Lesson plan
Minimum phase
In control theory and signal processing, a linear, time-invariant system is said to be minimum-phase if the system and its inverse are causal and stable. The most general causal LTI transfer function can be uniquely factored into a series of an all-pass and a minimum phase system. The system function is then the product of the two parts, and in the time domain the response of the system is the convolution of the two part responses. The difference between a minimum-phase and a general transfer function is that a minimum-phase system has all of the poles and zeros of its transfer function in the left half of the s-plane representation (in discrete time, respectively, inside the unit circle of the z plane). Since inverting a system function leads to poles turning to zeros and conversely, and poles on the right side (s-plane imaginary line) or outside (z-plane unit circle) of the complex plane lead to unstable systems, only the class of minimum-phase systems is closed under inversion. Intuitively, the minimum-phase part of a general causal system implements its amplitude response with minimal group delay, while its all-pass part corrects its phase response alone to correspond with the original system function. The analysis in terms of poles and zeros is exact only in the case of transfer functions which can be expressed as ratios of polynomials.…
Article summary
In control theory and signal processing, a linear, time-invariant system is said to be minimum-phase if the system and its inverse are causal and stable. The most general causal LTI transfer function can be uniquely factored into a series of an all-pass and a minimum phase system. The system function is then the product of the two parts, and in the time domain the response of the system is the convolution of the two part responses. The difference between a minimum-phase and a general transfer function is that a minimum-phase system has all of the poles and zeros of its transfer function in the left half of the s-plane representation (in discrete time, respectively, inside the unit circle of the z plane). Since inverting a system function leads to poles turning to zeros and conversely, and poles on the right side (s-plane imaginary line) or outside (z-plane unit circle) of the complex plane lead to unstable systems, only the class of minimum-phase systems is closed under inversion. Intuitively, the minimum-phase part of a general causal system implements its amplitude response with minimal group delay, while its all-pass part corrects its phase response alone to correspond with the original system function. The analysis in terms of poles and zeros is exact only in the case of transfer functions which can be expressed as ratios of polynomials.…
Key claims
No claims recorded.
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?
Bibliography
No sources recorded.
Key claims and bibliography are generated from the same tracked claims and sources as the article page.