Left axis deviation
≈ 3 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
is a diagram that is used to determine the heart's electrical axis in the frontal plane. In electrocardiography, left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°. This is reflected by a QRS complex positive in lead I and negative in leads aVF and II. There are several potential causes of LAD. Some of the causes include normal variation, thickened left ventricle, conduction defects, inferior wall myocardial infarction, pre-excitation syndrome, ventricular ectopic rhythms, congenital heart disease, high potassium levels, emphysema, mechanical shift, and paced rhythm. Symptoms and treatment of left axis deviation depend on the underlying cause.
is a diagram that is used to determine the heart's electrical axis in the frontal plane.]] In electrocardiography, left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°. This is reflected by a QRS complex positive in lead I and negative in leads aVF and II. There are several potential causes of LAD. Some of the causes include normal variation, thickened left ventricle, conduction defects, inferior wall myocardial infarction, pre-excitation syndrome, ventricular ectopic rhythms, congenital heart disease, high potassium levels, emphysema, mechanical shift, and paced rhythm. Symptoms and treatment of left axis deviation depend on the underlying cause. Determining the electrical axis can provide insight into underlying disease states and help steer the differential diagnosis. There are several methods to determining the ECG axis. The easiest method is the quadrant method, where one looks at lead I and lead aVF. First, examine the QRS complex in both leads I and avF and determine if the QRS complex is positive (height of R wave > S wave), equiphasic (R wave = S wave), or negative (R wave < S wave). If lead I is positive and lead aVF is negative, then this is a possible LAD. To determine a true LAD, examine QRS in lead II. If the QRS complex is positive in lead II, then this is a normal axis. On the other hand, if QRS complex is negative in lead II, then this is a LAD. Another method of determining LAD is called the Isoelectric lead, which allows for a more precise estimation of the QRS axis. ==See also== Right axis deviation ==References==
Text derived from https://en.wikipedia.org/w/index.php?oldid=1305983852 under CC BY-SA 4.0; modifications have been made.