Impedance matching
(Z S ) and load (Z L ) impedance in a circuit|alt=Schematic diagram of a voltage source driving a load through a source impedance In electrical engineering, impedance matching is the practice of designing or adjusting the input impedance…
≈ 18 min read
Impedance matching. encyclopegia.org, snapshot enwiki-001378431162. /a/impedance-matching
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
(Z S ) and load (Z L ) impedance in a circuit|alt=Schematic diagram of a voltage source driving a load through a source impedance In electrical engineering, impedance matching is the practice of designing or adjusting the input impedance or output impedance of an electrical device for a desired value. Often, the desired value is selected to maximize power transfer or minimize signal reflection.
For example, impedance matching is typically used to improve power transfer from a radio transmitter via the interconnecting transmission line to the antenna. Signals on a transmission line will be transmitted without reflections if the transmission line is terminated with a matching impedance.
Techniques of impedance matching include transformers, adjustable networks of lumped resistance, capacitance and inductance, or properly proportioned transmission lines. Practical impedance-matching devices will generally provide best results over a specified frequency band.
The concept of impedance matching is widespread in electrical engineering, but is relevant in other applications in which a form of energy, not necessarily electrical, is transferred between a source and a load, such as in acoustics or optics.
Theory
Impedance characterizes the ratio of energy components in a given domain. For constant signals, this impedance can also be constant. For varying signals, it usually changes with frequency.
The energy involved can be electrical, mechanical, acoustic, magnetic, electromagnetic, or thermal. The concept of electrical impedance is perhaps the most commonly known. Electrical impedance, like electrical resistance, is measured in ohms.
In general, impedance (symbol: Z) has a complex value; this means that loads generally have a resistance component (symbol: R) which forms the real part and a reactance component (symbol: X) which forms the imaginary part. This impedance characterizes the ratio between the voltage and current components in the medium.
In simple cases (such as low-frequency or direct current power transmission) the reactance may be negligible or zero; the impedance can be considered a pure resistance, expressed as a real number. In the following summary, we will consider the general case when resistance and reactance are both significant, and the special case in which the reactance is negligible.
Maximum power transfer matching
Complex conjugate matching is used when maximum power transfer is required, namely Z_\text{load} = Z_\text{source}^*, where a superscript * indicates the complex conjugate. A conjugate match is different from a reflection-less match when either the source or load has a reactive component.
If the source has a reactive component, but the load is purely resistive, then matching can be achieved by adding a reactance of the same magnitude but opposite sign to the load. This simple matching network, consisting of a single element, will usually achieve a perfect match at only a single frequency.
This is because the added element will either be a capacitor or an inductor, whose impedance in both cases is frequency dependent, and will not, in general, follow the frequency dependence of the source impedance. For wide bandwidth applications, a more complex network must be designed.
If a lossless reciprocal two-port network matches a load impedance Z_L = R_L + jX_L to a source impedance Z_S = R_S + jX_S with transmission phase shift \varphi (i.e., \{Z_S \xrightarrow{\varphi} Z_L\} ), then the transmission matrix of the matching network can be expressed as \begin{bmatrix} A & B \\ C & D \end{bmatrix} = \begin{bmatrix} a & jb \\ jc & d \end{bmatrix} = \frac{1}{\sqrt{R_S R_L}} \begin{bmatrix} \Re(\bar{Z_S}e^{j\varphi}) & j\Im(\bar{Z_S}\bar{Z_L}e^{j\varphi}) \\ j\Im(e^{j\varphi}) & \Re(\bar{Z_L}e^{j\varphi}) \end{bmatrix}, where \Re(Z) and \Im(Z) are real and imaginary part of complex number Z . \bar{Z} is the complex conjugate of Z . If a lossless reciprocal two-port network matches a resistive load impedance Z_L = R_L to a resistive source impedance Z_S = R_S with a transmission phase shift of \varphi (i.e., \{R_S \xrightarrow{\varphi} R_L\} ), then the transmission matrix (ABCD matrix) of the matching network can be expressed as \begin{bmatrix} a & jb \\ jc & d \end{bmatrix} = \begin{bmatrix} \sqrt{\frac{R_S}{R_L}}\cos\varphi & j\sqrt{{R_S}{R_L}}\sin{\varphi} \\ j\frac{1}{\sqrt{R_SR_L}}\sin\varphi & \sqrt{\frac{R_L}{R_S}}\cos\varphi \end{bmatrix}. If both source and load are equal resistive impedance (i.e., R_S = R_L = R_0 ), then the ABCD parameters can be written as \begin{bmatrix} a & jb \\ jc & d \end{bmatrix} = \begin{bmatrix} \cos\varphi & jR_0\sin{\varphi} \\ j\frac{1}{R_0}\sin\varphi & \cos\varphi \end{bmatrix}, which is a transmission line with characteristic impedance R_0 and electrical length \theta = \beta l = \varphi.
Impedance-matching devices
Adjusting the source impedance or the load impedance, in general, is called "impedance matching". There are three ways to improve an impedance mismatch, all of which are called "impedance matching": Devices intended to present an apparent load to the source of Z load = Z source * (complex conjugate matching).
Given a source with a fixed voltage and fixed source impedance, the maximum power theorem says this is the only way to extract the maximum power from the source. Devices intended to present an apparent load of Z load = Z line (complex impedance matching), to avoid echoes.
Given a transmission line source with a fixed source impedance, this "reflectionless impedance matching" at the end of the transmission line is the only way to avoid reflecting echoes back to the transmission line. Devices intended to present an apparent source resistance as close to zero as possible, or presenting an apparent source voltage as high as possible.
This is the only way to maximize energy efficiency, and so it is used at the beginning of electrical power lines. Such an impedance bridging connection also minimizes distortion and electromagnetic interference; it is also used in modern audio amplifiers and signal-processing devices.
There are a variety of devices used between a source of energy and a load that perform "impedance matching". To match electrical impedances, engineers use combinations of transformers, resistors, inductors, capacitors and transmission lines.
These passive (and active) impedance-matching devices are optimized for different applications and include baluns, antenna tuners (sometimes called ATUs or roller-coasters, because of their appearance), acoustic horns, matching networks, and terminators.
Transformers
Transformers are sometimes used to match the impedances of circuits. A transformer converts alternating current at one voltage to the same waveform at another voltage. The power input to the transformer and output from the transformer is the same (except for conversion losses).
The side with the lower voltage is at low impedance (because this has the lower number of turns), and the side with the higher voltage is at a higher impedance (as it has more turns in its coil). One example of this method involves a television balun transformer.
This transformer allows interfacing a balanced line (300-ohm twin-lead) and an unbalanced line (75-ohm coaxial cable such as RG-6). To match the impedances, both cables must be connected to a matching transformer with a turns ratio of 2:1.
In this example, the 300-ohm line is connected to the transformer side with more turns; the 75-ohm cable is connected to the transformer side with fewer turns. The formula for calculating the transformer turns ratio for this example is: \text{turns ratio} = \sqrt{\frac{\text{source resistance}}{\text{load resistance}}}
Resistive network
Resistive impedance matches are easiest to design and can be achieved with a simple L pad consisting of two resistors. Power loss is an unavoidable consequence of using resistive networks, and they are only (usually) used to transfer line level signals.
Stepped transmission line
Most lumped-element devices can match a specific range of load impedances. For example, in order to match an inductive load into a real impedance, a capacitor needs to be used. If the load impedance becomes capacitive, the matching element must be replaced by an inductor.
In many cases, there is a need to use the same circuit to match a broad range of load impedance and thus simplify the circuit design. This issue was addressed by the stepped transmission line, where multiple, serially placed, quarter-wave dielectric slugs are used to vary a transmission line's characteristic impedance.
By controlling the position of each element, a broad range of load impedances can be matched without having to reconnect the circuit.
Filters
Filters are frequently used to achieve impedance matching in telecommunications and radio engineering. In general, it is not theoretically possible to achieve perfect impedance matching at all frequencies with a network of discrete components. Impedance matching networks are designed with a definite bandwidth, take the form of a filter, and use filter theory in their design.
Applications requiring only a narrow bandwidth, such as radio tuners and transmitters, might use a simple tuned filter such as a stub. This would provide a perfect match at one specific frequency only. Wide bandwidth matching requires filters with multiple sections.
L-section
(i.e. if network (a) can be used; otherwise network (b) can be used. A simple electrical impedance-matching network requires one capacitor and one inductor. In the figure to the right, R 1 > R 2 , however, either R 1 or R 2 may be the source and the other the load.
One of X 1 or X 2 must be an inductor and the other must be a capacitor. One reactance is in parallel with the source (or load), and the other is in series with the load (or source). If a reactance is in parallel with the source, the effective network matches from high to low impedance.
The analysis is as follows. Consider a real source impedance of R_1 and real load impedance of R_2 .
If a reactance X_1 is in parallel with the source impedance, the combined impedance can be written as: \frac{j R_1 X_1}{R_1 + j X_1} If the imaginary part of the above impedance is canceled by the series reactance, the real part is R_2 = \frac{R_1 X_1^2}{R_1^2 + X_1^2} Solving for X_1 \left\vert X_1 \right\vert = \frac{R_1 }{Q} . \left\vert X_2 \right\vert = Q R_2 . where Q = \sqrt{\frac{R_1 - R_2}{ R_2 }} . Note, X_1 , the reactance in parallel, has a negative reactance because it is typically a capacitor.
This gives the L-network the additional feature of harmonic suppression since it is a low-pass filter too. The inverse connection (impedance step-up) is simply the reverse—for example, reactance in series with the source. The magnitude of the impedance ratio is limited by reactance losses such as the Q of the inductor.
Multiple L-sections can be wired in cascade to achieve higher impedance ratios or greater bandwidth. Transmission line matching networks can be modeled as infinitely many L-sections wired in cascade. Optimal matching circuits can be designed for a particular system using Smith charts.
Power factor correction
Power factor correction devices are intended to cancel the reactive and nonlinear characteristics of a load at the end of a power line. This causes the load seen by the power line to be purely resistive. For a given true power required by a load this minimizes the true current supplied through the power lines, and minimizes power wasted in the resistance of those power lines.
For example, a maximum power point tracker is used to extract the maximum power from a solar panel and efficiently transfer it to batteries, the power grid or other loads. The maximum power theorem applies to its "upstream" connection to the solar panel, so it emulates a load resistance equal to the solar panel source resistance.
However, the maximum power theorem does not apply to its "downstream" connection. That connection is an impedance bridging connection; it emulates a high-voltage, low-resistance source to maximize efficiency. On the power grid the overall load is usually inductive.
Consequently, power factor correction is most commonly achieved with banks of capacitors. It is only necessary for correction to be achieved at one single frequency, the frequency of the supply.
Complex networks are only required when a band of frequencies must be matched and this is the reason why simple capacitors are all that is usually required for power factor correction. \Gamma_{12} = {Z_2 - Z_1 \over Z_2 + Z_1} while the voltage reflection coefficient for a wave moving from medium 2 to medium 1 is \Gamma_{21} = {Z_1 - Z_2 \over Z_1 + Z_2} \Gamma_{21} = -\Gamma_{12} \, so the reflection coefficient is the same (except for sign), no matter from which direction the wave approaches the boundary. There is also a current reflection coefficient, which is the negative of the voltage reflection coefficient.
If the wave encounters an open at the load end, positive voltage and negative current pulses are transmitted back toward the source (negative current means the current is going the opposite direction). Thus, at each boundary there are four reflection coefficients (voltage and current on one side, and voltage and current on the other side).
All four are the same, except that two are positive and two are negative. The voltage reflection coefficient and current reflection coefficient on the same side have opposite signs. Voltage reflection coefficients on opposite sides of the boundary have opposite signs.
Because they are all the same except for sign, it is traditional to interpret the reflection coefficient as the voltage reflection coefficient (unless otherwise indicated). Either end (or both ends) of a transmission line can be a source or a load (or both), so there is no inherent preference for which side of the boundary is medium 1 and which side is medium 2.
With a single transmission line, it is customary to define the voltage reflection coefficient for a wave incident on the boundary from the transmission line side, regardless of whether a source or load is connected on the other side.
Load-end conditions
In a transmission line, a wave travels from the source along the line. Suppose the wave hits a boundary (an abrupt change in impedance). Some of the wave is reflected back, while some keeps moving onwards.
(Assume there is only one boundary, at the load.) Let V_i \, and I_i \, be the voltage and current that is incident on the boundary from the source side. V_t \, and I_t \, be the voltage and current that is transmitted to the load.
V_r \, and I_r \, be the voltage and current that is reflected back toward the source. On the line side of the boundary V_i = Z_c I_i \, and V_r = -Z_c I_r \, and on the load side V_t = Z_L I_t \, where V_i \, , V_r \, , V_t \, , I_i \, , I_r \, , and I_t \, are phasors.
At a boundary, voltage and current must be continuous; therefore V_t = V_i + V_r \, I_t = I_i + I_r \, All these conditions are satisfied by V_r = \Gamma_{TL} V_i \, I_r = - \Gamma_{TL} I_i \, V_t = (1 + \Gamma_{TL} ) V_i \, I_t = ( 1 - \Gamma_{TL} ) I_i \, where \Gamma_{TL} \, is the reflection coefficient going from the transmission line to the load. \Gamma_{TL} = {Z_L - Z_c \over Z_L + Z_c} = \Gamma_L \,
Source-end conditions
At the source end of the transmission line, there may be waves incident both from the source and from the line; a reflection coefficient for each direction may be computed with - \Gamma_{ST} = \Gamma_{TS} = {Z_s - Z_c \over Z_s + Z_c} = \Gamma_S \, , where Zs is the source impedance. The source of waves incident from the line is the reflections from the load end.
If the source impedance matches the line, reflections from the load end will be absorbed at the source end. If the transmission line is not matched at both ends reflections from the load will be re-reflected at the source and re-re-reflected at the load end ad infinitum, losing energy on each transit of the transmission line.
This can cause a resonance condition and strongly frequency-dependent behavior. In a narrow-band system this can be desirable for matching, but is generally undesirable in a wide-band system.
Source-end impedance
Z_{in} = Z_c \frac { (1 + T^2 \Gamma_L ) } {( 1 - T^2 \Gamma_L )} \, where T \ , is the one-way transfer function (from either end to the other) when the transmission line is exactly matched at source and load. T \, accounts for everything that happens to the signal in transit (including delay, attenuation and dispersion). If there is a perfect match at the load, \Gamma_L = 0 \, and Z_{in} = Z_c \,
Transfer function
V_L = V_S \frac {T (1 - \Gamma_S)(1 + \Gamma_L)} { 2 ( 1 -T^2 \Gamma_S \Gamma_L) } \, where V_S \, is the open circuit (or unloaded) output voltage from the source. Note that if there is a perfect match at both ends \Gamma_L = 0 \, and \Gamma_S = 0 \, and then V_L = V_S \frac {T} {2}\, .
Telephone systems
Telephone systems also use matched impedances to minimise echo on long-distance lines. This is related to transmission-line theory. Matching also enables the telephone hybrid coil (2- to 4-wire conversion) to operate correctly.
As the signals are sent and received on the same two-wire circuit to the central office (or exchange), cancellation is necessary at the telephone earpiece so excessive sidetone is not heard. All devices used in telephone signal paths are generally dependent on matched cable, source and load impedances. In the local loop, the impedance chosen is 600 ohms (nominal).
Terminating networks are installed at the exchange to offer the best match to their subscriber lines. Each country has its own standard for these networks, but they are all designed to approximate about 600 ohms over the voice frequency band.
Loudspeaker amplifiers
Audio amplifiers typically do not match impedances, but provide an output impedance that is lower than the load impedance (such as r = {Z_2 - Z_1 \over Z_1 + Z_2} to calculate reflection and transmission coefficients for the interface. For non-magnetic dielectrics, this equation is equivalent to the Fresnel equations. Unwanted reflections can be reduced by the use of an anti-reflection optical coating.
Mechanics
If a body of mass m collides elastically with a second body, maximum energy transfer to the second body will occur when the second body has the same mass m. In a head-on collision of equal masses, the energy of the first body will be completely transferred to the second body (as in Newton's cradle, for example). In this case, the masses act as "mechanical impedances", which must be matched to maximize energy transfer.
If m_1 and m_2 are the masses of the moving and stationary bodies, and P is the momentum of the system (which remains constant throughout the collision), the energy of the second body after the collision will be E 2 : E_2=\frac{2P^2m_2}{(m_1+m_2)^2} which is analogous to the power-transfer equation. If we cannot change the masses of bodies, then we can match their impedance with a lever.
Imagine a large ball dropping to the ground, and a small ball lying on the ground. The large ball hits the short end of a lever, and the small ball is launched from the long end of the lever. If the lever arm lengths satisfy l_1 m_1 = l_2 m_2 , then all energy would be transferred to the small ball if collisions are elastic.
This is roughly how the middle ear works (see above). These principles are useful in the application of highly energetic materials (explosives). If an explosive charge is placed on a target, the sudden release of energy causes compression waves to propagate through the target radially from the point-charge contact.
When the compression waves reach areas of high acoustic impedance mismatch (such as the opposite side of the target), tension waves reflect back and create spalling. The greater the mismatch, the greater the effect of creasing and spalling will be.
A charge initiated against a wall with air behind it will do more damage to the wall than a charge initiated against a wall with soil behind it.