Duplex sequencing

Uses your system voice; voice and rate in settings.

Snapshot

≈ 7 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

Duplex sequencing is a library preparation and analysis method for next-generation sequencing (NGS) platforms that employs random tagging of double-stranded DNA to detect mutations with higher accuracy and lower error rates. This method uses degenerate molecular tags in addition to sequencing adapters to recognize reads originating from each strand of DNA. As the two strands are complementary, true mutations are found at the same position in both strands. In contrast, PCR or sequencing errors result in mutations in only one strand and can thus be discounted as technical error. Duplex sequencing theoretically can detect mutations with frequencies as low as 5 × 10 −8 --that is more than 10,000 times higher in accuracy compared to the conventional next-generation sequencing methods. The estimated error rate of standard next-generation sequencing platforms is 10 −2 to 10 −3 per base call. With this error rate, billions of base calls that are produced by NGS will result in millions of errors. The errors are introduced during sample preparation and sequencing such as polymerase chain reaction, sequencing, and image analysis errors.…

Duplex sequencing is a library preparation and analysis method for next-generation sequencing (NGS) platforms that employs random tagging of double-stranded DNA to detect mutations with higher accuracy and lower error rates. This method uses degenerate molecular tags in addition to sequencing adapters to recognize reads originating from each strand of DNA. As the two strands are complementary, true mutations are found at the same position in both strands. In contrast, PCR or sequencing errors result in mutations in only one strand and can thus be discounted as technical error. Duplex sequencing theoretically can detect mutations with frequencies as low as 5 × 10 −8 --that is more than 10,000 times higher in accuracy compared to the conventional next-generation sequencing methods. The estimated error rate of standard next-generation sequencing platforms is 10 −2 to 10 −3 per base call. With this error rate, billions of base calls that are produced by NGS will result in millions of errors. The errors are introduced during sample preparation and sequencing such as polymerase chain reaction, sequencing, and image analysis errors. While the NGS platforms' error rate is acceptable in some applications such as detection of clonal variants, it is a major limitation for applications that require higher accuracy for detection of low-frequency variants such as detection of intra-organismal mosaicism, subclonal variants in genetically heterogeneous cancers, or circulating tumor DNA. Several library preparation strategies have been developed that increase accuracy of NGS platforms such as molecular barcoding and circular consensus sequencing method. Like NGS platforms, the data generated by these methods originates from a single strand of DNA, and therefore the errors that are introduced during PCR amplification, tissue processing, DNA extraction, hybridization capture (where used) or DNA sequencing itself can still be distinguished as a true variant. The duplex sequencing method addresses this problem by taking advantage of the complementary nature of two strands of DNA and confirming only variants that are present in both strands of DNA. Because the probability of two complementary errors arising at the same location in both strands is exceedingly low, duplex sequencing increases the accuracy of sequencing significantly.

Experimental workflow

Duplex sequencing tagged adapters can be used in combination with the majority of NGS adapters. In the figures and workflow section of this article, Illumina sequencing adapters are used as an example following the original published protocol.

Insertion of sequencing adapters to tagged libraries

In the last step of duplex sequencing library preparation, Illumina sequencing adapters are added to the tagged double stranded libraries by PCR amplification using primers containing sequencing adapters. During PCR amplification, both complementary strands of DNA are amplified and generate two types of PCR products. Product 1 derives from strand 1's which have a unique tag sequence (called α in Figure 2) next to the Illumina adapter 1 and product 2 has a unique tag (called β in Figure 2) next to the Illumina adapter 1. (In each strand, tag α is the reverse complement of tag β and vice versa). The libraries containing duplex tags and Illumina adapters are sequenced using the Illumina TruSeq system. Reads that are originating from every single strand of DNA form a group of reads (tag families) that share the same tag. The detected families of reads will be used in the next step for analyzing sequencing data.

Efficiency of adapter ligation

Adapter ligation efficiency is very important in successful duplex sequencing. An extra amount of libraries or adapters can affect the DNA to adapter balance, resulting in inefficient ligation and an excess amount of primer dimers, respectively. Therefore, it is important to keep the molar concentration of DNA to adapter at the optimal ratio (0.05).

Tag family size

The efficiency of duplex sequencing depends on the final number of DCSs which is directly related to the number of reads in each family (family size). If the family size is too small then the DCS can not be assembled and if too many reads are sharing the same tag, the data yield will be low. Family size is determined by the amount of DNA template needed for PCR amplification and the dedicated sequencing lane fraction. The optimal tag family size is between 6 and 12 members1. To obtain the optimal family size, the amounts of DNA template and the dedicated sequencing lane fraction need to be adjusted. The following formula takes into account the most important variables that can affect depth of coverage (N=40DG÷R) where "N" is the number of reads, "D" is the desired depth of coverage, "G" is the size of DNA target in base pair, and "R" is final read length.

SSCS assembly

Trimmed sequences from the previous step are aligned to the reference genome using a Burrows–Wheeler aligner (BWA) and the unmapped reads are removed. The aligned reads that have the same 24-base pair tag sequence and genomic region are detected and grouped (family αβ and βα in Figure 2). Each group represents a “tag family.” Tag families with fewer than three members are not analyzed. To remove errors that arise during PCR amplification or sequencing, mutations that are supported by less than 70% of the members (reads) are filtered out from the analysis. A consensus sequence is then generated for each family using the identical sequences in each position of the remaining reads. The consensus sequence is called the SSCS. It increases the NGS accuracy to about 20 fold higher; however, this method relies on the sequencing information from single strands of DNA and therefore is sensitive to the errors induced at the first round or before PCR amplification.

Limitations

Applications

Detection of variants with low frequencies

Duplex sequencing and the significant increase of sequencing accuracy has had an important impact on applications such as detection of rare human genetic variants, detection of subclonal mutations involved in mechanisms of resistance to therapy in genetically heterogeneous cancers, screening variants in circulating tumor DNA as a non-invasive biomarker, and prenatal screening for genetic abnormalities in a fetus.

Copy number detection

Another application for duplex sequencing is in the detection of DNA/RNA copy numbers by estimating the relative frequency of variants. A method for counting PCR template molecules with application to next-generation sequencing is an example.

Analysis and software

A list of required tools and packages for SSCS and DCS analysis can be found online.

References

Text derived from https://en.wikipedia.org/w/index.php?oldid=1369866345 under CC BY-SA 4.0; modifications have been made.

References

  1. ↩Wikipedia members (×1) · confidence 0.95 https://en.wikipedia.org/w/index.php?oldid=1369866345