Lead–lag compensator

A lead–lag compensator is a component in a control system that improves an undesirable frequency response in a feedback and control system.

Uses your system voice; voice and rate in settings.

Snapshot

≈ 4 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

A lead–lag compensator is a component in a control system that improves an undesirable frequency response in a feedback and control system. It is a fundamental building block in classical control theory. \frac{Y}{X} = \frac{s-z}{s-p} where X is the input to the compensator, Y is the output, s is the complex Laplace transform variable, z is the zero frequency and p is the pole frequency.

The pole and zero are both typically negative, or left of the origin in the complex plane. In a lead compensator, |z| , while in a lag compensator |z| > |p| . A lead-lag compensator consists of a lead compensator cascaded with a lag compensator.

The overall transfer function can be written as \frac{Y}{X} = \frac{(s-z_1)(s-z_2)}{(s-p_1)(s-p_2)}. Typically |p_1| > |z_1| > |z_2| > |p_2| , where z 1 and p 1 are the zero and pole of the lead compensator and z 2 and p 2 are the zero and pole of the lag compensator. The lead compensator provides phase lead at high frequencies.

This shifts the root locus to the left, which enhances the responsiveness and stability of the system. The lag compensator provides phase lag at low frequencies which reduces the steady state error. The precise locations of the poles and zeros depend on both the desired characteristics of the closed loop response and the characteristics of the system being controlled.

However, the pole and zero of the lag compensator should be close together so as not to cause the poles to shift right, which could cause instability or slow convergence. Since their purpose is to affect the low frequency behaviour, they should be near the origin. Y = X - (z_1 + z_2) \frac{X}{s} + z_1 z_2 \frac{X}{s^2}+ (p_1+p_2)\frac{Y}{s} - p_1 p_2 \frac{Y}{s^2}.

In analog control systems, where integrators are expensive, it is common to group terms together to minimize the number of integrators required: Y = X + \frac{1}{s}\left((p_1+p_2)Y - (z_1+z_2)X + \frac{1}{s}(z_1 z_2 X - p_1 p_2 Y)\right). In analog control, the control signal is typically an electrical voltage or current (although other signals such as hydraulic pressure can be used).

In this case a lead-lag compensator will consist of a network of operational amplifiers ("op-amps") connected as integrators and weighted adders. A possible physical realization of a lead-lag compensator is shown below (note that the op-amp is used to isolate the networks): In digital control, the operations are performed numerically by discretization of the derivatives and integrals.

The reason for expressing the transfer function as an integral equation is that differentiating signals amplify the noise on the signal, since even very small amplitude noise has a high derivative if its frequency is high, while integrating a signal averages out the noise. This makes implementations in terms of integrators the most numerically stable.

F(x) = A(x) + i B(x) , where A(x) is the real part and B(x) is the imaginary part of the single-variable function, F(x) . The phase angle of the network is the argument of F(x) ; in the left half plane this is \arctan\!\bigl(B(x)/A(x)\bigr) . If the phase angle is negative for all signal frequencies in the network then the network is classified as a lag network.

If the phase angle is positive for all signal frequencies in the network then the network is classified as a lead network. If the total network phase angle has a combination of positive and negative phase as a function of frequency then it is a lead-lag network.

Depending upon the nominal operation design parameters of a system under an active feedback control, a lag or lead network can cause instability and poor speed and response times.

See also

Compensator (control theory) Control engineering Control theory Damping ratio Fall time PID controller Proportional control Response time compensation Rise time Settling time Steady state Step response Systems theory Time constant Transient modelling Transient response Transient state Transition time

References

Nise, Norman S. (2004); Control Systems Engineering (4 ed.); Wiley & Sons; Horowitz, P. & Hill, W. (2001); The Art of Electronics (2 ed.); Cambridge University Press; Cathey, J.J. (1988); Electronic Devices and Circuits (Schaum's Outlines Series); McGraw-Hill

Matlab Control Tutorials: lead and lag compensators lead controller using Matlab Lead-Lag Frequency Response at MathPages Lead-Lag Algorithms at MathPages

Text derived from https://en.wikipedia.org/w/index.php?oldid=1358744397 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

No external citation was extracted for this revision. That is a statement about the source, not a claim that none exists.