Lesson plan
Push–pull perfusion
Push–pull perfusion is an in vivo sampling method most commonly used for measuring neurotransmitters in the brain. Developed by J.H. Gaddum in 1960, this technique replaced the cortical cup technique for observing neurotransmitters. In order to analyze concentrations of analytes such as neurotransmitters, a probe consisting of two concentric tubes is implanted in the region of interest. A pump then pushes a neutral fluid such as saline or Ringer's solution through one of the tubes, while another pump extracts the fluid through the other tube. While outside the tubes, the perfusion fluid picks up physiological substances such as neurotransmitters that are present in the area. The concentration of analytes of interest can then be measured in the expelled fluid, indicating in which concentration they are present at the site of interest at any given time. The advent of concentric microdialysis probes in the 1980s resulted in push-pull sampling falling out of favor, as such probes require less monitoring, and are less invasive than the higher flow rate push-pull probes (>10 microliter/min), which could result in lesions if flow is unbalanced. With the advent of microfluidics and miniaturized probes, low-flow push–pull sampling was developed in 2002.…
Article summary
Push–pull perfusion is an in vivo sampling method most commonly used for measuring neurotransmitters in the brain. Developed by J.H. Gaddum in 1960, this technique replaced the cortical cup technique for observing neurotransmitters. In order to analyze concentrations of analytes such as neurotransmitters, a probe consisting of two concentric tubes is implanted in the region of interest. A pump then pushes a neutral fluid such as saline or Ringer's solution through one of the tubes, while another pump extracts the fluid through the other tube. While outside the tubes, the perfusion fluid picks up physiological substances such as neurotransmitters that are present in the area. The concentration of analytes of interest can then be measured in the expelled fluid, indicating in which concentration they are present at the site of interest at any given time. The advent of concentric microdialysis probes in the 1980s resulted in push-pull sampling falling out of favor, as such probes require less monitoring, and are less invasive than the higher flow rate push-pull probes (>10 microliter/min), which could result in lesions if flow is unbalanced. With the advent of microfluidics and miniaturized probes, low-flow push–pull sampling was developed in 2002.…
Key claims
No claims recorded.
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?
Bibliography
No sources recorded.
Key claims and bibliography are generated from the same tracked claims and sources as the article page.