Du Noüy ring method
In surface science, the du Noüy ring method is a technique for measuring the surface tension of a liquid.
≈ 2 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
In surface science, the du Noüy ring method is a technique for measuring the surface tension of a liquid. This technique was proposed by Pierre Lecomte du Noüy in 1925.
The measurement is performed with a force tensiometer, which typically uses an electrobalance to measure the excess force caused by the liquid being pulled up and automatically calculates and displays the surface tension corresponding to the force. Earlier, torsion wire balances were commonly used.
F = w_\text{ring} + 2\pi \cdot (r_\text{i} + r_\text{a}) \cdot \gamma, where is the radius of the inner ring of the liquid film pulled, and is the radius of the outer ring of the liquid film. is the weight of the ring minus the buoyant force due to the part of the ring below the liquid surface. When the ring's thickness is much smaller than its diameter, this equation can be simplified to F = w_\text{ring} + 4\pi R \gamma, where is the average of the inner and outer radius of the ring, i.e. (r_\text{i} + r_\text{a})/2.
The maximum force is used for the calculations, and empirically determined correction factors are required to remove the effect caused by the finite diameter of the ring: F = w_\text{ring} + 4\pi R \gamma f, with being the correction factor. \gamma = \frac{F}{4 \pi R} f, where is surface tension, is the average radius of the ring, and is correction factor.
Zuidema–Waters correction factors
H. H. Zuidema and George W. Waters introduced the following correction factor in 1961: (f - a)^2 = \frac{4b}{\pi ^2} \frac{1}{R^2} \frac{\gamma_\text{measured}}{\rho_\text{lower} - \rho_\text{upper}} + C, where = maximum pull of rings [ dyn/cm], = density of the lower and upper phases, C = 0.04534 - 1.679 \frac{r}{R}, , [s 2 ⋅cm −1 ], = Du Noüy wire radius, = Du Noüy ring radius.
Huh–Mason correction factors
C. Huh and S. G. Mason described the correction factors as a function of \tfrac{R}{r} and \tfrac{R^3}{V}. See the references.
Harkins–Jordan correction factors
William Draper Harkins and Hubert F. Jordan tabulated the correction factors as a function of R/r and R^3/V . Video showing a classical torsion wire du Noüy tensiometer Picture of a classical torsion wire du Noüy tensiometer (National Institutes of Health)
Text derived from https://en.wikipedia.org/w/index.php?oldid=1302150092 under CC BY-SA 4.0; modifications have been made.