Lesson plan
Flutter valve
In respiratory medicine, a flutter valve (also Pneumostat valve, and Heimlich valve) is a one-way check valve used to prevent airflow back into a chest tube, and usually is applied to drain air from a pneumothorax. The design of the flutter valve features a rubber sleeve in a plastic case, where the rubber sleeve is arranged so that when air flows through the valve the sleeve opens and allows the outwards airflow from the body of the patient; however, when the airflow is reversed, the rubber sleeve closes and halts backwards airflow into the body of the patient. The construction of the flutter valve enables it to function as a one-way valve allowing airflow, or the flow of a fluid, in only one direction along the drainage tube. The end of the drainage tube is placed inside the chest cavity of the patient — into the air mass or into the fluid mass to be drained from the thorax. The flutter valve is placed in the appropriate orientation (designed so that the valve can only be connected in the appropriate orientation) and the pneumothorax is thus evacuated from the chest of the patient. Usage of the flutter valve presents potential problems such as clogging of the chest tube, which might provoke the recurrence of the pneumothorax or the subcutaneous emphysema, which can lead to empyema.…
Article summary
In respiratory medicine, a flutter valve (also Pneumostat valve, and Heimlich valve) is a one-way check valve used to prevent airflow back into a chest tube, and usually is applied to drain air from a pneumothorax. The design of the flutter valve features a rubber sleeve in a plastic case, where the rubber sleeve is arranged so that when air flows through the valve the sleeve opens and allows the outwards airflow from the body of the patient; however, when the airflow is reversed, the rubber sleeve closes and halts backwards airflow into the body of the patient. The construction of the flutter valve enables it to function as a one-way valve allowing airflow, or the flow of a fluid, in only one direction along the drainage tube. The end of the drainage tube is placed inside the chest cavity of the patient — into the air mass or into the fluid mass to be drained from the thorax. The flutter valve is placed in the appropriate orientation (designed so that the valve can only be connected in the appropriate orientation) and the pneumothorax is thus evacuated from the chest of the patient. Usage of the flutter valve presents potential problems such as clogging of the chest tube, which might provoke the recurrence of the pneumothorax or the subcutaneous emphysema, which can lead to empyema.…
Key claims
No claims recorded.
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?
Bibliography
No sources recorded.
Key claims and bibliography are generated from the same tracked claims and sources as the article page.