separator are visible. Multi-layer insulation (MLI) is thermal insulation composed of multiple layers of thin sheets and is often used on spacecraft and cryogenics. Also referred to as superinsulation, MLI is one of the main items of the spacecraft thermal design, primarily intended to reduce heat loss by thermal radiation. In its basic form, it does not appreciably insulate against other thermal losses such as heat conduction or convection. It is therefore commonly used on satellites and other applications in vacuum where conduction and convection are much less significant and radiation dominates. MLI gives many satellites and other space probes the appearance of being covered with gold foil which is the effect of the amber-coloured Kapton layer deposited over the silver Aluminized mylar. For non-spacecraft applications, MLI works only as part of a vacuum insulation system. For use in cryogenics, wrapped MLI can be installed inside the annulus of vacuum jacketed pipes. MLI may also be combined with advanced vacuum insulation for use in high temperature applications.

separator are visible.]] Multi-layer insulation (MLI) is thermal insulation composed of multiple layers of thin sheets and is often used on spacecraft and cryogenics. Also referred to as superinsulation, MLI is one of the main items of the spacecraft thermal design, primarily intended to reduce heat loss by thermal radiation. In its basic form, it does not appreciably insulate against other thermal losses such as heat conduction or convection. It is therefore commonly used on satellites and other applications in vacuum where conduction and convection are much less significant and radiation dominates. MLI gives many satellites and other space probes the appearance of being covered with gold foil which is the effect of the amber-coloured Kapton layer deposited over the silver Aluminized mylar. For non-spacecraft applications, MLI works only as part of a vacuum insulation system. For use in cryogenics, wrapped MLI can be installed inside the annulus of vacuum jacketed pipes. MLI may also be combined with advanced vacuum insulation for use in high temperature applications. Q = U A \Delta T. Theoretically, the heat transfer coefficient between two layers with emissivities \epsilon_1 and \epsilon_2 , at absolute temperatures T_1 and T_2 under vacuum, is U = \sigma (T_1^2+ T_2^2)(T_1+T_2)\frac{1}{1/\epsilon_1 + 1/\epsilon_2 - 1}, where \sigma=5.67\times10^{-8} Wm −2 K −4 is the Stefan-Boltzmann constant. If the temperature difference is not too large ( |\Delta T| , then a stack of N of layers, all with the same emissivity \epsilon on both sides, will have an overall heat transfer coefficient U = 4\sigma T^3 \frac{1}{(N-1)(2/\epsilon - 1)}, where T=(T_1+T_2)/2 is the average temperature of the layers. Clearly, increasing the number of layers and decreasing the emissivity both lower the heat transfer coefficient, which is equivalent to a higher insulation value. In space, where the apparent outside temperature could be 3 K (cosmic background radiation), the exact U value is different. The layers of MLI can be arbitrarily close to each other, as long as they are not in thermal contact. The separation space only needs to be minute, which is the function of the extremely thin scrim or polyester 'bridal veil' as shown in the photo. To reduce weight and blanket thickness, the internal layers are made very thin, but they must be opaque to thermal radiation. Since they don't need much structural strength, these internal layers are usually made of very thin plastic, about thick, such as Mylar or Kapton, coated on one or both sides with a thin layer of metal, typically silver or aluminium. For compactness, the layers are spaced as close to each other as possible, though without touching, since there should be little or no thermal conduction between the layers. A typical insulation blanket has 40 or more layers. The layers may be embossed or crinkled, so they only touch at a few points, or held apart by a thin cloth mesh, or scrim, which can be seen in the picture above. The outer layers must be stronger, and are often thicker and stronger plastic, reinforced with a stronger scrim material such as fiberglass. In satellite applications, the MLI will be full of air at launch time. As the rocket ascends, this air must be able to escape without damaging the blanket. This may require holes or perforations in the layers, even though this reduces their effectiveness. In cryogenics, the MLI is the most effective kind of insulation. Therefore, it is commonly used in liquefied gas tanks (e.g. LNG, , , ), cryostats, cryogenic pipelines and superconducting devices. Additionally it is valued for its compact size and weight. A blanket composed of 40 layers of MLI has thickness of about and weight of approximately . Methods tend to vary between manufacturers with some MLI blankets being constructed primarily using sewing technology. The layers are cut, stacked on top of each other, and sewn together at the edges. Other more recent methods include the use of Computer-aided design and Computer-aided manufacturing technology to weld a precise outline of the final blanket shape using Ultrasonic welding onto a "pack" (the final set of layers before the external "skin" is added by hand.) Seams and gaps in the insulation are responsible for most of the heat leakage through MLI blankets. A new method is being developed to use polyetheretherketone (PEEK) tag pins (similar to plastic hooks used to attach price tags to garments) to fix the film layers in place instead of sewing to improve the thermal performance.

External links

Satellite Thermal Control Handbook, ed. David Gilmore. . In particular, Chapter 5, Insulation, by Martin Donabedian and David Gilmore. Tutorial on temperature control of spacecraft by JPL Typical specialist article on tests of Cassini's MLI Multi-layer Insulation (MLI) Applications Multi layer insulation material guidelines-NASA publication from 1999 https://ntrs.nasa.gov/citations/19990047691 MLI types and properties

Text derived from https://en.wikipedia.org/w/index.php?oldid=1373023315 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

Extracted from the cited revision's reference blocks; absent citations are not invented.