Microcrystal electron diffraction
≈ 5 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
Microcrystal electron diffraction, or MicroED, is a CryoEM method that was developed by the Gonen laboratory in late 2013 at the Janelia Research Campus of the Howard Hughes Medical Institute. MicroED is a form of electron crystallography where thin 3D crystals are used for structure determination by electron diffraction. Prior to this demonstration, macromolecular (protein) electron crystallography was mainly used on 2D crystals, for example. The method is one of several modern versions of approaches to determine atomic structures using electron diffraction first demonstrated for the positions of hydrogen atoms in NH4Cl crystals by W. E. Laschkarew and I. D. Usykin in 1933, which has since been used for surfaces, via precession electron diffraction, with much of the early work described in the work of Boris Vainshtein and Douglas L. Dorset. The method was developed for structure determination of proteins from nanocrystals that are typically not suitable for X-ray diffraction because of their size. Crystals that are one billionth the size needed for X-ray crystallography can yield high quality data. The samples are frozen hydrated as for all other CryoEM modalities but instead of using the transmission electron microscope (TEM) in imaging mode one uses it in diffraction mode with a low electron exposure (typically − /Å 2 /s).…
Microcrystal electron diffraction, or MicroED, is a CryoEM method that was developed by the Gonen laboratory in late 2013 at the Janelia Research Campus of the Howard Hughes Medical Institute. MicroED is a form of electron crystallography where thin 3D crystals are used for structure determination by electron diffraction. Prior to this demonstration, macromolecular (protein) electron crystallography was mainly used on 2D crystals, for example. The method is one of several modern versions of approaches to determine atomic structures using electron diffraction first demonstrated for the positions of hydrogen atoms in NH4Cl crystals by W. E. Laschkarew and I. D. Usykin in 1933, which has since been used for surfaces, via precession electron diffraction, with much of the early work described in the work of Boris Vainshtein and Douglas L. Dorset. The method was developed for structure determination of proteins from nanocrystals that are typically not suitable for X-ray diffraction because of their size. Crystals that are one billionth the size needed for X-ray crystallography can yield high quality data. The samples are frozen hydrated as for all other CryoEM modalities but instead of using the transmission electron microscope (TEM) in imaging mode one uses it in diffraction mode with a low electron exposure (typically − /Å 2 /s). The nano crystal is exposed to the diffracting beam and continuously rotated while diffraction is collected on a fast camera as a movie. MicroED data is then processed using software for X-ray crystallography for structure analysis and refinement. The hardware and software used in a MicroED experiment are standard and broadly available.
Experimental setup
Detailed protocols for setting up the electron microscope and for data collections have been published.
Still diffraction
The initial proof of concept publication on MicroED used lysozyme crystals. Up to 90 degrees of data were collected from a single nano crystal, with discrete 1 degree steps between frames. Each diffraction pattern was collected with an ultra-low dose rate of ~0.01 e − /Å 2 /s. Data from 3 crystals was merged to yield a 2.9Å resolution structure with good refinement statistics, enabling determination of the structure of a dose-sensitive protein from 3D microcrystals in cryogenic conditions.
Continuous rotation
MicroED uses continuous rotation during the data collection scheme. Here the crystal is slowly rotated in a single direction while diffraction is recorded on a fast camera as a movie. This led to several improvements in data quality and allowed data processing using standard X-ray crystallographic software. Continuous rotation MicroED improves sampling of reciprocal space.
Data processing
Detailed protocols for MicroED data processing have been published. When MicroED data is collected using continuous stage rotation, standard crystallography software can be used.
Comparison with other electron diffraction methods
Other electron diffraction methods that have been developed and demonstrated to work include Automated Diffraction Tomography (ADT) and Rotation Electron Diffraction (RED ). These methods differ slightly from MicroED: In ADT discrete steps of goniometer tilt are used to cover reciprocal space in combination with beam precession to reduce dynamical diffraction effects. ADT uses hardware and software for precession and scanning transmission electron microscopy for crystal tracking. RED is done in TEM but the goniometer is tilted in discrete steps and beam tilting is used to fill in the gaps. Software is used to process ADT and RED data. Video interview about the development of MicroED and its applications The Janelia Archives background on MicroED Background and publications on MicroED from the Gonen Laboratory
Text derived from https://en.wikipedia.org/w/index.php?oldid=1377070678 under CC BY-SA 4.0; modifications have been made.