In telecommunications, electronics and the electrical power industry, the term demand factor is used to refer to the fractional amount of some quantity being used relative to the maximum amount that could be used by the same system.
≈ 4 min read
Demand factor. encyclopegia.org, snapshot enwiki-001244036648. /a/demand-factor
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
In telecommunications, electronics and the electrical power industry, the term demand factor is used to refer to the fractional amount of some quantity being used relative to the maximum amount that could be used by the same system. The demand factor is always less than or equal to one. As the amount of demand is a time dependent quantity so is the demand factor.
- fDemand(t)=DemandMaximum possible demand
The demand factor is often implicitly averaged over time when the time period of demand is understood by the context.
Electrical engineering
edit edit sourceIn electrical engineering the demand factor is taken as a time independent quantity where the numerator is taken as the maximum demand in the specified time period instead of the averaged or instantaneous demand.
- fDemand=Maximum load in given time periodMaximum possible load
This is the peak in the load profile divided by the full load of the device.
Example: If a residence has equipment which could draw 6,000 W when all equipment was drawing a full load, drew a maximum of 3,000 W in a specified time, then the demand factor = 3,000 W / 6,000 W = 0.5
This quantity is relevant when trying to establish the amount of load for which a system should be rated. In the above example, it would be unlikely that the system would be rated to 6,000 W, even though there may be a slight possibility that this amount of power can be drawn. This is closely related to the load factor which is the average load divided by the peak load in a specified time period.
- fLoad=Average loadMaximum load in given time period
See also
edit edit sourceReferences
edit edit source- This article incorporates public domain material from Federal Standard 1037C. General Services Administration. Archived from the original on 2022-01-22. (in support of MIL-STD-188).
- Automatic generation control
- Backfeeding
- Base load
- Demand factor
- Droop speed control
- Electric power
- Electric power quality
- Electrical fault
- Energy demand management
- Energy return on investment
- Grid code
- Grid strength
- Home energy storage
- Load-following
- Merit order
- Nameplate capacity
- Peak demand
- Power factor
- Power-flow study
- Power system reliability
- Repowering
- Utility frequency
- Variability
- Fossil fuel power station
- Nuclear
and distribution
- Ancillary services
- Balancing authority
- Contingency (electrical grid)
- Demand response
- Distributed generation
- Dynamic demand
- Electric power distribution
- Electric power system
- Electric power transmission
- Electrical busbar system
- Electrical grid
- Electricity retailing
- Grid balancing
- High-voltage direct current
- High-voltage shore connection
- Interconnector
- Load management
- Mains electricity by country
- Overhead power line
- Power station
- Pumped hydro
- Single-wire earth return
- Smart grid
- Substation
- Super grid
- Transformer
- Transmission system operator (TSO)
- Transmission tower
- Utility pole
- Voltage control and reactive power management
devices
and policies
- Availability factor
- Capacity factor
- Carbon offsets and credits
- Cost of electricity by source
- Energy subsidies
- Environmental tax
- Feed-in tariff
- Fossil fuel phase-out
- Load factor
- Net metering
- Pigouvian tax
- Renewable Energy Certificates
- Renewable energy commercialization
- Renewable Energy Payments
- Spark/Dark/Quark/Bark spread
production
Text derived from https://en.wikipedia.org/w/index.php?oldid=1244036648 under CC BY-SA 4.0; modifications have been made.