In analytical chemistry, the Dumas method is a method of elemental analysis for the quantitative determination of nitrogen in chemical substances based on a method first described by Jean-Baptiste Dumas in 1826. The Dumas technique has been automated and instrumentalized, so that it is capable of rapidly measuring the crude protein concentration of food samples. This automatic Dumas technique has replaced the Kjeldahl method as the standard method of analysis for nutritional labelling of protein content of foods (except in high fat content foods where the Kjeldahl method is still preferred due to fire risks).
In analytical chemistry, the Dumas method is a method of elemental analysis for the quantitative determination of nitrogen in chemical substances based on a method first described by Jean-Baptiste Dumas in 1826. The Dumas technique has been automated and instrumentalized, so that it is capable of rapidly measuring the crude protein concentration of food samples. This automatic Dumas technique has replaced the Kjeldahl method as the standard method of analysis for nutritional labelling of protein content of foods (except in high fat content foods where the Kjeldahl method is still preferred due to fire risks). Under the operating conditions of the Dumas method, the mass fraction of nitrogen should remain small enough, such that the relation is approximately linear. That is, we have k = k_{He} + \alpha m\% for some proportionality constant \alpha , when m\% is small. The signal measured by the detector begins with a plateau, indicating k_{He} . Then it shows a major spike indicating a nitrogen–helium mixture k = k_{He} + \alpha m\% . There may be two minor spikes, well-separated from the major spike, indicating the trace presence of carbon dioxide and water. Now, suppose the major spike is contained in an interval [t_1, t_2] , then take a time-integral, m_{N_2} = \alpha^{-1} \int_{t_1}^{t_2} (k(t) - k_{He}) \dot m(t) dt where \dot m is the mass rate of gas flow through the detector. As \alpha is unknown, ihe instrument must first be calibrated by analyzing a pure sample containing a known mass of nitrogen. This allows us to measure \alpha . After the nitrogen content is measured, one can convert this to the crude protein content, using conversion factors which depend on the particular amino acid sequence of the measured protein. This is the same as with the Kjeldahl method.
See also
Combustion analysis, a similar approach to Dumas but involving carbon, hydrogen, and nitrogen as well Bicinchoninic acid assay, a colorimetric analysis method for protein-nitrogen
References
Text derived from https://en.wikipedia.org/w/index.php?oldid=1358170673 under CC BY-SA 4.0; modifications have been made.