Electrodermal activity

Uses your system voice; voice and rate in settings.

Snapshot

≈ 7 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

Electrodermal activity (EDA) is the property of the human body that causes continuous variation in the electrical characteristics of the skin. Historically, EDA has also been known as skin conductance, galvanic skin response (GSR), electrodermal response (EDR), psychogalvanic reflex (PGR), skin conductance response (SCR), sympathetic skin response (SSR) and skin conductance level (SCL).

The long history of research into the active and passive electrical properties of the skin by a variety of disciplines has resulted in an excess of names, now standardized to electrodermal activity (EDA). The traditional theory of EDA holds that skin resistance varies with the state of sweat glands in the skin. Sweating is controlled by the sympathetic nervous system, and skin conductance is an indication of psychological or physiological arousal.

If the sympathetic branch of the autonomic nervous system is highly aroused, then sweat glands activity also increases, which in turn increases skin conductivity. In this way, skin conductivity can be a measure of emotional and sympathetic responses. But the theory associating sweat and EDA was already debated decades ago since individuals without sweat glands have an EDA signal : ""The source of the skin potential is presumed to be the sweat glands and the epidermis, although it is present in subjects with congenital absence of sweat glands ...…

Electrodermal activity (EDA) is the property of the human body that causes continuous variation in the electrical characteristics of the skin. Historically, EDA has also been known as skin conductance, galvanic skin response (GSR), electrodermal response (EDR), psychogalvanic reflex (PGR), skin conductance response (SCR), sympathetic skin response (SSR) and skin conductance level (SCL).

The long history of research into the active and passive electrical properties of the skin by a variety of disciplines has resulted in an excess of names, now standardized to electrodermal activity (EDA). The traditional theory of EDA holds that skin resistance varies with the state of sweat glands in the skin. Sweating is controlled by the sympathetic nervous system, and skin conductance is an indication of psychological or physiological arousal.

If the sympathetic branch of the autonomic nervous system is highly aroused, then sweat glands activity also increases, which in turn increases skin conductivity. In this way, skin conductivity can be a measure of emotional and sympathetic responses.

But the theory associating sweat and EDA was already debated decades ago since individuals without sweat glands have an EDA signal : ""The source of the skin potential is presumed to be the sweat glands and the epidermis, although it is present in subjects with congenital absence of sweat glands ... this is not a test of “sweat” function, it is often included in this category as a measure of sudomotor activity". ".

This debate is ongoing since more recent technology (see Electrochemical skin conductance) demonstrated a real measure of sweat conductivity with several medical applications. A good way to differentiate both is to look at measures values and type : EDA is a continuous measurement (signal curve with time) given in μS (microsiemens) with value mostly 2 ). The response of the skin and muscle tissue to external and internal stimuli can cause the conductance to vary by several microsiemens.

A correctly calibrated device can record and display the subtle changes. The combined changes between electrodermal resistance and electrodermal potential make up electrodermal activity. Galvanic skin resistance (GSR) is an older term that refers to the recorded electrical resistance between two electrodes when a very weak current is steadily passed between them. The electrodes are normally placed about an inch apart, and the resistance recorded varies according to the emotional state of the subject.

Galvanic skin potential (GSP) refers to the voltage measured between two electrodes without any externally applied current. It is measured by connecting the electrodes to a voltage amplifier. This voltage also varies with the emotional state of the subject.

Examples

A painful stimulus such as a pinprick elicits a sympathetic response by the sweat glands, increasing secretion. Although this increase is generally very small, sweat contains water and electrolytes, which increase electrical conductivity, thus lowering the electrical resistance of the skin. These changes in turn affect GSR. Another common manifestation is the vasodilation (dilation) of blood vessels in the face, referred to as blushing, as well as increased sweating that occurs when one is embarrassed. EDA is highly responsive to emotions in some people.

Fear, anger, startled response, orienting response, and sexual feelings are among the reactions that may be reflected in EDA. These responses are utilized as part of the polygraph or lie detector test. EDA in regular subjects differs according to feelings of being treated fairly or unfairly, but psychopaths have been shown to manifest no such differences. This indicates that the EDA record of a polygraph may be deceptive in a criminal investigation.

Uses

EDA is a common measure of autonomic nervous system activity, with a long history of being used in psychological research. Hugo D. Critchley, Chair of Psychiatry at the Brighton and Sussex Medical School states, "EDA is a sensitive psychophysiological index of changes in autonomic sympathetic arousal that are integrated with emotional and cognitive states." Many biofeedback therapy devices utilize EDA as an indicator of the user's stress response with the goal of helping the user to control anxiety.

EDA is used to assess an individual's neurological status without using traditional, but uncomfortable and expensive, EEG-based monitoring. It has also been used as a proxy of psychological stress. EDA has also been studied as a method of pain assessment in premature born infants. Often, EDA monitoring is combined with the recording of heart rate, respiratory rate, and blood pressure, because they are all autonomically dependent variables. EDA measurement is one component of modern polygraph devices, which are often used as lie detectors.

Possible problems

External factors such as temperature and humidity affect EDA measurements, which can lead to inconsistent results. Internal factors such as medications and hydration can also change EDA measurements, demonstrating inconsistency with the same stimulus level.

Also, the classic understanding has treated EDA as if it represented one homogeneous change in arousal across the body, but in fact different locations of its measurement can lead to different responses; for example, the responses on the left and right wrists are driven by different regions of the brain, providing multiple sources of arousal; thus, the EDA measured in different places on the body varies not only with different sweat gland density but also with different underlying sources of arousal.

Lastly, electrodermal responses are delayed 1–3 seconds. These show the complexity of determining the relationship between EDA and sympathetic activity. The skill of the operator may be a significant factor in the successful application of the tool.

See also

Affective computing Biosignal Electroacupuncture E-meter

Notes

References

Carlson, Neil (2013). Physiology of Behavior. New Jersey: Pearson Education, Inc. . Figner, B., & Murphy, R. O. (2010). Using skin conductance in judgment and decision making research. A Handbook of Process Tracing Methods for Decision Research: A Critical Review and User's Guide, 163–84. Pflanzer, Richard. "Galvanic Skin Response and the Polygraph". BIOPAC Systems, Inc. Retrieved 5 May 2013.

Text derived from https://en.wikipedia.org/w/index.php?oldid=1365645650 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

15 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.