Lesson plan
Dekatron
In electronics, a Dekatron (or Decatron, or generically three-phase gas counting tube or glow-transfer counting tube or cold cathode tube) is a gas-filled decade counting tube. Dekatrons were used in computers, calculators, and other counting-related products during the 1950s and 1960s. "Dekatron" was the brand name used by Ericsson Telephones Limited (ETL), of Beeston, Nottingham (not to be confused with the Swedish TelefonAB Ericsson of Stockholm) and has since become a generic trademark. The device was invented by John Reginald Acton, with the patent assigned to Ericsson. The dekatron was useful for computing, calculating, and frequency-dividing purposes because one complete revolution of the neon dot in a dekatron usually means 10 pulses on the guide electrode(s), and a signal can be derived from one of the cathodes in a dekatron to send a pulse, possibly for another counting stage. Dekatrons usually have a maximum input frequency in the high kilohertz (kHz) range – 100 kHz is fast, 1 MHz is around the maximum possible. These frequencies are obtained in hydrogen-filled fast dekatrons. Dekatrons filled with inert gas are inherently more stable and have a longer life, but their counting frequency is limited to 10 kHz (1–2 kHz is more common).
Article summary
In electronics, a Dekatron (or Decatron, or generically three-phase gas counting tube or glow-transfer counting tube or cold cathode tube) is a gas-filled decade counting tube. Dekatrons were used in computers, calculators, and other counting-related products during the 1950s and 1960s. "Dekatron" was the brand name used by Ericsson Telephones Limited (ETL), of Beeston, Nottingham (not to be confused with the Swedish TelefonAB Ericsson of Stockholm) and has since become a generic trademark. The device was invented by John Reginald Acton, with the patent assigned to Ericsson. The dekatron was useful for computing, calculating, and frequency-dividing purposes because one complete revolution of the neon dot in a dekatron usually means 10 pulses on the guide electrode(s), and a signal can be derived from one of the cathodes in a dekatron to send a pulse, possibly for another counting stage. Dekatrons usually have a maximum input frequency in the high kilohertz (kHz) range – 100 kHz is fast, 1 MHz is around the maximum possible. These frequencies are obtained in hydrogen-filled fast dekatrons. Dekatrons filled with inert gas are inherently more stable and have a longer life, but their counting frequency is limited to 10 kHz (1–2 kHz is more common).
Key claims
No claims recorded.
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?
Bibliography
No sources recorded.
Key claims and bibliography are generated from the same tracked claims and sources as the article page.