Hyperpolarization is the spin polarization of the atomic nuclei of a material in a magnetic field far beyond thermal equilibrium conditions determined by the Boltzmann distribution. It can be applied to gases such as and , and small molecules where the polarization levels can be enhanced by a factor of 10 4 –10 5 above thermal equilibrium levels.

Hyperpolarized noble gases are typically used in magnetic resonance imaging (MRI) of the lungs. Hyperpolarized small molecules are typically used for in vivo metabolic imaging. For example, a hyperpolarized metabolite can be injected into animals or patients and the metabolic conversion can be tracked in real-time.

Other applications include determining the function of the neutron spin-structures by scattering polarized electrons from a very polarized target ( 3 He), surface interaction studies, and neutron polarizing experiments.

Spin-exchange optical pumping

In order to increase the polarization level above thermal equilibrium, the populations of the spin states must be altered. In the absence of magnetic field, the two spin states of a spin I = nuclei are in the same energy level, but in the presence of a magnetic field, the energy levels split into m s = ± energy levels (Figure 2).

Here, m s is the spin angular momentum with possible values of + (spin up) or − (spin down), often drawn as vectors pointing up or down, respectively. The difference in population between these two energy levels is what produces an NMR signal.

For example, the two electrons in the spin down state cancel two of the electrons in the spin up state, leaving only one spin up nucleus to be detected with NMR. However, the populations of these states can be altered via hyperpolarization, allowing the spin up energy level to be more populated and therefore increase the NMR signal.

This is done by first optically pumping alkali metal, then transferring the polarization to a noble gas nucleus to increase the population of the spin up state. The absorption of laser light by the alkali metal is the first process in SEOP.

Left-circularly polarized light tuned to the D 1 wavelength of the alkali metal excites the electrons from the spin down 2 S 1/2 (m s =−1/2) state into the spin up 2 P 1/2 (m s =+1/2) state, where collisional mixing then occurs as the noble gas atoms collide with the alkali metal atoms and the m s =−1/2 state is partially populated (Figure 3). Circularly polarized light is necessary at low magnetic fields because it allows only one type of angular momentum to be absorbed, allowing the spins to be polarized.

Relaxation then occurs from the excited states (m s =±1/2) to the ground states (m s =±1/2) as the atoms collide with nitrogen, thus quenching any chance of fluorescence and causing the electrons to return to the two ground states in equal populations. Once the spins are depolarized (return to the m s =−1/2 state), they are excited again by the continuous wave laser light and the process repeats itself.

In this way, a larger population of electron spins in the m s =+1/2 state accumulates. The polarization of the rubidium, P Rb , can be calculated by using the formula below: {P_{Rb}}={{\mathrm{n}_\uparrow-\mathrm{n}_\downarrow}\over{\mathrm{n}_\uparrow+\mathrm{n}_\downarrow}} Where n ↑ and n ↓ and are the number of atoms in the spin up (m S =+1/2) and spin down (m S =−1/2) 2 S 1/2 states.

Next, the optically pumped alkali metal collides with the noble gas, allowing for spin exchange to occur where the alkali metal electron polarization is transferred to the noble gas nuclei (Figure 4). There are two mechanisms in which this can occur.

The angular momentum can be transferred via binary collisions (Figure 4A, also called two-body collisions) or while the noble gas, N 2 buffer gas, and vapor phase alkali metal are held in close proximity via van der Waals forces (Figure 4B, also called three body collisions). In cases where van der Waals forces are very small compared to binary collisions (such is the case for 3 He), the noble gas and alkali metal collide and polarization is transferred from the AM to the noble gas.

Binary collisions are also possible for 129 Xe. At high pressures, van der Waals forces dominate, but at low pressures binary collisions dominate. \mathrm{P}_N(\mathrm{t})=\left \langle\mathrm{P}_A\right \rangle \left ( \frac{\gamma_{SE}}{\gamma_{SE}+\Gamma} \right ) [1-e^{(\gamma_{SE}+\Gamma)\mathrm{t}}] Where ⟨P A ⟩ is the alkali metal polarization, γ SE is the spin exchange rate, and Γ is the longitudinal relaxation rate of the noble gas.

Relaxation of the nuclear polarization can occur via several mechanisms and is written as a sum of these contributions: \Gamma=\Gamma_t+\Gamma_p+\Gamma_g+\Gamma_w Where Γ t , Γ p , Γ g , and Γ w represent the relaxation from the transient Xe 2 dimer, the persistent Xe 2 dimer, diffusion through gradients in the applied magnetic field, and wall relaxation, respectively. In most cases, the largest contributors to the total relaxation are persistent dimers and wall relaxations.

A Xe 2 dimer can occur when two Xe atoms collide and are held together via van der Waals forces, and it can be broken when a third atom collides with it. It is similar to Xe-Rb during spin exchange (spin transfer) where they are held in close proximity to each other via van der Waals forces.

Wall relaxation is when the hyperpolarized Xe collides with the walls of the cell and is de-polarized due to paramagnetic impurities in the glass. The buildup time constant, Γ B , can be measured by collecting NMR spectra at time intervals falling within the time it takes to reach steady-state polarization (i.e. the maximum polarization that can be achieved, seen by the maximum signal output).

The signal integrals are then plotted over time and can be fit to obtain the buildup time constant. Collecting a buildup curve at several different temperatures and plotting the values as a function of alkali metal vapor density (since vapor density increases with an increase in cell temperature) can be used to determine the spin destruction rate and the per-atom spin exchange rate using: \Gamma_B=\gamma'\times[AM]+\Gamma_{SD} Where γ' is the per-atom spin exchange rate, [AM] is the alkali metal vapor density, and Γ SD is the spin destruction rate.

This plot should be linear, where γ' is the slope and Γ SD is the y-intercept. \frac{1}{\mathrm{T}_1}=\left ( \frac{1}{T_1} \right )_{CR}+\left ( \frac{1}{T_1} \right )_{MFI}+\left ( \frac{1}{T_1} \right )_{O2} Where the three contributing terms are for collisional relaxation (CR), magnetic field inhomogeneity (MFI) relaxation, and relaxation caused by the presence of paramagnetic oxygen (O2). The T 1 duration could be anywhere from minutes to several hours, depending on how much care is put into lessening the effects of CR, MFI, and O 2 .

The last term has been quantified to be 0.360 s −1 amagat −1 , but the first and second terms are hard to quantify since the degree of their contribution to the overall T 1 is dependent on how well the experimental setup and cell are optimized and prepared. \omega=\gamma\mathrm{B}_0 Where ω is the Larmour frequency, or desired detection frequency, γ is the gyromagnetic ratio of the nuclei of interest, and B 0 is the magnetic field required to detect the nuclei at the desired frequency. A set of four electromagnetic coils can also be used (i.e. from Acutran) and other coil designs are being tested.

In the past, laser technology was a limiting factor for SEOP, where only a couple alkali metals could be used due to the lack of, for example, cesium lasers. However, there have been several new developments, including better cesium lasers, higher power, narrower spectral width, etc. which are allowing the reaches of SEOP to increase.

Nevertheless, there are several key features required. Ideally, the laser should be continuous wave to ensure the alkali metal and noble gas remains polarized at all times. In order to induce this polarization, the laser light must be circularly polarized in the direction which allows the electrons to become spin polarized.

This is done by passing the laser light through a polarizing beam splitter to separate the s and p components, then through a quarter wave plate, which converts the linearly polarized light into circularly polarized light. According to the scientist Ostwald, solubility is defined as the partition coefficient of the gas absorbed to the volume of the absorbing liquid.

The solubility of Xenon, S Xe(g) = V absorbed amount of Xe(g) /V absorbing liquid at standard temperature and pressure (STP). Solubility of Xenon in water medium 11% means at 25 °C 11 mL Xenon gas could be absorbed by 100 mL of water.

Xenon atomic size is large and outer shell electrons are far from the nuclei, outermost electron is highly prone to be polarized specially lipid environment. Table 2 shows Xenon solubility in water medium at 37 °C is 8% but fat tissue in vivo environment the solubility value is 130%. Solubility leads the Xenon using in biological system as a contrasting agent.

Solvent effect of xenon is very large for of 129 Xenon by the fact of solubility (table 2). Chemical shift value range for Xenon is more than 7500 ppm. However solvent effect is limited range for 1 H & 13 C (MRI active nuclei) because of low chemical shift value range for 1 H is 20 ppm and for 13 C is 300 ppm.

Therefore, using the 129 Xe is preferred. Figure-9 below, In NMR experimental data, there are different chemical shift values for different tissues in in vivo environment. All peaks are positioned through such a big range of chemical shift values for 129 Xe is viable.

Because 129 Xe has long range up-to 1700ppm chemical shift value range in NMR data. Other important spectral information includes: Figure 9. NMR data for Xe-129 biosensor in in vivo biological system.

Naturally 129 Xe NMR peak has been counted as reference at 0.0ppm. When 129 Xe incorporated and bind with the Cryptophane-A molecule, then the chemical shift value in NMR acquisition shifted to around 70ppm. If hyperpolarized 129 Xe gas is dissolved into the brain, then five NMR spectral peaks can be observed.

Among them top sharp peak at 194.7ppm. In addition, at 189 ppm peak come out from the non-brain tissues. Another two peaks are still unknown at 191.6 ppm and 197.8 ppm.

At 209.5 ppm smaller but broad peak has been found in NMR data when 129 Xe was dissolved in the blood stream. Hyperpolarized 129 Xe is very sensitive detector of biomarker (form of cancer in living system). The nuclear spin polarization of 129 Xe or in generally for noble gases we can increase up to fivefold via SEOP technique.

Using SEOP hyperpolarization technique, we can get images of uptake of xenon in the human brain tissue. (Figure-10) 129 Xe (g) shows satisfactory enhancement in polarization during SEOP compared to the thermal enhancement in polarization. This is demonstrated by the experimental data values when NMR spectra are acquired at different magnetic field strengths.

A couple of important points from experimental data are: The 129 Xe polarization has increased about 144,000-fold in SEOP tech. over thermally enhanced for 1 H polarization in NMR experiment. Both experiments that showed this have been done in identical conditions and using same radio frequency during NMR experiment.

A similar value of 140,000-fold signal enhancement for 129 Xe hyperpolarization in SEOP compare to the reference thermally enhanced 13 C NMR signal is also seen in experimental NMR data. Both data have been collected in identical Larmor frequency and other experimental conditions and same radio frequency during NMR data collection.

(Figure 11) Longitudinal spin relaxation time (T 1 ) is very sensitive with an increase of magnetic field and hence enhance the NMR signals is noticeable in SEOP in case of 129 Xe. As T 1 is higher for blue marking conditioning NMR experiment shows more enhanced peak compare to other.

For hyperpolarized 129 Xe in tedlar bags, the T 1 is 38±12 minutes when data collected in presence of 1.5 mT magnetic field. However, satisfactory increment in T 1 delay time (354±24 minutes) when data was collected in presence of 3000 mT magnetic field. 83 Kr stable isotope has spin I=9/2 and has larger Van der Waals size 2.02A 0 .

It has quadrupolar effect can be diffuse to nearby environment shortly & distinctively (polar to nonpolar media in vivo system). Chemical composition of materials can influence the longitudinal relaxation of hyperpolarized 83 Kr. The relaxation can distinguish among the hydrophobic and hydrophilic substrate.

Although 3 He and 129 Xe have spin half but they are not quadrupolar active. However, the 21 Ne (I=3/2), 83 Kr(I=9/2) and 131 Xe (I=3/2) have Quadrupolar moment. 34 Quadrupolar interactions make these isotopes having spin relaxation.

Due to this spin relaxation and evolution, these isotopes can be used as contrasting agents to say about the probe can determine the structural feature and chemical compositions of the surfaces for a permeable media. SEOP can calculate the relaxation of spin T 1 by using the equation nonlinear least-squares fitting for 83 Kr signal as a function of time as well as experimental number of media flip angle (≈12°) for NMR experimenting radio frequency pulses.

Hyperpolarized 83 Kr is being separated from 87 Rb gases after spin exchanging in the optical pumping process and then used in variety of in vivo system to get MRI signal. This is the first isotope showed lots of applicability for MRI technique even though has the spin is .

During experiment of canine lung tissue, the using magnet was 9.4 T, media was porous and similar porosity to alveolar dimensions which is disseminated at atmospheric pressure. Spin lattice relaxation was reasonably long enough so it is applicable in vivo system although the oxygen level could be 20%.

As 83 Kr contrasting agent is promising to develop pristine in vivo MRI methodology to identify the lung diseases epically those effect have been caused in parenchyma surface due to the surfactant concentration. Boyed the boundary this particular contrasting agent can work to figure out the size of pour of porous media in materials science.

In addition, this technique can take us about to prepare the surface coating, spatial fluctuations of surfaces. Eventually, never ending the good sign of this contrasting agent like natural abundance (11.5% of 83 Kr) makes it easy to get with reasonable price $5/L.

Metastability exchange optical pumping

3 He can also be hyperpolarized using metastability exchange optical pumping (MEOP). This process is able to polarize 3 He nuclei in the ground state with optically pumped 3 He nuclei in the metastable state. MEOP only involves 3 He nuclei at room temperature and at low pressure (≈a few mbars). The process of MEOP is very efficient (high polarization rate), however, compression of the gas up to atmospheric pressure is needed.

Dynamic nuclear polarization

Compounds containing NMR-sensitive nuclei, such as 1 H, 13 C or 15 N, can be hyperpolarized using Dynamic nuclear polarization (DNP). DNP is typically performed at low temperature (≈1 K) and high magnetic field (≈3 T). The compound is subsequently thawed and dissolved to yield a room temperature solution containing hyperpolarized nuclei.

This liquid can be used in in vivo metabolic imaging for oncology and other applications. The 13 C polarization levels in solid compounds can reach up to ≈64% and the losses during dissolution and transfer of the sample for NMR measurements can be minimized to a few percent.

Compounds containing NMR-active nuclei can also be hyperpolarized using chemical reactions with para-hydrogen, see Para-Hydrogen Induced Polarization (PHIP).

Parahydrogen induced polarization

Molecular hydrogen, H 2 , contains two different spin isomers, para-hydrogen and ortho-hydrogen, with a ratio of 25:75 at room temperature. Creating para-hydrogen induced polarization (PHIP) means that this ratio is increased, in other words that para-hydrogen is enriched.

This can be accomplished by cooling hydrogen gas and then inducing ortho-to-para conversion via an iron-oxide or charcoal catalyst. When performing this procedure at ≈70 K (i.e. with liquid nitrogen), para-hydrogen is enriched from 25% to ca. 50%. When cooling to below 20 K and then inducing the ortho-to-para conversion, close to 100% parahydrogen can be obtained.

For practical applications, the PHIP is most commonly transferred to organic molecules by reacting the hyperpolarized hydrogen with precursor molecules in the presence of a transition metal catalyst. Proton NMR signals with ca. 10,000-fold increased intensity can be obtained compared to NMR signals of the same organic molecule without PHIP and thus only "thermal" polarization at room temperature.

Signal amplification by reversible exchange (SABRE)

Signal amplification by reversible exchange (SABRE) is a technique to hyperpolarize samples without chemically modifying them. Compared to orthohydrogen or organic molecules, a much greater fraction of the hydrogen nuclei in parahydrogen align with an applied magnetic field.

In SABRE, a metal center reversibly binds to both the test molecule and a parahydrogen molecule facilitating the target molecule to pick up the polarization of the parahydrogen. This technique can be improved and utilized for a wide range of organic molecules by using an intermediate "relay" molecule like ammonia.

The ammonia efficiently binds to the metal center and picks up the polarization from the parahydrogen. The ammonia then transfers it other molecules that don't bind as well to the metal catalyst. This enhanced NMR signal allows the rapid analysis of very small amounts of material.

See also

Dynamic nuclear polarization Electron paramagnetic resonance Hyperpolarized carbon-13 MRI

Europhysics - "Take a breath of polarized noble gas" University of Virginia - "Hyperpolarized Gas MR Imaging" Swiss DNP Initiative - "DNP-NMR 13 C Hyperpolarization"

Text derived from https://en.wikipedia.org/w/index.php?oldid=1317715285 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

1 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.