A NetApp FAS is a computer storage product by NetApp running the ONTAP operating system; the terms ONTAP, FAS, AFF, and ASA are often used as synonyms.
≈ 13 min read
NetApp FAS. encyclopegia.org, snapshot enwiki-001362487093. /a/netapp-fas
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
A NetApp FAS is a computer storage product by NetApp running the ONTAP operating system; the terms ONTAP, FAS, AFF, and ASA are often used as synonyms. "Filer" is also used as a synonym although this is not an official name.
There are several types of custom-built hardware appliances: Fabric Attached Storage (FAS) - combine Serial Attached SCSI (SAS) SSDs and HDDs to provide a hybrid storage system optimized for capacity and cost-effectiveness; All-Flash FAS (AFF) - based on NVMe SSDs (TLC for extreme performance, or QLC for high-capacity) optimized for low-latency; All-Flash SAN Array (ASA) - built on top of the AFF platform, providing a high-performance block-only storage system. ONTAP can provide network-attached storage (NAS) using file-based protocols such as NFS or SMB and object-based protocols such as S3, as well as service on a storage area network (SAN) using block-based protocols, such as SCSI over the Fibre Channel Protocol on Fibre Channel or on Fibre Channel over Ethernet (FCoE), iSCSI, and FC-NVMe.
ONTAP-based systems that can serve SAN, file, and NAS protocols are called Unified ONTAP, AFF systems with ASA identity are called All-SAN. Early FAS storage systems connected to external disk enclosures via parallel SCSI, while modern models ( ) use SCSI over Fibre Channel and SAS.
While most large-storage systems are implemented with commodity computers with an operating system such as Microsoft Windows Server, VxWorks or tuned Linux, ONTAP-based hardware appliances use highly customized hardware and the proprietary Data ONTAP operating system with WAFL file system, all originally designed by NetApp founders David Hitz and James Lau specifically for storage-serving purposes. ONTAP is NetApp's internal operating system, specially optimized for storage functions at high and low levels.
All NetApp ONTAP-based hardware appliances have battery-backed non-volatile random access memory (NVRAM) or NVDIMM, which allows them to commit writes to stable storage more quickly than traditional systems with only volatile memory. Starting with AFF A800 NVRAM PCI card no longer used for NVLOGs, it was replaced with NVDIMM memory directly connected to the memory bus.
Implementers often organize two storage systems in a high-availability cluster with a private high-speed link, either Fibre Channel, InfiniBand, 10 Gigabit Ethernet, 40 Gigabit Ethernet or 100 Gigabit Ethernet. One can additionally group such clusters together under a single namespace when running in the "cluster mode" of the Data ONTAP 8 operating system.
Disks
FAS, ASA, and AFF systems are using enterprise-level HDD and SSD (i.e. NVMe SSD) drives with two ports, each port connected to each controller in an HA pair. HDD and SSD drives can only be bought from NetApp and installed in NetApp's Disk Shelves for FAS/AFF platform. Some shelves, such as the D4246, can be upgraded from a 6 Gbit/s Shelf into a 12 Gbit/s with an IOM-12 upgrade.
Physical HDD and SSD drives, partitions on them, and LUNs imported from third-party arrays with FlexArray functionality considered in ONTAP as a Disk. In SDS systems like ONTAP Select & ONTAP Cloud, logical block storage like virtual disk or RDM inside ONTAP also considered as a Disk.
Do not confuse the general term "disk drive" and "disk drive term used in ONTAP system" because, with ONTAP, it could be an entire physical HDD or SSD drive, a LUN, or a partition on a physical HDD or SSD drive. LUNs imported from third-party arrays with FlexArray functionality in HA pair configuration must be accessible from both nodes of the HA pair.
Each disk has ownership on it to show which controller owns and serves the disk. An aggregate can include only disks owned by a single node, therefore each aggregate owned by a node and any objects on top of it, as FlexVol volumes, LUNs, File Shares are served with a single controller.
Each controller can have its own disks and aggregates them where both nodes can be utilized simultaneously even though they not serving the same data.
ADP
Advanced Drive Partitioning (ADP) can be used in ONTAP-based systems depending on the platform and use-case. ADP can be used only with native disk drives from NetApp Disk shelves, FlexArray technology does not support ADP. ADP also supported with third-party drives in ONTAP Select.
This technique mainly used to overcome some architectural requirements and reduce the number of disk drives in ONTAP-based systems. There are three types of ADP: Root-Data partitioning; Root-Data-Data partitioning (RD2 also known as ADPv2); Storage Pool.
Root-Data partitioning can be used in FAS & AFF systems to create small root partitions on drives to use them to create system root aggregates and, therefore, not to spend entire three disk drives for that purpose. In contrast, the bigger portion of the disk drive will be used for data aggregate.
Root-Data-Data partitioning is used in AFF systems only for the same reason as Root-Data partitioning with the only difference that bigger portion of the drive left after root partitioning divided equally by two additional partitions, usually, each partition assigned to one of the two controllers, therefore reducing the minimum number of drives required for an AFF system and reducing waste for expensive SSD space. Storage Pool partitioning technology used in FAS systems to equally divide each SSD drive by four pieces which later can be used for FlashPool cache acceleration, with Storage Pool only a few SSD drives can be divided by up to 4 data aggregates which will benefit from FlashCache caching technology reducing minimally required SSD drives for that technology.
NetApp RAID in ONTAP
In NetApp ONTAP systems, RAID and WAFL are tightly integrated. There are several RAID types available within ONTAP-based systems: RAID 4 with 1 dedicated parity disk allowing any 1 drive to fail in a RAID group. RAID-DP with 2 dedicated parity disks allowing any 2 drives to fail simultaneously in a RAID group.
RAID-TEC with 3 dedicated parity drives, allows any 3 drives to fail simultaneously in a RAID group. RAID-DP's double parity leads to a disk loss resiliency similar to that of RAID 6. NetApp overcomes the write performance penalty of traditional RAID-4 style dedicated parity disks via WAFL and a novel use of its nonvolatile memory (NVRAM) within each storage system.
Each aggregate consist of one or two plexes, a plex consists of one or more RAID groups. Typical ONTAP-based storage system have only 1 plex in each aggregate, two plexes used in local SyncMirror or MetroCluster configurations. Each RAID group usually consists of disk drives of same type, speed, geometry and capacity.
Though NetApp Support could allow a user to install a drive to a RAID group with same or bigger size and different type, speed and geometry for temporary basis. Ordinary data aggregates if containing more than one RAID group must have same RAID groups across the aggregate, same RAID group size is recommended, but NetApp allows to have exception in last RAID group and configure it as small as half of the RAID group size across aggregate.
For example, such an aggregate might consists of 3 RAID groups: RG0:16+2, RG1:16+2, RG2:7+2. Within aggregates, ONTAP sets up flexible volumes (FlexVol) to store data that users can access. Aggregates enabled as FlshPool and with both HDD and SSD drives called hybrid aggregates.
In Flash Pool hybrid aggregates same rules applied to the hybrid aggregate as to ordinary aggregates but separately to HDD and SSD drives, thus it is allowed to have two different RAID types: only one RAID type for all HDD drives and only one RAID type for all SSD drives in a single hybrid aggregate. For example, SAS HDD with RAID-TEC (RG0:18+3, RG1:18+3) and SSD with RAID-DP (RG3:6+2).
NetApp storage systems running ONTAP combine underlying RAID groups similarly to RAID 0. Also, in NetApp FAS systems with FlexArray feature, the third-party LUNs could be combined in a Plex similarly to RAID 0.
NetApp storage systems running ONTAP can be deployed in MetroCluster and SyncMirror configurations, which are using technique comparably to RAID 1 with mirroring data between two plexes in an aggregate.
FlexArray
FlexArray is NetApp FAS functionality allows to visualize third party storage systems and other NetApp storage systems over SAN protocols and use them instead of NetApp's disk shelves. With FlexArray functionality RAID protection must be done with third party storage array thus NetApp's RAID 4, RAID-DP and RAID-TEC not used in such configurations.
One or many LUNs from third party arrays could be added to a single aggregate similarly to RAID 0. FlexArray is licensed feature.
MCC
With MetroCluster it is possible to have one or more storage node per site to form a cluster or Clustered MetroCluster (MCC). Remote and local HA perter node must be the same model. MCC consists of two clusters each located on one of two sites.
There may be only two sites. In MCC configuration each one remote and one local storage node form Metro HA or Disaster Recovery Pare (DR Pare) across two sites while two local nodes (if there is partner) form local HA pare, thus each node synchronously replicates data in non-volatile memory two nodes: one remote and one local (if there is one).
It is possible to utilize only one storage node on each site (two single node clusters) configured as MCC. 8 node MCC consists of two clusters - 4 nodes each (2 HA pair), each storage node have only one remote partner and only one local HA partner, in such a configuration each site clusters can consist out of two different storage node models.
For small distances, MetroCluster requires at least one FC-VI or newer iWARP card per node. FAS and AFF systems with ONTAP software versions 9.2 and older utilize FC-VI cards and for long distances require 4 dedicated Fibre Channel switches (2 on each site) and 2 FC-SAS bridges per each disk shelf stack, thus minimum 4 total for 2 sites and minimum 2 dark fiber ISL links with optional DWDMs for long distances.
Data volumes, LUNs and LIFs could online migrate across storage nodes in the cluster only within a single site where data originated from: it is not possible to migrate individual volumes, LUNs or LIFs using cluster capabilities across sites unless MetroCluster switchover operation is used which disable entire half of the cluster on a site and transparently to its clients and applications switch access to all of the data to another site.
MCC-IP
Starting with ONTAP 9.3 MetroCluster over IP (MCC-IP) was introduced with no need for a dedicated back-end Fibre Channel switches, FC-SAS bridges and dedicated dark fiber ISL which previously were needed for a MetroCluster configuration. Initially, only A700 & FAS9000 systems supported with MCC-IP.
MCC-IP available only in 4-node configurations: 2-node Highly Available system on each site with two sites total. With ONTAP 9.4, MCC-IP supports A800 system and Advanced Drive Partitioning in form of Rood-Data-Data (RD2) partitioning, also known as ADPv2. ADPv2 supported only on all-flash systems.
MCC-IP configurations support single disk shelf where SSD drives partitioned in ADPv2. MetroCluster over IP require Ethernet cluster switches with installed ISL and utilize iWARP cards in each storage controller for synchronous replication. Starting with ONTAP 9.5 MCC-IP supports distance up to 700 km and starts to support SVM-DR feature, AFF A300, and FAS8200 systems.
7MTT
Each NetApp FAS system running Data ONTAP 8 could switch between modes either 7-Mode or Cluster mode. In reality each mode was a separate OS with its own version of WAFL, both 7-mode and Cluster mode where shipped on a single firmware image for a FAS system till 8.3 where 7-mode was deprecated. SnapLock migration from 7-Mode to ONTAP 9 now supported with Transition Tool.
It is possible to switch between modes on a FAS system but all the data on disks must be destroyed first since WAFL is not compatible and server-based application called 7MTT tool was introduced to migrate data from old 7-mode FAS system to new Cluster-Mode: With SnapMirror based replication called Copy-based transition which helped to migrate all the data with planned downtime using only storage vendor capabilities. Copy-based transition require new controllers and disks with space no less than on source system if all the data to be migrated.
Both SAN and NAS data are possible. Starting with 7-mode 8.2.1 and Cluster-Mode 8.3.2 WAFL compatibility where introduced and new feature in 7MTT tool called Copy-free transition to replace old controllers running 7-mode with new controllers running Cluster-Mode and planned downtime, while new system require additional system disks with root aggregates for new controllers (it could be as less as 6 disks).
Since with Copy-free transition no data copying required 7MTT tool helping only for new controllers reconfiguration. Both SAN and NAS data conversion supported.
Additional to 7MTT there are two other paths to migrate data based on protocol type: SAN data could be copied with foreign LUN import (FLI) functionality integrated in NetApp FAS system which can copy data over SAN protocol while new storage system running ONTAP placed as SAN proxy between hosts and old storage system which require host reconfiguration and minimum downtime. FLI available as for old 7-mode systems and for some models of storage systems of competitors.
NAS data could be copied with NetApp XCP free host-based utility thus host-based copy process processed with the utility from any copying data from source server with SMB or NFS protocols to ONTAP system with minimal downtime for client systems reconfiguration for new NAS server. EOA = End of Availability SPECsfs with "*" is clustered result.