Liquid junction interface
In mass spectrometry, liquid junction interface is an ion source or set-up that couples peripheric devices, such as capillary electrophoresis, to mass spectrometry. See the IUPAC recommendation definition as a means of coupling capillary electrophoresis to mass spectrometry in which a liquid reservoir surrounds the separation capillary and transfer capillary to the mass spectrometer. The reservoir provides electrical contact for the capillary electrophoresis. The term liquid junction interface has also been used by Henry M. Fales and coworkers for ion sources where the analyte is in direct contact with the high voltage supply. This includes in particular nanospray ion sources where a wire made of stainless steel, gold or other conducting material makes contact with the sample solution inside uncoated spray capillaries. The principle is also applied when a stainless steel union connects a chromatography outlet to a spray capillary. Its use has a number of advantages with respect to simplification of interface or source design, easy handling and cost. Electrolysis effects have to be controlled. Liquid junction interfaces have been used for on-line desalting in conjunction with mass spectrometry. Thereby, chromatographic material such as C18 phase was directly placed in the flow path coming from a pump or an HPLC device.…
Article summary
In mass spectrometry, liquid junction interface is an ion source or set-up that couples peripheric devices, such as capillary electrophoresis, to mass spectrometry. See the IUPAC recommendation definition as a means of coupling capillary electrophoresis to mass spectrometry in which a liquid reservoir surrounds the separation capillary and transfer capillary to the mass spectrometer. The reservoir provides electrical contact for the capillary electrophoresis. The term liquid junction interface has also been used by Henry M. Fales and coworkers for ion sources where the analyte is in direct contact with the high voltage supply. This includes in particular nanospray ion sources where a wire made of stainless steel, gold or other conducting material makes contact with the sample solution inside uncoated spray capillaries. The principle is also applied when a stainless steel union connects a chromatography outlet to a spray capillary. Its use has a number of advantages with respect to simplification of interface or source design, easy handling and cost. Electrolysis effects have to be controlled. Liquid junction interfaces have been used for on-line desalting in conjunction with mass spectrometry. Thereby, chromatographic material such as C18 phase was directly placed in the flow path coming from a pump or an HPLC device.…
Key claims
No claims recorded.
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?
Bibliography
No sources recorded.
Key claims and bibliography are generated from the same tracked claims and sources as the article page.