Explosimeter

Uses your system voice; voice and rate in settings.

Snapshot

≈ 3 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

An explosimeter is a gas detector which is used to measure the amount of combustible gases present in a sample. When a percentage of the lower explosive limit (LEL) of an atmosphere is exceeded, an alarm signal on the instrument is activated. The device, also called a combustible gas detector, operates on the principle of resistance proportional to heat—a wire is heated, and a sample of the gas is introduced to the hot wire. Combustible gases burn in the presence of the hot wire, thus increasing the resistance and disturbing a Wheatstone bridge, which gives the reading. A flashback arrestor is installed in the device to avoid the explosimeter igniting the sample external to the device. Note, that the detection readings of an explosimeter are only accurate if the gas being sampled has the same characteristics and response as the calibration gas. Most explosimeters are calibrated to methane, hydrogen, and carbon monoxide. Explosimeters are important because workspaces may contain a flammable or explosive atmosphere due to the accumulation of flammable gases or vapors. Sparks from ordinary battery-powered portable equipment, including cameras, cell phones, laptop computers, or anything else located on the job site may serve as an ignition source. The explosimeter warns the user of dangerous atmospheric conditions before a possible explosion can occur.

An explosimeter is a gas detector which is used to measure the amount of combustible gases present in a sample. When a percentage of the lower explosive limit (LEL) of an atmosphere is exceeded, an alarm signal on the instrument is activated. The device, also called a combustible gas detector, operates on the principle of resistance proportional to heat—a wire is heated, and a sample of the gas is introduced to the hot wire. Combustible gases burn in the presence of the hot wire, thus increasing the resistance and disturbing a Wheatstone bridge, which gives the reading. A flashback arrestor is installed in the device to avoid the explosimeter igniting the sample external to the device. Note, that the detection readings of an explosimeter are only accurate if the gas being sampled has the same characteristics and response as the calibration gas. Most explosimeters are calibrated to methane, hydrogen, and carbon monoxide. Explosimeters are important because workspaces may contain a flammable or explosive atmosphere due to the accumulation of flammable gases or vapors. Sparks from ordinary battery-powered portable equipment, including cameras, cell phones, laptop computers, or anything else located on the job site may serve as an ignition source. The explosimeter warns the user of dangerous atmospheric conditions before a possible explosion can occur.

References

External links

https://web.archive.org/web/20050910075254/http://www.marineengineering.org.uk/testequipment/explosimeter.htm (select explosimeter from the left frame) Explosimetry

Text derived from https://en.wikipedia.org/w/index.php?oldid=1288493721 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

2 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.