Plug load

Plug load is the energy used by products that are powered by means of an ordinary AC plug (e.g., 100, 115, or 230 V).

Uses your system voice; voice and rate in settings.

Snapshot

≈ 5 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

Plug load is the energy used by products that are powered by means of an ordinary AC plug (e.g., 100, 115, or 230 V).[1] This term generally excludes building energy that is attributed to major end uses (HVAC, lighting, water heating, etc.)[1]

Definitions

edit edit source

Plug loads are often synonymous with terms such as "receptacle loads", "miscellaneous loads", "unregulated loads", or "process energy/loads." While many building codes/standards haven't defined "plug loads" specifically, they have defined these related terms, which are usually broader energy use categories.

"Process energy" is defined as energy consumed in support of a manufacturing, industrial, or commercial process other than conditioning spaces and maintaining comfort and amenities for the occupants of a building.[2] It typically includes office and general miscellaneous equipment, computers, elevators and escalators, kitchen cooking and refrigeration, laundry washing and drying, lighting exempt from the lighting power allowance, and other energy uses.[3]

"Receptacle loads" has been defined as equipment loads normally served through electrical receptacles, such as office equipment and printers, but does not include either task lighting or equipment used for HVAC purposes.[4]

Energy use

edit edit source

In 1999, the US Department of Energy projected that office equipment would be the fastest-growing commercial end use between 1998 and 2020.[5] The Commercial Buildings Energy Consumption Survey (CBECS), a national sample survey project of the US Energy Information Administration, reported that based on 2003 data, 19% of the total energy of US office buildings is attributed to plug load energy use (office equipment, computers, and other energy use).[6]

One confounding factor with estimating plug load energy use is the discrepancy between the rated or nameplate energy power consumption and the actual average power consumption, which can be as little as 10-15% of the nameplate value.[7]

Office equipment and other plug loads emit heat which may require the building to supply additional cooling, a side-effect which contributes to total energy consumption. However, when heating is needed, waste heat from plug loads also supplies part of the energy requirement for heating. Heating a space with electric heating is environmentally less effective than using the electricity for heat pumps, however if the electricity is being consumed anyway this is not a factor.

Plug load energy efficiency

edit edit source

In general, although total plug load energy use is increasing, the actual plug load equipment stock is getting more efficient; technical advances such as low power consumption by LCD monitors, more effective sleep modes, and the uptake of the notebook laptop computer in lieu of a desktop computer have produced lower plug load power levels.[8]

Plug load energy efficiency programs such as Energy Star help distinguish energy efficient plug load/office equipment products to consumers. Energy Star labeled computers, fax machines, scanners, and printers have demonstrated over 50% energy savings as compared to standard equipment.[9]

User behavior and power management

edit edit source

Although the efficiency of this equipment category is improving, many studies have indicated that user behavior may be a factor for its overall increasing energy use. In one study of 11 after-hours walk-throughs of offices in San Francisco and Washington DC, "only 44 percent of computers, 32 percent of monitors, and 25 percent of printers were turned off at night".[10]

Additionally, equipment power management adds some uncertainty to estimating plug load energy use. While most plug load products have "off" and "on" states, the "sleep" or "low power" states can represent a wide range of power savings, from 55% in desktop computers to 94% in CRT monitors.[11]

See also

edit edit source

References

edit edit source
  1. ^ a b Nordman, Bruce; Marla McWhinney (2006). "Electronics Come of Age: A Taxonomy for Miscellaneous and Low Power Products". ACEEE Summer Study on Energy Efficiency in Buildings. Washington, D.C.: ACEEE. Wikipedia revision 1321828397, retrieved 2026-11-18
  2. ^ ASHRAE (2010). ANSI/ASHRAE Standard 90.1-2010: Energy Standard for Buildings Except Low-Rise Residential Buildings. Atlanta, GA: American Society of Heating, Refrigerating and Air-Conditioning Engineers. Wikipedia revision 1321828397, retrieved 2026-11-18
  3. ^ U.S. Green Building Council (October 2007). LEED for New Construction & Major Renovation Version 2.2 Reference Guide (Third ed.). U.S. Green Building Council. ISBN 978-1-932444-11-7. Wikipedia revision 1321828397, retrieved 2026-11-18
  4. ^ COMNET (2010). Commercial Buildings Energy Modeling Guidelines and Procedures. Oceanside, CA: Commercial Energy Services Network. Wikipedia revision 1321828397, retrieved 2026-11-18
  5. ^ Energy Information Administration (1999), Annual Energy Outlook 2000 with Projections to 2020, U.S. Department of Energy Wikipedia revision 1321828397, retrieved 2026-11-18
  6. ^ "Commercial Buildings Energy Consumption Survey". U.S. Energy Information Administration. Retrieved 28 November 2011. Wikipedia revision 1321828397, retrieved 2026-11-18
  7. ^ Hosni, M. H.; Beck, B. T. (2009), Update to Measurements of Office Equipment Heat Gain Data, Final Report, ASHRAE Research Project RP-148 Wikipedia revision 1321828397, retrieved 2026-11-18
  8. ^ Wilkins, Christopher K.; Mohammad H. Hosni (2011). "Plug Load Design Factors". ASHRAE Journal. 53 (5): 30–34. Wikipedia revision 1321828397, retrieved 2026-11-18
  9. ^ Webber, C. A.; R. E. Brown; J. Koomey (2000). "Savings Estimates for the ENERGY STAR® Voluntary Labeling Program". Energy Policy. 28 (15): 1137–49. doi:10.1016/s0301-4215(00)00083-5. S2CID 150599301. Wikipedia revision 1321828397, retrieved 2026-11-18
  10. ^ Webber, C. a. (2001). "Field Surveys of Office Equipment Operating Patterns". Draft Report, LBNL-46930. {{cite journal}}: Cite journal requires |journal= (help) Wikipedia revision 1321828397, retrieved 2026-11-18
  11. ^ Webber, C. a. (2006). "After-Hours Power Status of Office Equipment in the USA" (PDF). Energy. 31 (14): 2823–38. doi:10.1016/j.energy.2005.11.007. S2CID 55695969. Wikipedia revision 1321828397, retrieved 2026-11-18

Text derived from https://en.wikipedia.org/w/index.php?oldid=1321828397 under CC BY-SA 4.0; modifications have been made.