Lesson plan

Electrical isolation test

In electrical engineering, an electrical isolation test is a direct current (DC) or alternating current (AC) resistance test that is performed on sub-systems of an electronic system to verify that a specified level of isolation resistance is met. Isolation testing may also be conducted between one or more electrical circuits of the same subsystem. The test often reveals problems that occurred during assembly, such as defective components, improper component placement, and insulator defects that may cause inadvertent shorting or grounding to chassis, in turn, compromising electrical circuit quality and product safety. Isolation resistance measurements may be achieved using a high input impedance ohmmeter, digital multimeter (DMM) or current-limited Hipot test instrument. The selected equipment should not over-stress sensitive electronic components comprising the subsystem. The test limits should also consider semiconductor components within the subsystem that may be activated by the potentials imposed by each type of test instrumentation. A minimum acceptable resistance value is usually specified (typically in the mega ohm (MΩ) range per circuit tested). Multiple circuits having a common return may be tested simultaneously, provided the minimum allowable resistance value is based on the number of circuits in parallel.…

Back to article

Article summary

In electrical engineering, an electrical isolation test is a direct current (DC) or alternating current (AC) resistance test that is performed on sub-systems of an electronic system to verify that a specified level of isolation resistance is met. Isolation testing may also be conducted between one or more electrical circuits of the same subsystem. The test often reveals problems that occurred during assembly, such as defective components, improper component placement, and insulator defects that may cause inadvertent shorting or grounding to chassis, in turn, compromising electrical circuit quality and product safety. Isolation resistance measurements may be achieved using a high input impedance ohmmeter, digital multimeter (DMM) or current-limited Hipot test instrument. The selected equipment should not over-stress sensitive electronic components comprising the subsystem. The test limits should also consider semiconductor components within the subsystem that may be activated by the potentials imposed by each type of test instrumentation. A minimum acceptable resistance value is usually specified (typically in the mega ohm (MΩ) range per circuit tested). Multiple circuits having a common return may be tested simultaneously, provided the minimum allowable resistance value is based on the number of circuits in parallel.…

Key claims

No claims recorded.

Discussion questions

  1. Summarise the article in your own words. Which single claim would you verify first, and why?
  2. Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
  3. If two sources disagreed about one of these facts, what would you need in order to trust one over the other?

Bibliography

No sources recorded.

Key claims and bibliography are generated from the same tracked claims and sources as the article page.