Nanoindentation

Nanoindentation, also called instrumented indentation testing, is a variety of indentation hardness tests applied to small volumes.

Uses your system voice; voice and rate in settings.

Snapshot

≈ 10 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

Nanoindentation, also called instrumented indentation testing, is a variety of indentation hardness tests applied to small volumes. Indentation is perhaps the most commonly applied means of testing the mechanical properties of materials. The nanoindentation technique was developed in the mid-1970s to measure the hardness of small volumes of material.

H=\frac{P_\text{max}} {A_\text{r}}. For most techniques, the projected area may be measured directly using light microscopy. As can be seen from this equation, a given load will make a smaller indent in a "hard" material than a "soft" one.

This technique is limited due to large and varied tip shapes, with indenter rigs which do not have very good spatial resolution (the location of the area to be indented is very hard to specify accurately). Comparison across experiments, typically done in different laboratories, is difficult and often meaningless.

Nanoindentation improves on these macro- and micro-indentation tests by indenting on the nanoscale with a very precise tip shape, high spatial resolutions to place the indents, and by providing real-time load-displacement (into the surface) data while the indentation is in progress. In nanoindentation small loads and tip sizes are used, so the indentation area may only be a few square micrometres or even nanometres.

This presents problems in determining the hardness, as the contact area is not easily found. Atomic force microscopy or scanning electron microscopy techniques may be utilized to image the indentation, but can be quite cumbersome. Instead, an indenter with a geometry known to high precision (usually a Berkovich tip, which has a three-sided pyramid geometry) is employed.

During the course of the instrumented indentation process, a record of the depth of penetration is made, and then the area of the indent is determined using the known geometry of the indentation tip. While indenting, various parameters such as load and depth of penetration can be measured.

A record of these values can be plotted on a graph to create a load-displacement curve (such as the one shown in Figure 1). These curves can be used to extract mechanical properties of the material.

E_\text{r}=\frac{1}{\beta}\frac{\sqrt{\pi}}{2}\frac{S}{\sqrt{A_p(h_\text{c})}}, where A_p(h_\text{c}) is the projected area of the indentation at the contact depth h_c , and \beta is a geometrical constant on the order of unity. A_\text{p}(h_\text{c}) is often approximated by a fitting polynomial as shown below for a Berkovich tip: A_p(h_\text{c})=C_0h_\text{c}^2+C_1h_\text{c}^1+C_2h_\text{c}^{1/2}+C_3h_\text{c}^{1/4}+\ldots+C_8h_\text{c}^{1/128} where C_0 for a Berkovich tip is 24.5 while for a cube corner (90°) tip is 2.598.

The reduced modulus E_\text{r} is related to Young's modulus E_\text{s} of the test specimen through the following relationship from contact mechanics: 1/E_\text{r}=(1-\nu_i^2)/E_i+(1-\nu_s^2)/E_\text{s}. Here, the subscript i indicates a property of the indenter material and \nu is Poisson's ratio. For a diamond indenter tip, E_i is 1140 GPa and \nu_i is 0.07.

Poisson's ratio of the specimen, \nu_s , generally varies between 0 and 0.5 for most materials (though it can be negative) and is typically around 0.3. image of an indent left by a Berkovich tip in a Zr-Cu-Al metallic glass; the plastic flow of the material around the indenter is apparent.]] There are two different types of hardness that can be obtained from a nano indenter: one is as in traditional macroindentation tests where one attains a single hardness value per experiment; the other is based on the hardness as the material is being indented resulting in hardness as a function of depth.

H=\frac{P_\text{max}} {A_\text{r}}. m=\frac{\partial\ln{\sigma}}{\partial\ln{\dot{\varepsilon}}}, where \sigma=\sigma(\dot{\varepsilon}) is the flow stress and \dot{\varepsilon} is the strain rate produced under the indenter. For nanoindentation experiments which include a holding period at constant load (i.e. the flat, top area of the load-displacement curve), m can be determined from d\ln{H}=m d\ln{\dot{\varepsilon_p}}+n d\ln{h_p}.

The subscripts p indicate these values are to be determined from the plastic components only. V^*=9 k_\text{B} T \frac{\partial\ln{\dot{\varepsilon}}}{\partial H}, where T is the temperature and k B is the Boltzmann constant. From the definition of m , it is easy to see that V^*\propto (H m)^{-1} .

HM=\frac{P_\text{max}} {A_{s}}. The displacement is used to calculate the contact surface area, A_\text{s} , based on the indenter geometry. For a perfect Berkovich indenter the relationship is A_\text{s} = 24.5 h_\text{max}^2 .

The indentation hardness, H_\text{IT} is defined slightly different. H_\text{IT}=\frac{P_\text{max}} {A_\text{p}}. Here, the hardness is related to the projected contact area A_\text{p} .

As the indent size decreases the error caused by tip rounding increases. The tip wear can be accounted for within the software by using a simple polynomial function. As the indenter tip wears the C_1 value will increase.

The user enters the values for C_0 and C_1 based on direct measurements such as SEM or AFM images of the indenter tip or indirectly by using a material of known elastic modulus or an atomic force microscope (AFM) image of an indentation. A_\text{p} = C_0 h_\text{max}^2 + C_1 h_\text{max}.

Calculating the elastic modulus with software involves using software filtering techniques to separate the critical unloading data from the rest of the load-displacement data. The start and end points are usually found by using user defined percentages. This user input increases the variability because of possible human error.

It would be best if the entire calculation process was automatically done for more consistent results. A good nanoindentation machine prints out the load unload curve data with labels to each of the segments such as loading, top hold, unload, bottom hold, and reloading. If multiple cycles are used then each one should be labeled.

However mores nanoindenters only give the raw data for the load-unload curves. An automatic software technique finds the sharp change from the top hold time to the beginning of the unloading. This can be found by doing a linear fit to the top hold time data.

The unload data starts when the load is 1.5 times standard deviation less than the hold time load. The minimum data point is the end of the unloading data. The computer calculates the elastic modulus with this data according to the Oliver—Pharr (nonlinear).

The Doerner-Nix method is less complicated to program because it is a linear curve fit of the selected minimum to maximum data. However, it is limited because the calculated elastic modulus will decrease as more data points are used along the unloading curve.

The Oliver–Pharr nonlinear curve fit method to the unloading curve data where h is the depth variable, h_\text{f} is the final depth and k and m are constants and coefficients. The software must use a nonlinear convergence method to solve for k , h_\text{f} and m that best fits the unloading data. The slope is calculated by differentiating dP/dh at the maximum displacement.

P = k \left(h-h_{f}\right)^m. An image of the indent can also be measured using software. The atomic force microscope (AFM) scans the indent. First the lowest point of the indentation is found.

Make an array of lines around the using linear lines from indent center along the indent surface. Where the section line is more than several standard deviations (> 3 \sigma ) from the surface noise the outline point is created. Then connect all of the outline points to build the entire indent outline.

This outline will automatically include the pile-up contact area. For nanoindentation experiments performed with a conical indenter on a thin film deposited on a substrate or on a multilayer sample, the NIMS Matlab toolbox is useful for load-displacement curves analysis and calculations of Young's modulus and hardness of the coating.

In the case of pop-in, the PopIn Matlab toolbox is a solution to analyze statistically pop-in distribution and to extract critical load or critical indentation depth, just before pop-in. Finally, for indentation maps obtained following the grid indentation technique, the TriDiMap Matlab toolbox offers the possibility to plot 2D or 3D maps and to analyze statistically mechanical properties distribution of each constituent, in case of a heterogeneous material by doing deconvolution of probability density function.

A rate-jump method can be used to return an intrinsic elastic modulus of the sample that is independent of the test conditions. In this method, a constitutive law comprising any network of (in general) non-linear dashpots and linear elastic springs is assumed to hold within a very short time window about the time instant tc at which a sudden step change in the loading rate is applied on the sample.

Since the dashpots are described by relations of the form \dot\epsilon ij = \dot\epsilon ij ( \sigma kl ) but stress \sigma kl is continuous across the step change ∆ \dot\sigma ij in the stress rate field \dot\sigma kl at t c , there will not be any corresponding change in the strain rate field \dot\epsilon ij across the dashpots. However, because the linear elastic springs are described by relations of the form \epsilon ij  = S ikjl \sigma kl where S ikjl are elastic compliances, a step change ∆ \dot\epsilon ij across the springs will result according to ∆ \dot\epsilon ij = S ikjl ∆ \dot\sigma kl The last equation indicates that the fields ∆ \sigma kl and ∆ \dot\epsilon ij can be solved as a linear elastic problem with the elastic spring elements in the original viscoelastic network model while the dashpot elements are ignored.

The solution for a given test geometry is a linear relation between the step changes in the load and displacement rates at tc, and the linking proportionality constant is a lumped value of the elastic constants in the original viscoelastic model. Fitting such a relation to experimental results allows this lumped value to be measured as an intrinsic elastic modulus of the material.

Specific equations from this rate-jump method have been developed for specific test platforms. For example, in depth-sensing nanoindentation, the elastic modulus and hardness are evaluated at the onset of an unloading stage following a load-hold stage.

Such an onset point for unloading is a rate-jump point, and solving the equation \epsilon ij = S ikjl \sigma kl across this leads to the Tang–Ngan method of viscoelastic correction \frac{1}{S_\text{e}} = \frac{1}{2E_ra} = \frac{\Delta\dot h}{\Delta\dot P} = \frac{1}{S} - \frac{\dot h_\text{h}}{\dot P_\text{u}} where S = dP/dh is the apparent tip-sample contact stiffness at the onset of unload, \dot h_\text{h} is the displacement rate just before the unload, \dot P_\text{u} is the unloading rate, and S_\text{e} is the true (i.e. viscosity-corrected) tip-sample contact stiffness which is related to the reduced modulus E_\text{r} and the tip-sample contact size a by the Sneddon relation. The contact size a can be estimated from a pre-calibrated shape function f(h_\text{c})=\pi a^2 of the tip, where the contact depth h_\text{c} is obtainable using the Oliver—Pharr relation with the apparent contact stiffness S replaced by the true stiffness S_\text{e} : h_\text{c} = h_\text{max} - \epsilon \frac{P_\text{max}}{S_\text{e}} = h_\text{max} - \epsilon P_\text{max} \left(\frac{1}{S}-\frac{\dot h_\text{h}}{\dot P_\text{u}}\right) where \epsilon is a factor depending on the tip (say, 0.72 for Berkovich tip).

Text derived from https://en.wikipedia.org/w/index.php?oldid=1373049451 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

11 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.