Flow conditioning ensures that the "real world" environment closely resembles the "laboratory" environment for proper performance of inferential flowmeters like orifice, turbine, coriolis, ultrasonic etc.

Flow conditioning ensures that the "real world" environment closely resembles the "laboratory" environment for proper performance of inferential flowmeters like orifice, turbine, coriolis, ultrasonic etc.

A low-cost handmade flow straightener

A low-cost flow straightener can be constructed using drinking straws, as they have low cost and good efficiency. The MythBusters television show used such a construction for their wind tunnel, as did an experimental wind tunnel at MIT (Maniet). The straws should be cut to equal size and placed in a frame.

Effectiveness of honeycomb

The effectiveness of honeycomb, in reducing the swirl and turbulence level, is studied by simulating the flow field using standard k-ε turbulence model in commercial computational fluid dynamics (CFD). CFD is the most precise and economical approach to estimate the effectiveness of a honeycomb. Computational model A computational domain of honeycomb is created as shown in Fig. 1 We know computationally, it is very difficult to provide the realistic non-uniform flow at the entry of honeycomb as experienced in the experiments. Such random inlet conditions would essentially simulate the realistic case in which air can enter the honeycomb from any direction and at any level of turbulence. Therefore, special domain is designed for introducing practical inlet condition Meshing of Computational Models The solid model of honeycomb is meshed in GAMBIT 2.3.16. As shown in Fig. 2. A structured rectangular mesh is used for the simulation with square honeycomb configuration. Governing equations for mass and momentum conservations for subsonic flow along with the equations for turbulence and porous flow are solved for the honeycomb using commercial CFD. RANS type RNG k-ε model is used for the turbulence modeling. Boundary Conditions The separate domain created upstream of the honeycomb is provided with various inlet conditions to arrive at the disorderly motion at the exit, which should be given as an inlet to the honeycomb cells. This essentially simulates the more realistic case that the flow can enter into the honeycomb from any direction. Specifications of this inlet along with other necessary boundary conditions are mentioned here. Flow at the inlet of the honeycomb shall necessarily have turbulent and swirling motions. Therefore, in order to incorporate these requirements, a separate fluid domain is constructed. Top and bottom circular faces are considered as inlet to this domain to get a flow field with higher magnitude of lateral velocity. This domain is provided with vertical and horizontal cylinders as an obstruction to the inlet to produce sufficient swirling at the exit of this section. A tetrahedral mesh as shown in Fig. 3 with tetrahedral elements is generated for this geometry. The number of nodes are 1,47,666. Three faces of this configuration are specified as inlets with velocity boundary conditions. Fluid velocity at these inlet faces has been so taken that averaged mean velocity at the outlet is 1 m/s, which is in the operational wind tunnel. A pressure outlet boundary condition is used at exit of the settling chamber where pressure at outlet is set to zero for gauge pressure. It is always possible to predict the entire flow field by meshing whole fluid domain; however simulation for the prediction of entire flow field using symmetry boundary condition. This approach reduces the mesh requirement and computational efforts. Therefore, symmetry boundary is used at the periphery of the computational domain. All the solid boundaries in the computational domain are specified as viscous walls with no-slip wall boundary condition. Turbulence intensity profile at the exit of turbulence model is shown in Fig. 4. This figure shows the turbulence intensity and which is maximum at the center (30%) and at the walls is around 16-18%, now this profile is incorporated inside the honeycomb as shown in Fig. 2, the profile of turbulence intensity comes out from the honeycomb is shown in Fig. 5. In this profile we can see that the turbulence intensity is reduced from 30% to 1.2% at the center and 16% to 3.5%, it means the honeycomb effectiveness is very high which is around 96%. The most commonly used description of flow conditions within the pipe is the flow velocity profile. Fig.(1) shows the typical flow velocity profile for natural gas measurement. The shape of the flow velocity profile is given by the following equation, {\frac{U_y}{U_{max}}} = \left [ 1 - \frac{Y}{R} \right ]^{1/n} ---- (1) The value of n determines the shape of the flow velocity profile. The eq.(1) can be used to determine the flow profile's shape within the pipe by fitting a curve to experimentally measured velocity data. In 1993, the transverse flow velocities were being measured within the high pressure natural gas environment using hot wire technology to accomplish the data fit. A fully developed flow profile was used as the reference state for meter calibration and determination of Coefficient of Discharge (Cd). For Reynolds Number 10^5 to 10^6 n is approximately 7.5; for Re of 10^6 , n is approximately 10.0 where a fully developed profile in a smooth pipe was assumed. Since n is a function of Reynolds Number and friction factor, more accurate values of n can be estimated by using the eq.(2), n = \frac {1}{\sqrt{f}}. ---- (2) Where, f is friction factor. A good estimate of a fully developed velocity profile can be used for those without adequate equipment to actually measure the flow velocities within the pipe. The following straight pipe equivalent length in eq.(3) was utilized to ensure a fully developed flow profile exists. Pipe Diameters = 4.4D \left [R_e \right ]^{1/6} ---- (3) In eq.(3) the pipe lengths required is significant, hence we need some devices that can able to condition the flow over a shorter pipe length allowing metering packages to be cost competitive and accurate. Here the velocity flow profile is generally three-dimensional. Normally the description requires no axial orientation indication if the profile is asymmetric and if it does exists, then axial orientation with respect to some suitable plane of reference is required. Asymmetry exists downstream of installation effects such as elbows or tees. Usually, the velocity flow profile is described on two planes 90° apart. Using the latest software technology a full pipe cross sectional description of the velocity profile is possible provided sufficient data points are given. q_m = (C_d)(E_v)(Y)\left [ \frac{\pi}{4} \right ](d)^2 \sqrt {2 \rho \Delta P} ----(4) Where, q_m = Mass flow C_d = Coefficient of discharge E_v = Velocity of approach factor Y = Expansion factor d = orifice diameter \rho = density of the fluid \Delta P = differential pressure Now to use the eq.(4), the flow field entering the orifice plate must be free of swirl and exhibit a fully developed flow profile. API 14.3 (1990) and ISO standards determined the Coefficient of Discharge by completing numerous calibration tests where the indicated mass flow was compared to the actual mass flow to determine coefficient of discharge. In all testing the common requirement was a fully developed flow profile entering the orifice plate. Accurate standard compliant meter designs must therefore ensure that a swirl free, fully developed flow profile is impinging on the orifice plate. There are numerous methods available to accomplish this. These methods are commonly known as "flow conditioning". The first installation option is to revert to no flow conditioning, but adequate pipe lengths must be provided by the eq.(2) mentioned above. This generally makes the manufacturing costs for a flow measurement facility unrealistic due to excessively long meter tubes; Imagine meter tubes 75 diameters long. The second and most well known option is the 19-tube tube-bundle flow conditioner. The majority of flow installations in North America contain the tube bundle. With the help of hot wire, pitot tube and laser-based computerized measurement systems which allow detailed measurement of velocity profile and turbulence intensity; we know that the tube bundle does not provide fully developed flow. Therefore, this device is causing biased orifice flow measurement. As a result of these recent findings, few tube bundles are specified for flow measurement and reduce the use of such device. Numerous references are available providing performance results indicating less than acceptable meter performance when using the conventional 19-tube test bundle. The individual results should be reviewed to ascertain details such as beta ratio, meter tube lengths, Re and test conditions. The general indications are that the conventional tube bundle will cause the orifice installation to over register flow values up to 1.5% when the tube bundle is 1 pipe diameter to approximately 11 pipe diameters from the orifice plate. This is caused by a flat velocity profile that creates higher differential pressures than with a fully developed profile. There is a crossover region from approximately 10 to 15 pipe diameters where the error band is approximately zero. Then a slight under-registration of flows occurs for distances between approximately 15 to 25 pipe diameters. This is due to a peaked velocity profile that creates lower differential pressures than a fully developed profile. At distances greater than 25 pipe diameters the error asymptotes to zero. Fig.(3) showing the Conventional Tube Bundle Performance explaining typical characteristic behavior of the popular 19 tube, tube-bundle. An additional drawback of the conventional 19 tube, tube bundle is variation in sizing. The conventional tube bundle provides errors very much dependent on installation details, that is, the elbows on and out of plane, tees, valves and distances from the last pipe installation to the conditioner and conditioner to the orifice plate. These errors have a great significance. Therefore, the latest findings regarding conventional tube bundle performance should be reviewed prior to meter station design and installation. The final installation option for orifice metering is perforated plate flow conditioners. There is a variety of perforated plates have entered the market. These devices generally are designed to rectify the drawbacks of the conventional tube bundle (accuracy and repeatability insufficiency). The reader is cautioned to review the performance of the chosen perforated plate carefully prior to installation. A flow conditioner performance test guideline should be utilized to determine performance. The key elements of a flow conditioner test are - Perform a baseline calibration test with an upstream length of 70 to 100 pipe diameters of straight meter tube. The baseline Coefficient of Discharge values should be within the 95% confidence interval for the RG orifice equation (i.e. the coefficient of discharge equation as provided by AGA-3). Select values of upstream meter tube length, and flow conditioner location, to be used for the performance evaluation. Install the flow conditioner at the desired location. First, perform a test for either the two 90° elbows out-of-plane installation, or the high swirl installation for \beta = 0.40 and for \beta = 0.67. This test will show whether the flow conditioner removes swirl from the disturbed flow. If the \Delta Cd is within the acceptable region for both values of \beta i.e. 0.40 and 0.67, and if the Cd results vary as (\beta)^{3.5} , then the conditioner is successful in removing swirl. The tests for the other three installations namely, good flow conditions, partly closed valve and highly disturbed flow) may be performed for \beta = 0.67, and the results for other (i ratios predicted from the \Delta Cd - (\beta)^{3.5} correlation. Otherwise, the tests should be performed for a range of p ratios between 0.20 and 0.75. Perform test and determine the flow conditioner performance for the flow conditioner installed in good flow conditions, downstream of a half closed valve, and for either the double 90° elbow out-of-plane or the high swirl installation. \bar {V}_{flow} = \left [ \frac{1}{T_{ab}} - \frac{1}{T_{ba}} \right ]\left [ \frac{Dist_{Sound path}}{2\cos \phi} \right ] ----(5) The case of no flow gives the actual path of the sound when there is zero flow (by equating eq.(5) to zero). In case of theoretical flow profile, say a uniform velocity flow profile where the no-slip condition on the pipe walls is not applied, Fig.(6) shows Ultrasonic Meter sound path - uniform velocity profile which illustrates the resultant sound path. A theoretical derivation of the Mean velocity equation for this sound path becomes much more complicated. In case of a perfect fully developed real velocity profile of Ultrasonic meter which is shown in Fig.(7) indicating a possible sound path as a result of an installation in a real flow. Here a mathematical derivation for this Ultrasonic meter is also becomes very complicated. Developing a robust flow algorithm to calculate the mean flow velocity for the sound path can be quite complicated. Now add to this; sound path reflection from the pipe wall, multipaths to add degrees of freedom, swirl and departure from axisymmetric fully developed flow profile and the problem of integrating the actual velocity flow profile to yield volume flow rate can be an accomplishment. Hence the real performance of ultrasonic meters downstream of perturbations, and the need for calibrations is required.

Bibliography

ANSYS Inc., 2007. Release 11 Documentation for ANSYS Workbench. Cermak, J.E., 2003. Wind-tunnel development and trends in applications to civil engineering. J. Wind Eng. Ind. Aerodyn. 91 (3), 355–370. Cermak, J.E., Cochran, L.S., 1992. Physical modeling of the atmospheric surface layer. J. Wind Eng. Ind. Aerodyn. 41–44, 935–946. Collar, A.R., 1939. The effect of a gauze on velocity distribution in a uniform duct. Aeronaut. Res. Counc. Rep. Memo No. 1867. Desai, S.S., 2003. Relative roles of computational fluid dynamics and wind tunnel testing in the development-of aircraft. Curr. Sci. 84 (1), 49–64. Derbunovich, G.I., Zemskaya, A.S., Repik, E.U., Sosedko, Y.P., 1993. Optimum Conditions of Turbulence Reduction with Screens, Mechanics of Nonuniform and Turbulent Flows. Nauka, Moscow, pp. 35. Dryden, H.I., Schubauer, G.B., 1947. The use of damping screens for the reduction of wind tunnel turbulence. J. Aeronautical Sci. 14, 221–228. Farell, C., Youssef, S., 1996. Experiments on turbulence management using screens and honeycombs. ASME J. Fluids Eng. 118, 26–32. Ghani, S.A.A.A., Aroussi, A., Rice, E., 2001. Simulation of road vehicle natural environment in a climatic wind tunnel. Simul. Pract. Theory 8 (6–7), 359–375. Gordon, R., Imbabi, M.S., 1998. CFD simulation and experimental validation of a new closed circuit wind/water tunnel design. J. Fluids Eng. Trans. ASME 120 (2), 311–318. Groth, J., Johansson, A., 1988. Turbulence reduction by screens. J. Fluids Mech. 197, 139–155. Hansen, S.O., Sorensen, E.G., 1985. A new boundary-layer wind tunnel at the Danish Maritime Institute. J. Wind Eng. Ind. Aerodyn. 18, 213–224.

Text derived from https://en.wikipedia.org/w/index.php?oldid=1322625910 under CC BY-SA 4.0; modifications have been made.