Negative feedback
≈ 9 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
AB is negative. Negative feedback (or balancing feedback) occurs when some function of the output of a system, process, or mechanism is fed back in a manner that tends to reduce the fluctuations in the output, whether caused by changes in the input or by other disturbances. Whereas positive feedback tends to instability via exponential growth, oscillation or chaotic behavior, negative feedback generally promotes stability. Negative feedback tends to promote a settling to equilibrium, and reduces the effects of perturbations. Negative feedback loops in which just the right amount of correction is applied with optimum timing, can be very stable, accurate, and responsive. Negative feedback is widely used in mechanical and electronic engineering, and it is observed in many other fields including biology, chemistry and economics. General negative feedback systems are studied in control systems engineering. Negative feedback loops also play an integral role in maintaining the atmospheric balance in various climate systems on Earth. One such feedback system is the interaction between solar radiation, cloud cover, and planet temperature.
AB is negative. Negative feedback (or balancing feedback) occurs when some function of the output of a system, process, or mechanism is fed back in a manner that tends to reduce the fluctuations in the output, whether caused by changes in the input or by other disturbances. Whereas positive feedback tends to instability via exponential growth, oscillation or chaotic behavior, negative feedback generally promotes stability. Negative feedback tends to promote a settling to equilibrium, and reduces the effects of perturbations. Negative feedback loops in which just the right amount of correction is applied with optimum timing, can be very stable, accurate, and responsive. Negative feedback is widely used in mechanical and electronic engineering, and it is observed in many other fields including biology, chemistry and economics. General negative feedback systems are studied in control systems engineering. Negative feedback loops also play an integral role in maintaining the atmospheric balance in various climate systems on Earth. One such feedback system is the interaction between solar radiation, cloud cover, and planet temperature.
Engineering
Mercury thermostats (circa 1600) using expansion and contraction of columns of mercury in response to temperature changes were used in negative feedback systems to control vents in furnaces, maintaining a steady internal temperature. In centrifugal governors (1788), negative feedback is used to maintain a near-constant speed of an engine, irrespective of the load or fuel-supply conditions. In a steering engine (1866), power assistance is applied to the rudder with a feedback loop, to maintain the direction set by the steersman. In servomechanisms, the speed or position of an output, as determined by a sensor, is compared to a set value, and any error is reduced by negative feedback to the input.
Biology
In organisms, feedback enables many measures (e.g. body temperature, thyroid hormone level, blood electrolyte levels, and blood sugar level) to be maintained within a desired range by homeostatic processes.
Social sciences
In the invisible hand of the market metaphor of economic theory (1776), reactions to price movements provide a feedback mechanism to match supply and demand.
Error-controlled regulation
One use of feedback is to make a system (say T) self-regulating to minimize the effect of a disturbance (say D). Using a negative feedback loop, a measurement of some variable (for example, a process variable, say E) is subtracted from a required value (the 'set point') to estimate an operational error in system status, which is then used by a regulator (say R) to reduce the gap between the measurement and the required value. The regulator modifies the input to the system T according to its interpretation of the error in the status of the system. This error may be introduced by a variety of possible disturbances or 'upsets', some slow and some rapid. The regulation in such systems can range from a simple 'on-off' control to a more complex processing of the error signal. In this framework, the physical form of a signal may undergo multiple transformations. For example, a change in weather may cause a disturbance to the heat input to a house (as an example of the system T) that is monitored by a thermometer as a change in temperature (as an example of an 'essential variable' E). This quantity, then, is converted by the thermostat (a 'comparator') into an electrical error in status compared to the 'set point' S, and subsequently used by the regulator (containing a 'controller' that commands gas control valves and an ignitor) ultimately to change the heat provided by a furnace (an 'effector') to counter the initial weather-related disturbance in heat input to the house. Error controlled regulation is typically carried out using a Proportional-Integral-Derivative Controller (PID controller). The regulator signal is derived from a weighted sum of the error signal, integral of the error signal, and derivative of the error signal. The weights of the respective components depend on the application. Mathematically, the regulator signal is given by: \mathrm{MV(t)}=K_p\left(\,{e(t)} + \frac{1}{T_i}\int_{0}^{t}{e(\tau)}\,{d\tau} + T_d\frac{d}{dt}e(t)\right) where T_i is the integral time T_d is the derivative time
Negative feedback amplifier
The negative feedback amplifier was invented by Harold Stephen Black at Bell Laboratories in 1927, and granted a patent in 1937 (US Patent 2,102,671) "a continuation of application Serial No. 298,155, filed August 8, 1928 ..."). "The patent is 52 pages long plus 35 pages of figures. The first 43 pages amount to a small treatise on feedback amplifiers!" There are many advantages to feedback in amplifiers. In design, the type of feedback and amount of feedback are carefully selected to weigh and optimize these various benefits.
Advantages of amplifier negative voltage feedback
Negative voltage feedback in amplifiers has the following advantages; it reduces non-linear distortion, i.e., produces higher fidelity; increases circuit stability: i.e., gains remain stable over variations in ambient temperature, frequency, and signal amplitude; slightly increases bandwidth; modifies input and output impedances; considerably reduces harmonic, phase, amplitude, and frequency distortions; and considerably reduces noise. Though negative feedback has many advantages, amplifiers with feedback can oscillate (see Step response of feedback amplifiers), and they may exhibit instability. Harry Nyquist of Bell Laboratories proposed the a stability criterion and a plot to identify stable feedback systems, including amplifiers and control systems. The figure shows a simplified block diagram of a negative feedback amplifier. The feedback sets the overall (closed-loop) amplifier gain at a value: \frac{O}{I} =\frac {A} { 1+\beta A } \approx \frac {1}{\beta} \ , where the approximate value assumes βA >> 1. This expression shows that a gain greater than one requires β O =\frac {AI} { 1+\beta A } +\frac {D}{1+ \beta A} \ , which shows that the feedback reduces the effect of the disturbance by the 'improvement factor' (1+β A). The disturbance D might arise from fluctuations in the amplifier output due to noise and nonlinearity (distortion) within this amplifier, or from other noise sources such as power supplies. The difference signal I–βO at the amplifier input is sometimes called the "error signal". According to the diagram, the error signal is: \text{Error signal} = I - \beta O = I \left ( 1-\beta \frac{O}{I} \right ) =\frac {I} {1 + \beta A} - \frac { \beta D} {1+\beta A} \ . From this expression, it can be seen that a large 'improvement factor' (or a large loop gain βA) tends to keep this error signal small. Although the diagram illustrates the principles of the negative feedback amplifier, modeling a real amplifier as a unilateral forward amplification block and a unilateral feedback block has significant limitations. For methods of analysis that do not make these idealizations, see the article Negative feedback amplifier.
Operational amplifier circuits
The operational amplifier was originally developed as a building block for the construction of analog computers, but is now used almost universally in all kinds of applications including audio equipment and control systems. Operational amplifier circuits typically employ negative feedback to get a predictable transfer function. Since the open-loop gain of an op-amp is extremely large, a small differential input signal would drive the output of the amplifier to one rail or the other in the absence of negative feedback. A simple example of the use of feedback is the op-amp voltage amplifier shown in the figure. The idealized model of an operational amplifier assumes that the gain is infinite, the input impedance is infinite, output resistance is zero, and input offset currents and voltages are zero. Such an ideal amplifier draws no current from the resistor divider. Ignoring dynamics (transient effects and propagation delay), the infinite gain of the ideal op-amp means this feedback circuit drives the voltage difference between the two op-amp inputs to zero. Consequently, the voltage gain of the circuit in the diagram, assuming an ideal op amp, is the reciprocal of feedback voltage division ratio β: V_{\text{out}} = \frac{ R_{\text{1}} + R_{\text{2}} }{ R_{\text{1}} } V_{\text{in}}\! = \frac{1}{\beta} V_{\text{in}} \, . A real op-amp has a high but finite gain A at low frequencies, decreasing gradually at higher frequencies. In addition, it exhibits a finite input impedance and a non-zero output impedance. Although practical op-amps are not ideal, the model of an ideal op-amp often suffices to understand circuit operation at low enough frequencies. As discussed in the previous section, the feedback circuit stabilizes the closed-loop gain and desensitizes the output to fluctuations generated inside the amplifier itself.
Self-organization
Self-organization is the capability of certain systems "of organizing their own behavior or structure". There are many possible factors contributing to this capacity, and most often positive feedback is identified as a possible contributor. However, negative feedback also can play a role.
See also
Text derived from https://en.wikipedia.org/w/index.php?oldid=1372051696 under CC BY-SA 4.0; modifications have been made.