An electromagnet is a type of magnet in which the magnetic field is produced by an electric current. Electromagnets usually consist of copper wire wound into a coil. A current through the wire creates a magnetic field which is concentrated along the center of the coil. The magnetic field disappears when the current is turned off. The wire turns are often wound around a magnetic core made from a ferromagnetic or ferrimagnetic material such as iron; the magnetic core concentrates the magnetic flux and makes a more powerful magnet.

The main advantage of an electromagnet over a permanent magnet is that the magnetic field can be quickly changed by controlling the amount of electric current in the winding. However, unlike a permanent magnet, which needs no power, an electromagnet requires a continuous supply of current to maintain the magnetic field. Electromagnets are widely used as components of other electrical devices, such as motors, generators, electromechanical solenoids, relays, loudspeakers, hard disks, MRI machines, scientific instruments, and magnetic separation equipment.

Electromagnets are also employed in industry for picking up and moving heavy iron objects such as scrap iron and steel.

An electromagnet is a type of magnet in which the magnetic field is produced by an electric current. Electromagnets usually consist of copper wire wound into a coil. A current through the wire creates a magnetic field which is concentrated along the center of the coil. The magnetic field disappears when the current is turned off. The wire turns are often wound around a magnetic core made from a ferromagnetic or ferrimagnetic material such as iron; the magnetic core concentrates the magnetic flux and makes a more powerful magnet.

The main advantage of an electromagnet over a permanent magnet is that the magnetic field can be quickly changed by controlling the amount of electric current in the winding. However, unlike a permanent magnet, which needs no power, an electromagnet requires a continuous supply of current to maintain the magnetic field. Electromagnets are widely used as components of other electrical devices, such as motors, generators, electromechanical solenoids, relays, loudspeakers, hard disks, MRI machines, scientific instruments, and magnetic separation equipment.

Electromagnets are also employed in industry for picking up and moving heavy iron objects such as scrap iron and steel.

Simple solenoid

(coil of wire). This drawing shows a cross-section through the center of the coil. The crosses are wires in which current is moving into the page; the dots are wires in which current is moving up out of the page. A common tractive electromagnet is a uniformly wound solenoid and plunger. The solenoid is a coil of wire, and the plunger is made of a material such as soft iron. Applying a current to the solenoid applies a force to the plunger and may make it move. The plunger stops moving when the forces upon it are balanced.

For example, the forces are balanced when the plunger is centered in the solenoid. The maximum uniform pull happens when one end of the plunger is at the middle of the solenoid. An approximation for the force is where is a proportionality constant, is the cross-sectional area of the plunger, is the number of turns in the solenoid, is the current through the solenoid wire, and is the length of the solenoid.

For long, slender, solenoids (in units using inches, pounds force, and amperes), the value of is around 0.009 to 0.010 psi (maximum pull pounds per square inch of plunger cross-sectional area). For example, a 12-inch-long coil ( ) with a long plunger with a cross section of one inch square ( ) and 11,200 ampere-turns ( ) had a maximum pull of 8.75 pounds (corresponding to ). The maximum pull is increased when a magnetic stop is inserted into the solenoid.

The stop becomes a magnet that will attract the plunger; it adds little to the solenoid pull when the plunger is far away but dramatically increases the pull when the plunger is close. An approximation for the pull is P = A N I \left[\frac{N I}{(\ell_\mathrm{a})^2 (C_1)^2} + \frac C \ell\right] = \frac{A N^2 I^2}{(\ell_\mathrm{a})^2 (C_1)^2} + \frac{C A N I}{\ell} Here is the distance between the end of the stop and the end of the plunger. The additional constant for units of inches, pounds, and amperes with slender solenoids is about 2660 .

The first term inside the bracket represents the attraction between the stop and the plunger; the second term represents the same force as the solenoid without a stop ( ). Some improvements can be made on this basic design. The ends of the stop and plunger are often conical. For example, the plunger may have a pointed end that fits into a matching recess in the stop. The shape makes the solenoid's pull more uniform as a function of separation.

Another improvement is to add a magnetic return path around the outside of the solenoid (an "iron-clad solenoid"). The magnetic return path, just as the stop, has little impact until the air gap is small.

Ampere's law

The magnetic field of electromagnets in the general case is given by Ampere's law: \int \mathbf{J}\cdot d\mathbf{A} = \oint \mathbf{H}\cdot d\boldsymbol{\ell} which says that the integral of the magnetizing field \mathbf{H} around any closed loop is equal to the sum of the current flowing through the loop.

A related equation is the Biot–Savart law, which gives the magnetic field due to each small segment of current. \frac{F}{A} = \frac {(B_\text{sat})^2}{2 \mu_0} \approx 1000\ \mathrm{kPa} = 10^6 \mathrm{N/m^2} = 145\ \mathrm for the core's saturation limit, B_{sat} . In more intuitive units, it is useful to remember that at 1 T the magnetic pressure is approximately . Given a core geometry, the magnetic field needed for a given force can be calculated from ( ); if the result is much more than 1.6 T, a larger core must be used.

However, computing the magnetic field and force exerted by ferromagnetic materials in general is difficult for two reasons. First, the strength of the field varies from point to point in a complicated way, particularly outside the core and in air gaps, where fringing fields and leakage flux must be considered. Second, the magnetic field and force are nonlinear functions of the current, depending on the nonlinear relation between B and \mathbf{H} for the particular core material used.

For precise calculations, computer programs that can produce a model of the magnetic field using the finite element method are employed. NI = H_{\mathrm{core}} L_{\mathrm{core}} + H_{\mathrm{gap}} L_{\mathrm{gap}} {{NumBlk|:| NI = B \left(\frac{L_{\mathrm{core}}}{\mu} + \frac{L_{\mathrm{gap}}}{\mu_0} \right) | }} This is a nonlinear equation, because the permeability of the core \mu varies with B . For an exact solution, \mu(B) must be obtained from the core material hysteresis curve. If B is unknown, the equation must be solved by numerical methods.

However, if the magnetomotive force is well above saturation (so the core material is in saturation), the magnetic field will be approximately the material's saturation value B_{sat} , and will not vary much with changes in NI . For a closed magnetic circuit (no air gap), most core materials saturate at a magnetomotive force of roughly 800 ampere-turns per meter of flux path. For most core materials, the relative permeability \mu_r \approx 2000 \text{–} 6000\, . So in ( ), the second term dominates.

Therefore, in magnetic circuits with an air gap, B depends strongly on the length of the air gap, and the length of the flux path in the core does not matter much. Given an air gap of 1mm, a magnetomotive force of about 796 ampere-turns is required to produce a magnetic field of 1 T. m = \frac{NIA}{L} and thus the force between two poles is F = \frac{\mu_0 m_1 m_2}{4\pi r^2}. Each electromagnet has two poles, so the total force on magnet 1 from magnet 2 is equal to the vector sum of the forces of magnet 2's poles acting on each pole of magnet 1.

Side effects

There are several side effects which occur in electromagnets, which must be considered in their design. These effects generally become more significant in larger electromagnets.

Ohmic heating

(Laboratoire National des Champs Magnétiques Intenses) high field laboratory The only power consumed in a direct current (DC) electromagnet under steady-state conditions is due to the resistance of the windings, and is dissipated as heat. Some large electromagnets require water cooling systems in the windings to carry off the waste heat. Since the magnetic field is proportional to the product NI , the number of turns in the windings N and the current I can be chosen to minimize heat losses, as long as their product is constant.

Since the power dissipation, P=I^2R , increases with the square of the current but only increases approximately linearly with the number of windings, the power lost in the windings can be minimized by reducing I and proportionally increasing the number of turns N , or using thicker wire to reduce the resistance. For example, halving I and doubling N halves the power loss, as does doubling the area of the wire. In either case, increasing the amount of wire reduces the ohmic losses.

For this reason, electromagnet windings often have a significant thickness. However, the limit to increasing N or lowering the resistance is that the windings take up more space between the magnet's core pieces. If the area available for windings is filled up, adding more turns requires a smaller diameter of wire, which has higher resistance, and thus cancels the advantage of using more turns. So, in large magnets there is a minimum amount of heat loss that cannot be reduced. This increases with the square of the magnetic flux, B^2 .

Inductive voltage spikes

An electromagnet has significant inductance, and resists changes in the current through its windings. Any sudden changes in the winding current cause large voltage spikes across the windings. This is because when the current through the magnet is increased, such as when it is turned on, energy from the circuit must be stored in the magnetic field. When it is turned off, the energy in the field is returned to the circuit. If an ordinary switch is used to control the winding current, this can cause sparks at the terminals of the switch.

This does not occur when the magnet is switched on, because the limited supply voltage causes the current through the magnet and the field energy to increase slowly. But when it is switched off, the energy in the magnetic field is suddenly returned to the circuit, causing a large voltage spike and an arc across the switch contacts, which can damage them. With small electromagnets, a capacitor is sometimes used across the contacts, which reduces arcing by temporarily storing the current.

More often, a diode is used to prevent voltage spikes by providing a path for the current to recirculate through the winding until the energy is dissipated as heat. The diode is connected across the winding, oriented so it is reverse-biased during steady state operation and does not conduct. When the supply voltage is removed, the voltage spike forward-biases the diode and the reactive current continues to flow through the winding, through the diode, and back into the winding. A diode used in this way is called a freewheeling diode or flyback diode.

Large electromagnets are usually powered by variable current electronic power supplies, controlled by a microprocessor, which prevent voltage spikes by accomplishing current changes slowly, in gentle ramps. It may take several minutes to energize or deenergize a large magnet.

Lorentz forces

In powerful electromagnets, the magnetic field exerts a force on each turn of the windings, due to the Lorentz force q\mathbf{v}\times\mathbf{B} acting on the moving charges within the wire. The Lorentz force is perpendicular to both the axis of the wire and the magnetic field. It can be visualized as a pressure between the magnetic field lines, pushing them apart.

It has two effects on an electromagnet's windings: The field lines within the axis of the coil exert a radial force on each turn of the windings, tending to push them outward in all directions. This causes a tensile stress in the wire. The leakage field lines between each turn of the coil exert an attractive force between adjacent turns, tending to pull them together. The Lorentz forces increase with B^2 .

In large electromagnets the windings must be firmly clamped in place, to prevent motion on power-up and power-down from causing metal fatigue in the windings. In the Bitter electromagnet design (Fig. 2), used in very high-field research magnets, the windings are constructed as flat disks to resist the radial forces, and clamped in an axial direction to resist the axial ones.

Core losses

In alternating current (AC) electromagnets, used in transformers, inductors, and AC motors and generators, the magnetic field is constantly changing. This causes energy losses in their magnetic cores, which is dissipated as heat in the core. The losses stem from two processes: eddy currents and hysteresis losses. Eddy currents: From Faraday's law of induction, a changing magnetic field induces circulating electric currents (eddy currents) inside nearby conductors.

The energy in these currents is dissipated as heat in the electrical resistance of the conductor, so they are a cause of energy loss. Since the magnet's iron core is conductive, and most of the magnetic field is concentrated there, eddy currents in the core are the major problem. Eddy currents are closed loops of current that flow in planes perpendicular to the magnetic field. The energy dissipated is proportional to the area enclosed by the loop.

To prevent them, the cores of AC electromagnets are made of stacks of thin steel sheets, or laminations, oriented parallel to the magnetic field, with an insulating coating on the surface. The insulation layers prevent eddy current from flowing between the sheets. Any remaining eddy currents must flow within the cross-section of each individual lamination, which reduces losses greatly. Another alternative is to use a ferrite core, which is a nonconductor.

Hysteresis losses: Reversing the direction of magnetization of the magnetic domains in the core material each cycle causes energy loss, because of the coercivity of the material. These are called hysteresis losses. The energy lost per cycle is proportional to the area of the hysteresis loop in the BH graph. To minimize this loss, magnetic cores used in transformers and other AC electromagnets are made of "soft" low coercivity materials, such as silicon steel or soft ferrite.

The energy loss per cycle of the alternating current is constant for each of these processes, so the power loss increases linearly with frequency.