Parallel-plate flow chamber

A parallel-plate fluid flow chamber is a benchtop (in vitro) model that simulates fluid shear stresses on various cell types exposed to dynamic fluid flow in their natural, physiological environment.

Uses your system voice; voice and rate in settings.

Snapshot

≈ 4 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

A parallel-plate fluid flow chamber is a benchtop (in vitro) model that simulates fluid shear stresses on various cell types exposed to dynamic fluid flow in their natural, physiological environment. The metabolic response of cells in vitro is associated with the wall shear stress.

A typical parallel-plate flow chamber consists of a polycarbonate distributor, a silicon gasket, and a glass coverslip. The distributor, forming one side of the parallel-plate flow chamber, includes inlet port, outlet port, and a vacuum slot. The thickness of the gasket determines the height of the flow path.

The glass coverslip forms another side of the parallel-plate flow chamber and can be coated with extracellular matrix (ECM) proteins, vascular cells, or biomaterials of interest. A vacuum forms a seal to hold these three parts and ensures a uniform channel height. Typically, the fluid enters one side of the chamber and leaves from an opposite side.

The upper plate is usually transparent while the bottom is a prepared surface on which the cells have been cultured for a predetermined period. Cell behavior is viewed with either transmitted or reflective light microscope. \rho\left(\frac{\partial V_x}{\partial t} + V_x\frac{\partial V_x}{\partial x} + V_y\frac{\partial V_x}{\partial y} + V_z\frac{\partial V_x}{\partial z}\right) = \frac{\partial P}{\partial x} + \mu \left(\frac{\partial ^2V_x}{\partial x^2} + \frac{\partial ^2V_x}{\partial y^2} + \frac{\partial ^2V_x}{\partial z^2}\right) + \rho g_x With the assumptions such as Newtonian Fluid, Incompressible, Laminar Flow and no slip boundary conditions, Navier-Stokes equations simplifies to: -\frac{\partial P}{\partial x} = \mu \left(\frac{\partial ^2V_x}{\partial y^2}\right) Solving the first differential equation will provide: -\frac{\partial P}{\partial x} y = \mu \left(\frac{\partial V_x}{\partial y}\right) + C Solving the second differential equation for no slip boundary condition the velocity profile is given by: V_x = \frac{1}{2\mu} \frac{\partial P}{\partial x}(H^2 - y^2) This can then be used in continuity equation that states: Q = \int\int_A V_x dA = W \int_{-H} ^H \frac{1}{2\mu} \frac{\partial P}{\partial x}(H^2 - y^2) dy Solving this integral will output: Q = \frac{2WH^3}{3\mu} \frac{\partial P}{\partial x} When solving the equation for the change in pressure and plugging it into the first differential equation the shear stress can be calculated for the parallel plate flow chamber. \tau = -\mu \frac{\partial V_x}{\partial y} = \frac{\partial P}{\partial x} H = \frac{3Q\mu}{2WH^2} In which μ is the dynamic viscosity, and w the width of the flow chamber.

In these methods, the shear stresses exerted on the cells are assumed approximately equal to the chamber wall shear stresses since cell height is approximately two orders of magnitude less than the chamber.

Application

The parallel-plate flow chamber is a widely used piece of equipment for studying cellular mechanics on the benchtop. Many researchers used parallel-plate flow chambers to investigate the dynamic adhesion between leukocytes (white blood cells) and endothelial cells (blood vessel lining cells) under definite shear stress.

In particular, some studies have been carried out to study leukocyte receptor-ligand interactions. Interactions between cell receptors (selectins and/or integrins) and their ligands mediate rolling and are believed to play an important role in leukocyte adhesion.

Moreover, many researchers used parallel-plate flow chambers to provide shear stress and to mimic the environment of cancer cell growth outside of the body. It is a versatile tool in understanding the mechanisms of proliferation, adhesion, and metastasis of cancer cells.

Parallel plate flow chambers are widely used also for drug testing in the cellular chemotaxis assay and for novel targeted drug delivery systems based on leukocyte-endothelium adhesion processes.

Text derived from https://en.wikipedia.org/w/index.php?oldid=1280985596 under CC BY-SA 4.0; modifications have been made.

Provenance

snapshot enwiki-001280985596 · captured 2025-03-17 · not yet sealed in the ledger · verify the chain · version history

Cite this page as: encyclopegia.org, “Parallel-plate flow chamber”, snapshot enwiki-001280985596. https://encyclopegia.org/a/parallel-plate-flow-chamber

Sources cited in this revision

No external citation was extracted for this revision. That is a statement about the source, not a claim that none exists.