques used to measure electric current. The measurement of current ranges from picoamps to tens of thousands of amperes. The selection of a current sensing method depends on requirements such as magnitude, accuracy, bandwidth, robustness, cost, isolation or size. The current value may be directly displayed by an instrument, or converted to digital form for use by a monitoring or control system. Current sensing techniques include shunt resistor, current transformers and Rogowski coils, magnetic-field based transducers and others.
Requirements in current measurement
Current sensing technologies must fulfill various requirements, for various applications. Generally, the common requirements are: High sensitivity High accuracy and linearity Wide bandwidth DC and AC measurement Low temperature drift Interference rejection IC packaging Low power consumption Low price
Techniques
The measurement of the electric current can be classified depending upon the underlying fundamental physical principles such as: Faraday's law of induction. Magnetic field sensors. Faraday effect. Transformer or current clamp meter (suitable for AC only). Fluxgate sensor (suitable for AC or DC). Hall-effect sensor (suitable for AC, DC, or pulsating current), a type of current sensor which is based on the Hall effect discovered by Edwin Hall in 1879. Shunt resistor, whose voltage is directly proportional to the current through it. Fiber-optic current sensor, using an interferometer to measure the phase change in the light produced by a magnetic field. Rogowski coil, electrical device for measuring alternating current (AC) or high-speed current pulses. Giant magnetoresistance (GMR): magnetic field sensor suitable for AC and DC with higher accuracy than Hall effect. Placed parallel to the magnetic field.
Shunt resistors
Ohm's law is the observation that the voltage drop across a resistor is proportional to the current going through it. This relationship can be used to sense currents. Sensors based on this simple relationship are well known for their lower costs, and reliability due to this simple principle. The common and simple approach to current sensing is the use of a shunt resistor. That the voltage drop across the shunt is proportional to its current flow, i.e. ohm's law, makes the low resistance current shunt a very popular choice for current measurement system with its low cost and high reliability. Both alternating currents (AC) and direct currents (DC) can be measured with the shunt resistor. The high performance coaxial shunt have been widely used for many applications fast rise-time transient currents and high amplitudes but, highly integrated electronic devices prefer low-cost surface mounted devices (SMDs), because of their small sizes and relatively low prices. The parasitic inductance present in the shunt affects high precision current measurement. Although this affects only the magnitude of the impedance at relatively high frequency, but also its effect on the phase at line frequency causes a noticeable error at a low power factor. The major disadvantage of using the shunt is that fundamentally a shunt is a resistive element, the power loss is thus proportional to the square of the current passing through it and consequently it is a rarity amongst high current measurements. Fast-response for measuring high-impulse or heavy-surge currents is the common requirement for shunt resistors. In 1981 Malewski, designed a circuit to eliminate the skin effect and later in 1999 the flat-strap sandwich shunt (FSSS) was introduced from a flat-strap sandwich resistor. The properties of the FSSS in terms of response time, power loss and frequency characteristics, are the same as the shunt resistor but the cost is lower and the construction technique is less sophisticated, compared to Malewski and the coaxial shunt. The intrinsic resistance of a conducting element, such as a copper trace on a printed circuit board can be used as a sensing resistor. This saves space and component cost. The voltage drop of a copper trace is very low due to its very low resistance, making the presence of a high gain amplifier mandatory in order to get a useful signal. Accuracy is limited by the initial tolerance of manufacturing the trace and the significant temperature coefficient of copper. A digital controller may apply corrections to improve the measurement. A significant drawback of a resistor sensor is the unavoidable electrical connection between the current to be measured and the measurement circuit. An isolation amplifier can provide electrical isolation between measured current and the rest of the measurement circuit. However, these amplifiers are expensive and can also limit the bandwidth, accuracy and thermal drift of the original current sensing technique. Other current sensing techniques that provide intrinsic electrical isolation may deliver a sufficient performance at lower costs where isolation is required.
Current sensor based on Faraday's law
Faraday's law of induction stating that the total electromotive force induced in a closed circuit is proportional to the time rate of change of the total magnetic flux linking the circuit has been largely employed in current-sensing techniques. Two major sensing devices based on Faraday’s law are current transformers (CTs) and Rogowski coils. These sensors provide an intrinsic electrical isolation between the current to be measured and the output signal, thus making these current-sensing devices mandatory where safety standards demand electrical isolation.
Current transformer
The CT is based on the principle of a transformer and converts a high primary current into a smaller secondary current and is common among high AC measurement system. As this device is a passive device, no extra driving circuitry is needed in its implementation. Another major advantage is that it can measure very high current while consuming little power. The disadvantage of the CT is that a very high primary current or a substantial DC component in the current can saturate the ferrite material used in the core, ultimately corrupting the signal. Another problem is that once the core is magnetized, it will contain hysteresis, and the accuracy will degrade unless it is demagnetized again.
Rogowski coil
Rogowski coil is based on Faraday’s law of induction and the output voltage V out of the Rogowski coil is determined by integrating the current I c to be measured. It is given by, V_\text{out} = -k \frac{NA\mu_0}{2\pi r} I_\text{c} + v_\text{out}(0), where A is the cross-sectional area of the coil, and N is the number of turns. The Rogowski coil has a low sensitivity due to the absence of a high-permeability magnetic core that the current transformer can take advantage of. However, this can be compensated for by adding more turns on the Rogowski coil or using an integrator with a higher gain k. More turns increase the self-capacitance and self-inductance, and higher integrator gain means an amplifier with a large gain–bandwidth product. As always in engineering, trade-offs must be made depending on specific applications.
Magnetic field sensors
Fluxgate sensors
Fluxgate sensors or saturable inductor current sensors work on the same measurement principle as Hall-effect-based current sensors: the magnetic field created by the primary current to be measured is detected by a specific sensing element. The design of the saturable inductor current sensor is similar to that of a closed-loop Hall-effect current sensor; the only difference is that this method uses the saturable inductor instead of the Hall-effect sensor in the air gap. Saturable inductor current sensor is based on the detection of an inductance change. The saturable inductor is made of small and thin magnetic core wound with a coil around it. The saturable inductor operates into its saturation region. It is designed in such a way that the external and internal flux density will affect its saturation level. Change in the saturation level of a saturable inductor will alter core’s permeability and, consequently, its inductance L. The value of saturable inductance (L) is high at low currents (based on the permeability of the core) and low at high currents (the core permeability becomes unity when saturated). When interpretating Fluxgate detectors, it needs to consider the property of many magnetic materials to exhibit a non-linear relationship between the magnetic field strength H and the flux density B. In this technique, high frequency performance is achieved by using two cores without air gaps. One of the two main cores is used to create a saturable inductor and the other is used to create a high frequency transformer effect. In another approach, three cores can be used without air gap. Two of the three cores are used to create saturable inductor, and the third core is used to create a high frequency transformer effect. Advantages of saturable inductor sensors include high resolution, high accuracy, low offset and gain drift, and large bandwidth (up to 500 kHz). Drawbacks of saturable inductor technologies include limited bandwidth for simpler design, relatively high secondary power consumption, and risk of current or voltage noise injection into the primary conductor. A widely used implementation of fluxgate technology for precision current measurement is the Direct Current Current Transformer (DCCT), also called zero-flux DCCT. This principle was first introduced at CERN in the 1960s and is today considered the state-of-the-art method for high-accuracy current sensing.
Text derived from https://en.wikipedia.org/w/index.php?oldid=1374586570 under CC BY-SA 4.0; modifications have been made.