Lumped-element model

Uses your system voice; voice and rate in settings.

Snapshot

≈ 7 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

The lumped-element model (also called lumped-parameter model, or lumped-component model) is a simplified representation of a physical system or circuit that assumes all components are concentrated at a single point and their behavior can be described by idealized mathematical models. The lumped-element model simplifies the system or circuit behavior description into a topology. It is useful in electrical systems (including electronics), mechanical multibody systems, heat transfer, acoustics, etc. This is in contrast to distributed parameter systems or models in which the behaviour is distributed spatially and cannot be considered as localized into discrete entities. The simplification reduces the state space of the system to a finite dimension, and the partial differential equations (PDEs) of the continuous (infinite-dimensional) time and space model of the physical system into ordinary differential equations (ODEs) with a finite number of parameters.

The lumped-element model (also called lumped-parameter model, or lumped-component model) is a simplified representation of a physical system or circuit that assumes all components are concentrated at a single point and their behavior can be described by idealized mathematical models. The lumped-element model simplifies the system or circuit behavior description into a topology. It is useful in electrical systems (including electronics), mechanical multibody systems, heat transfer, acoustics, etc. This is in contrast to distributed parameter systems or models in which the behaviour is distributed spatially and cannot be considered as localized into discrete entities. The simplification reduces the state space of the system to a finite dimension, and the partial differential equations (PDEs) of the continuous (infinite-dimensional) time and space model of the physical system into ordinary differential equations (ODEs) with a finite number of parameters. The change of the magnetic flux in time outside a conductor is zero. \frac{\partial \Phi_B} {\partial t} = 0 The change of the charge in time inside conducting elements is zero. \frac{\partial q} {\partial t} = 0 Signal timescales of interest are much larger than propagation delay of electromagnetic waves across the lumped element. The first two assumptions result in Kirchhoff's circuit laws when applied to Maxwell's equations and are only applicable when the circuit is in steady state. The third assumption is the basis of the lumped-element model used in network analysis. Less severe assumptions result in the distributed-element model, while still not requiring the direct application of the full Maxwell equations. \dot{Q}=\frac{T_i-T_o}{R_i+R_1+R_2+R_o}=\frac{T_i-T_1}{R_i}=\frac{T_i-T_2}{R_i+R_1}=\frac{T_i-T_3}{R_i+R_1+R_2}=\frac{T_1-T_2}{R_1}=\frac{T_3-T_o}{R_0} where R_i=\frac{1}{h_iA} , R_o=\frac{1}{h_oA} , R_1=\frac{L_1}{k_1A} , and R_2=\frac{L_2}{k_2A} \text {Rate of cooling} \sim \Delta T An object at a different temperature from its surroundings will ultimately come to a common temperature with its surroundings. A relatively hot object cools as it warms its surroundings; a cool object is warmed by its surroundings. When considering how quickly (or slowly) something cools, we speak of its rate of cooling – how many degrees' change in temperature per unit of time. The rate of cooling of an object depends on how much hotter the object is than its surroundings. The temperature change per minute of a hot apple pie will be more if the pie is put in a cold freezer than if it is placed on the kitchen table. When the pie cools in the freezer, the temperature difference between it and its surroundings is greater. On a cold day, a warm home will leak heat to the outside at a greater rate when there is a large difference between the inside and outside temperatures. Keeping the inside of a home at high temperature on a cold day is thus more costly than keeping it at a lower temperature. If the temperature difference is kept small, the rate of cooling will be correspondingly low. As Newton's law of cooling states, the rate of cooling of an object – whether by conduction, convection, or radiation – is approximately proportional to the temperature difference ΔT. Frozen food will warm up faster in a warm room than in a cold room. Note that the rate of cooling experienced on a cold day can be increased by the added convection effect of the wind. This is referred to as wind chill. For example, a wind chill of -20 °C means that heat is being lost at the same rate as if the temperature were -20 °C without wind. \frac{d Q}{d t} = - h \cdot A(T(t)- T_{\text{env}}) = - h \cdot A \Delta T(t) where Q is thermal energy in joules h is the heat transfer coefficient between the surface and the fluid A is the surface area of the heat being transferred T is the temperature of the object's surface and interior (since these are the same in this approximation) T env is the temperature of the environment ΔT(t) = T(t) − T env is the time-dependent thermal gradient between environment and object Putting heat transfers into this form is sometimes not a very good approximation, depending on ratios of heat conductances in the system. If the differences are not large, an accurate formulation of heat transfers in the system may require analysis of heat flow based on the (transient) heat transfer equation in nonhomogeneous or poorly conductive media. If the entire body is treated as lumped-capacitance heat reservoir, with total heat content which is proportional to simple total heat capacity C , and T , the temperature of the body, or Q = C T . It is expected that the system will experience exponential decay with time in the temperature of a body. From the definition of heat capacity C comes the relation C = dQ/dT . Differentiating this equation with regard to time gives the identity (valid so long as temperatures in the object are uniform at any given time): dQ/dt = C (dT/dt) . This expression may be used to replace dQ/dt in the first equation which begins this section, above. Then, if T(t) is the temperature of such a body at time t , and T_\text{env} is the temperature of the environment around the body: \frac{d T(t)}{d t} = - r (T(t) - T_{\text{env}}) = - r \Delta T(t) where r = hA/C is a positive constant characteristic of the system, which must be in units of s^{-1} , and is therefore sometimes expressed in terms of a characteristic time constant t_0 given by: t_0 = 1/r = -\Delta T(t)/(dT(t)/dt) . Thus, in thermal systems, t_0 = C/hA . (The total heat capacity C of a system may be further represented by its mass-specific heat capacity c_p multiplied by its mass m , so that the time constant t_0 is also given by mc_p/hA ). The solution of this differential equation, by standard methods of integration and substitution of boundary conditions, gives: T(t) = T_{\mathrm{env}} + (T(0) - T_{\mathrm{env}}) \ e^{-r t}. If: \Delta T(t) \quad is defined as : T(t) - T_{\mathrm{env}} \ , \quad where \Delta T(0)\quad is the initial temperature difference at time 0, then the Newtonian solution is written as: \Delta T(t) = \Delta T(0) \ e^{-r t} = \Delta T(0) \ e^{-t/t_0}. This same solution is almost immediately apparent if the initial differential equation is written in terms of \Delta T(t) , as the single function to be solved for. \frac{d T(t)}{d t} = \frac{d \Delta T(t)}{d t} = - \frac{1}{t_0} \Delta T(t)

Text derived from https://en.wikipedia.org/w/index.php?oldid=1298726519 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

2 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.