Fluorescence upconversion
≈ 2 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
Fluorescence upconversion (FU) is an ultrafast laser spectroscopic technique. It is a variant of sum-frequency generation (of which the second-harmonic generation (SHG) is a special case) but applied to the detection of the incoherent fluorescence. It is therefore closely related to the Optical Kerr Gating (OKG) technique.
FU has become a widely used tool in the field of Femtochemistry, the study of chemical reactions on very short timescales. Fluorescence upconversion should not be confused with photon upconversion, sometimes called upconversion fluorescence.
Fluorescence upconversion (FU) is an ultrafast laser spectroscopic technique. It is a variant of sum-frequency generation (of which the second-harmonic generation (SHG) is a special case) but applied to the detection of the incoherent fluorescence. It is therefore closely related to the Optical Kerr Gating (OKG) technique.
FU has become a widely used tool in the field of Femtochemistry, the study of chemical reactions on very short timescales. Fluorescence upconversion should not be confused with photon upconversion, sometimes called upconversion fluorescence.
Briefly, a fairly strong pump pulse excites the sample, generating the fluorescence (at a frequency ν F ) which is collected and focused in a nonlinear optical crystal. In parallel, an intense probe pulse (also called gate pulse, at a frequency ν G ) is focused and superposed with the fluorescence in the crystal.
The instantaneous interaction of the fluorescence and the probe pulse in the crystal allows the generation of sum-frequency light at a frequency ν S = ν G + ν F (where ν is the frequency). It is important that the fluorescence and the probe pulses arrive simultaneously (or nearly) in the crystal - to this purpose the probe pulse is directed through a controllable optical delay stage.
Simply speaking, the probe (gate) pulse represents a "time window" during which the fluorescence is detected. An important advantage of this technique is that the intensity of the detected signal (the sum frequency light) is directly proportional to the intensity of the fluorescence.
Since the sum frequency light appears at shorter wavelengths than the fluorescence, a monochromator or an optical filter can be used to suppress both fluorescence and diffused laser light, allowing for a high signal-to-noise ratio when detected, for example, by a photo-multiplier.
Text derived from https://en.wikipedia.org/w/index.php?oldid=1333159925 under CC BY-SA 4.0; modifications have been made.