{
  "id": "enwiki-001373534756",
  "slug": "humidity",
  "title": "Humidity",
  "qid": "",
  "lead": "Humidity is the concentration of water vapor present in the air. Water vapor, the gaseous state of water, is generally invisible to the naked eye. Humidity indicates the likelihood for precipitation, dew, or fog to be present. Humidity depends on the temperature and pressure of the system of interest. The same amount of water vapor results in higher relative humidity in cool air than warm air. A related parameter is the dew point. The amount of water vapor needed to achieve saturation increases as the temperature increases. As the temperature of a parcel of air decreases it will eventually reach the saturation point without adding or losing water mass. The amount of water vapor contained within a parcel of air can vary significantly. For example, a parcel of air near saturation may contain 8 g of water per cubic metre of air at , and 28 g of water per cubic metre of air at Three primary measurements of humidity are widely employed: absolute, relative, and specific. Absolute humidity is the mass of water vapor per volume of air (in grams per cubic meter). Relative humidity, often expressed as a percentage, indicates a present state of absolute humidity relative to a maximum humidity given the same temperature. Specific humidity is the ratio of water vapor mass to total moist air parcel mass. Humidity plays an important role for surface life.…",
  "body": "Humidity is the concentration of water vapor present in the air. Water vapor, the gaseous state of water, is generally invisible to the naked eye. Humidity indicates the likelihood for precipitation, dew, or fog to be present. Humidity depends on the temperature and pressure of the system of interest. The same amount of water vapor results in higher relative humidity in cool air than warm air. A related parameter is the dew point. The amount of water vapor needed to achieve saturation increases as the temperature increases. As the temperature of a parcel of air decreases it will eventually reach the saturation point without adding or losing water mass. The amount of water vapor contained within a parcel of air can vary significantly. For example, a parcel of air near saturation may contain 8&nbsp;g of water per cubic metre of air at , and 28&nbsp;g of water per cubic metre of air at Three primary measurements of humidity are widely employed: absolute, relative, and specific. Absolute humidity is the mass of water vapor per volume of air (in grams per cubic meter). Relative humidity, often expressed as a percentage, indicates a present state of absolute humidity relative to a maximum humidity given the same temperature. Specific humidity is the ratio of water vapor mass to total moist air parcel mass. Humidity plays an important role for surface life. For animal life dependent on perspiration (sweating) to regulate internal body temperature, high humidity impairs heat exchange efficiency by reducing the rate of moisture evaporation from skin surfaces. This effect can be calculated using a heat index table, or alternatively using a similar humidex. The notion of air \"holding\" water vapor or being \"saturated\" by it is often mentioned in connection with the concept of relative humidity. This, however, is misleading—the amount of water vapor that enters (or can enter) a given space at a given temperature is almost independent of the amount of air (nitrogen, oxygen, etc.) that is present. Indeed, a vacuum has approximately the same equilibrium capacity to hold water vapor as the same volume filled with air; both are given by the equilibrium vapor pressure of water at the given temperature. There is a very small difference described under \"Enhancement factor\" below, which can be neglected in many calculations unless great accuracy is required. AH = \\frac{m_{\\text{H}_2\\text{O}}}{V_\\text{net}}. In the equation above, the absolute humidity of a mass of air varies with changes in air temperature or pressure. This makes the (volumetric) absolute humidity unsuitable for some applications. Air is a gas, and the volume of a specific amount varies with pressure and temperature, per Boyle's law. Absolute humidity is defined as water mass per volume of air, and a given mass of air will grow or shrink as the temperature or pressure varies; thus, the absolute humidity of a mass of air will vary due to changes in temperature or pressure, even when the proportion of water in that mass of air (its specific humidity) remains constant. Because of the variability of absolute humidity with changes in air temperature or pressure, use of the absolute humidity as defined above is inappropriate for computations in chemical engineering, such as drying, where temperature variations might be significant. As a result, absolute humidity in chemical engineering may refer to mass of water vapor per unit mass of dry air, also known as the \"humidity ratio\" or \"mass mixing ratio\" (see also Specific humidity below), which is better suited for heat and mass balance calculations. The ratio of the mass of water per unit volume as defined in the equation above is also called the \"volumetric humidity\", which may be the preferred term in such contexts. Because of the potential confusion, British Standard BS 1339 recommends avoiding the term \"absolute humidity\", deprecating it in favor of \"volumetric humidity\", \"specific humidity\", and \"mixing ratio\". In general, when using absolute humidity, units should always be carefully checked to determine whether the volumetric or specific humidity is being used; many humidity charts are given in g/kg or kg/kg, but any mass units may be used. RH = \\frac{P_w}{P_s} where P s is the saturation pressure of water at temperature T 1 . Relative humidity varies with any change in the temperature or pressure of the air: colder air can contain less vapour, and water will tend to condense out of the air more at lower temperatures. So changing the temperature of air can change the relative humidity, even when the specific humidity remains constant. If two parcels of air have the same specific humidity and temperature but different pressures, the parcel at the higher pressure will have the higher relative humidity. Cooling air increases the relative humidity. If the relative humidity rises to 100% (the dew point) and there is an available surface or particle, the water vapour will condense into liquid or deposit into ice. Likewise, warming air decreases the relative humidity. Warming some air containing a fog may cause that fog to evaporate, as the droplets are prone to total evaporation due to the lowering partial pressure of water vapour in that air, as the temperature rises. Relative humidity only considers the invisible water vapour. Mists, clouds, fogs and aerosols of water do not count towards the measure of relative humidity of the air, although their presence is an indication that a body of air may be close to the dew point. Relative humidity is normally expressed as a percentage; a higher percentage means that the air–water mixture is more humid. At 100% relative humidity, the air is saturated and is at its dew point. In the absence of a foreign body on which droplets or crystals can nucleate, the relative humidity can exceed 100%, in which case the air is said to be supersaturated. Introduction of some particles or a surface to a body of air above 100% relative humidity will allow condensation or ice to form on those nuclei, thereby removing some of the vapour and lowering the humidity. In a scientific notion, the relative humidity ( RH or \\phi ) of an air-water mixture is defined as the ratio of the partial pressure of water vapor ( p ) in air to the saturation vapor pressure ( p_s ) of water at the same temperature, usually expressed as a percentage: \\phi = 100\\% \\cdot p/p_s Relative humidity is an important metric used in weather forecasts and reports, as it is an indicator of the likelihood of precipitation, dew, or fog. In hot summer weather, a rise in relative humidity increases the apparent temperature to humans (and other animals) by hindering the evaporation of perspiration from the skin. For example, according to the heat index, a relative humidity of 75% at air temperature of would feel like . Because wood changes shape with changes in humidity, relative humidity is used to evaluate moisture content and size changes in wood, such as making allowances for seasonal movement in wood floors. e^*_w = \\left(1.0007 + 3.46 \\times 10^{-6} P\\right) \\times 6.1121\\, e^{17.502 T/(240.97 + T)}, where T is the dry-bulb temperature expressed in degrees Celsius (°C), P is the absolute pressure expressed in millibars, and e^*_w is the equilibrium vapor pressure expressed in millibars. Buck has reported that the maximal relative error is less than 0.20% between when this particular form of the generalized formula is used to estimate the equilibrium vapor pressure of water. There are various devices used to measure and regulate humidity. Calibration standards for the most accurate measurement include the gravimetric hygrometer, chilled mirror hygrometer, and electrolytic hygrometer. The gravimetric method, while the most accurate, is very cumbersome. For fast and very accurate measurement the chilled mirror method is effective. For process on-line measurements, the most commonly used sensors nowadays are based on capacitance measurements to measure relative humidity, frequently with internal conversions to display absolute humidity as well. These are cheap, simple, generally accurate and relatively robust. All humidity sensors face problems in measuring dust-laden gas, such as exhaust streams from clothes dryers. Humidity is also measured on a global scale using remotely placed satellites. These satellites are able to detect the concentration of water in the troposphere at altitudes between . Satellites that can measure water vapor have sensors that are sensitive to infrared radiation. Water vapor specifically absorbs and re-radiates radiation in this spectral band. Satellite water vapor imagery plays an important role in monitoring climate conditions (like the formation of thunderstorms) and in the development of weather forecasts. f_W = \\frac{e'_w}{e^*_w}. The enhancement factor is equal to unity for ideal gas systems. However, in real systems, the interaction effects between gas molecules result in a small increase of the equilibrium vapor pressure of water in air relative to equilibrium vapor pressure of pure water vapor. Therefore, the enhancement factor is normally slightly greater than unity for real systems. The enhancement factor is commonly used to correct the equilibrium vapor pressure of water vapor when empirical relationships, such as those developed by Wexler, Goff, and Gratch, are used to estimate the properties of psychrometric systems. Buck has reported that, at sea level, the vapor pressure of water in saturated moist air amounts to an increase of approximately 0.5% over the equilibrium vapor pressure of pure water. Humans can be comfortable within a wide range of humidities depending on the temperature—from 30 to 70% —but ideally not above the Absolute (60&nbsp;°F Dew Point), between 40% and 60%. In general, higher temperatures will require lower humidities to achieve thermal comfort compared to lower temperatures, with all other factors held constant. For example, with clothing level = 1, metabolic rate = 1.1, and air speed 0.1&nbsp;m/s, a change in air temperature and mean radiant temperature from 20&nbsp;°C to 24&nbsp;°C would lower the maximum acceptable relative humidity from 100% to 65% to maintain thermal comfort conditions. The CBE Thermal Comfort Tool can be used to demonstrate the effect of relative humidity for specific thermal comfort conditions and it can be used to demonstrate compliance with ASHRAE Standard 55–2017. Some people experience difficulty breathing in humid environments. Some cases are related to respiratory conditions such as asthma, where humidity as low as 50% was shown to meaningfully increase risks for dyspnea, cough and exercise induced bronchoconstriction. Other cases may be the product of anxiety. Affected people will often hyperventilate in response, causing sensations of numbness, faintness, and loss of concentration, among others. Air conditioning reduces discomfort by reducing not just temperature but humidity as well. Heating cold outdoor air can decrease relative humidity levels indoors to below 30%. According to ASHRAE Standard 55-2017: Thermal Environmental Conditions for Human Occupancy, indoor thermal comfort can be achieved through the PMV method with relative humidities ranging from 0% to 100%, depending on the levels of the other factors contributing to thermal comfort. However, the recommended range of indoor relative humidity in air conditioned buildings is generally 30–60%. Current map of global relative humidity",
  "categories": [
    "110894820",
    "20154532",
    "20383303",
    "22956302",
    "23025686",
    "23118434",
    "23603337",
    "24043274",
    "24623845",
    "24745113",
    "24745122",
    "29309381",
    "29309441",
    "33256317",
    "50701333",
    "56372482",
    "69881745",
    "89061576",
    "95494862"
  ],
  "license": "CC BY-SA 4.0",
  "source_uri": "https://en.wikipedia.org/w/index.php?oldid=1373534756",
  "content_hash": "",
  "created_at": null,
  "updated_at": 1788698411.0,
  "claims": [],
  "contradictions": [],
  "confidence": 0.6,
  "csl": {
    "id": "enwiki-001373534756",
    "type": "webpage",
    "title": "Humidity",
    "author": [
      {
        "family": "Anticloud FZ LLE",
        "literal": "Anticloud FZ LLE"
      }
    ],
    "container-title": "encyclopegia.org",
    "publisher": "Anticloud FZ LLE",
    "publisher-place": "Dubai, United Arab Emirates",
    "URL": "https://encyclopegia.org/a/humidity",
    "issued": {
      "date-parts": [
        [
          2026,
          11,
          20
        ]
      ]
    },
    "accessed": {
      "date-parts": [
        [
          2026,
          11,
          20
        ]
      ]
    },
    "license": "CC BY-SA 4.0",
    "DOI": "eo1:enwiki-001373534756",
    "isBasedOn": "https://en.wikipedia.org/w/index.php?oldid=1373534756",
    "note": "Immutable snapshot enwiki-001373534756"
  }
}