Lesson plan

Fluo-3

{{Chembox | ImageFile = Fluo-3.svg | ImageSize = 200px | PIN = 2,2′- {[2-(2- {2-[Bis(carboxymethyl)amino]-5-(2,7-dichloro-6-hydroxy-3-oxo-3H-xanthen-9-yl)phenoxy}ethoxy)-4-methylphenyl]azanediyl}diacetic acid | OtherNames = |Section1= |Section2= |Section3= }} Fluo-3 is a fluorescence indicator of intracellular calcium (Ca 2+ ), developed by Roger Y. Tsien. It is used to measure Ca 2+ inside living cells in flow cytometry, and confocal laser scanning microscopy using visible light excitation (compatible with argon laser sources operating at 488 nm). Fluo-3 and derivatives (Fluo-4, Fluo-5 etc) have also been widely used with two-photon excitation microscopy. Fluo-3 is an essentially nonfluorescent compound, but upon binding of Ca 2+ its fluorescence increases sharply with an emission maximum at 525 nm suitable for conventionally used detectors designed for fluorescein isothiocyanate (FITC) measurements. This large change in fluorescence coupled with a good yield of photons provides very high contrast which allowed the detection of microscopic Ca 2+ release events inside cells called "Calcium sparks". Whereas the salts of fluo-3 are unable to penetrate cells, loading can be achieved using its acetoxymethyl (AM) ester derivative. Once inside the cell, unspecific esterases cleave the ester effectively trapping fluo-3.…

Back to article

Article summary

{{Chembox | ImageFile = Fluo-3.svg | ImageSize = 200px | PIN = 2,2′- {[2-(2- {2-[Bis(carboxymethyl)amino]-5-(2,7-dichloro-6-hydroxy-3-oxo-3H-xanthen-9-yl)phenoxy}ethoxy)-4-methylphenyl]azanediyl}diacetic acid | OtherNames = |Section1= |Section2= |Section3= }} Fluo-3 is a fluorescence indicator of intracellular calcium (Ca 2+ ), developed by Roger Y. Tsien. It is used to measure Ca 2+ inside living cells in flow cytometry, and confocal laser scanning microscopy using visible light excitation (compatible with argon laser sources operating at 488 nm). Fluo-3 and derivatives (Fluo-4, Fluo-5 etc) have also been widely used with two-photon excitation microscopy. Fluo-3 is an essentially nonfluorescent compound, but upon binding of Ca 2+ its fluorescence increases sharply with an emission maximum at 525 nm suitable for conventionally used detectors designed for fluorescein isothiocyanate (FITC) measurements. This large change in fluorescence coupled with a good yield of photons provides very high contrast which allowed the detection of microscopic Ca 2+ release events inside cells called "Calcium sparks". Whereas the salts of fluo-3 are unable to penetrate cells, loading can be achieved using its acetoxymethyl (AM) ester derivative. Once inside the cell, unspecific esterases cleave the ester effectively trapping fluo-3.…

Key claims

No claims recorded.

Discussion questions

  1. Summarise the article in your own words. Which single claim would you verify first, and why?
  2. Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
  3. If two sources disagreed about one of these facts, what would you need in order to trust one over the other?

Bibliography

No sources recorded.

Key claims and bibliography are generated from the same tracked claims and sources as the article page.