Lesson plan
Positive-real function
Positive-real functions, often abbreviated to PR function or PRF, are a kind of mathematical function that first arose in electrical network synthesis. They are complex functions, Z(s), of a complex variable, s. A rational function is defined to have the PR property if it has a positive real part and is analytic in the right half of the complex plane and takes on real values on the real axis. That is: : \begin{align} & \Re[Z(s)]>0 \quad\text{if}\quad \Re(s) > 0 \\ & \Im[Z(s)]=0 \quad\text{if}\quad \Im(s)=0 \end{align} In electrical network analysis, Z(s) represents an impedance expression and s is the complex frequency variable, often expressed as its real and imaginary parts; : s=\sigma+i\omega \,\! in which terms the PR condition can be stated; : \begin{align} & \Re[Z(s)]>0 \quad\text{if}\quad \sigma > 0 \\ & \Im[Z(s)]=0 \quad\text{if}\quad \omega=0 \end{align} The importance to network analysis of the PR condition lies in the realisability condition. Z(s) is realisable as a one-port rational impedance if and only if it meets the PR condition. Realisable in this sense means that the impedance can be constructed from a finite (hence rational) number of discrete ideal passive linear elements (resistors, inductors and capacitors in electrical terminology).
Article summary
Positive-real functions, often abbreviated to PR function or PRF, are a kind of mathematical function that first arose in electrical network synthesis. They are complex functions, Z(s), of a complex variable, s. A rational function is defined to have the PR property if it has a positive real part and is analytic in the right half of the complex plane and takes on real values on the real axis. That is: : \begin{align} & \Re[Z(s)]>0 \quad\text{if}\quad \Re(s) > 0 \\ & \Im[Z(s)]=0 \quad\text{if}\quad \Im(s)=0 \end{align} In electrical network analysis, Z(s) represents an impedance expression and s is the complex frequency variable, often expressed as its real and imaginary parts; : s=\sigma+i\omega \,\! in which terms the PR condition can be stated; : \begin{align} & \Re[Z(s)]>0 \quad\text{if}\quad \sigma > 0 \\ & \Im[Z(s)]=0 \quad\text{if}\quad \omega=0 \end{align} The importance to network analysis of the PR condition lies in the realisability condition. Z(s) is realisable as a one-port rational impedance if and only if it meets the PR condition. Realisable in this sense means that the impedance can be constructed from a finite (hence rational) number of discrete ideal passive linear elements (resistors, inductors and capacitors in electrical terminology).
Key claims
No claims recorded.
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?
Bibliography
No sources recorded.
Key claims and bibliography are generated from the same tracked claims and sources as the article page.