Piezospectroscopy (also known as photoluminescence piezospectroscopy) is an analytical technique that reveals internal stresses in alumina-containing materials, particularly thermal barrier coatings (TBCs). A typical procedure involves illuminating the sample with laser light of a known wavelength, causing the material to release its own radiation in response (see fluorescence). By measuring the emitted radiation and comparing the location of the peaks to a stress-free sample, stresses in the material can be revealed without any destructive interaction. Piezospectroscopy can be used on any material that exhibits fluorescence, but is almost exclusively used on samples containing alumina because of the presence of chromium ions, either as part of the composition or as an impurity, that greatly increase the fluorescent response. As opposed to other methods of stress measurement, such as powder diffraction or the use of a strain gauge, piezospectroscopy can measure internal stresses at higher resolution, on the order of 1 μm, and can measure very quickly, with most systems taking less than one second to acquire data.

Piezospectroscopy (also known as photoluminescence piezospectroscopy) is an analytical technique that reveals internal stresses in alumina-containing materials, particularly thermal barrier coatings (TBCs). A typical procedure involves illuminating the sample with laser light of a known wavelength, causing the material to release its own radiation in response (see fluorescence). By measuring the emitted radiation and comparing the location of the peaks to a stress-free sample, stresses in the material can be revealed without any destructive interaction. Piezospectroscopy can be used on any material that exhibits fluorescence, but is almost exclusively used on samples containing alumina because of the presence of chromium ions, either as part of the composition or as an impurity, that greatly increase the fluorescent response. As opposed to other methods of stress measurement, such as powder diffraction or the use of a strain gauge, piezospectroscopy can measure internal stresses at higher resolution, on the order of 1 μm, and can measure very quickly, with most systems taking less than one second to acquire data. v = {c \over \lambda} where v is the frequency, λ is the wavelength, and c is the speed of light. If the coating is under a compressive stress, the peaks will be shifted downward while a tensile stress will shift them upward. The frequency shift is given by the equation: \Delta v= {2 \over 3} \amalg_{ii} \sigma_{av} where \amalg_{ii} is the piezospectroscopic tensor and \sigma_{av} is the residual stress within the coating.

Text derived from https://en.wikipedia.org/w/index.php?oldid=1374062840 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

3 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.