The RA3 multiple unit ( , named "Orlan", ) is a class of Russian diesel multiple units (type 2 railbus) built by Metrovagonmash between 2019 and 2022 in Mytishchi, Russia. Along with RA1 and RA2, the multiple unit is classified as a railbus by its manufacturer. The factory type of the multiple unit is model 753. It was developed by TMH Engineering LLC. The 2 car and 3 car variants were built. As of 2025, the multiple units are operated by Russian Railways, Central Suburban Passenger Company, Northern Suburban Passenger Company, Sakhalin Passenger Company, Bashkortostan Suburban Railway Company, Severo-Western Passenger Company, and other companies.
The RA3 multiple unit ( , named "Orlan", ) is a class of Russian diesel multiple units (type 2 railbus) built by Metrovagonmash between 2019 and 2022 in Mytishchi, Russia. Along with RA1 and RA2, the multiple unit is classified as a railbus by its manufacturer. The factory type of the multiple unit is model 753. It was developed by TMH Engineering LLC. The 2 car and 3 car variants were built.
As of 2025, the multiple units are operated by Russian Railways, Central Suburban Passenger Company, Northern Suburban Passenger Company, Sakhalin Passenger Company, Bashkortostan Suburban Railway Company, Severo-Western Passenger Company, and other companies. The MTU 6H 1800 R83 diesel engine is a four-stroke, inline, six-cylinder engine with a direct fuel injection system and turbocharging. The engine's cylinders are arranged horizontally in a row at the same level as the crankshaft.
The engine cylinder head is equipped with six high-pressure fuel injection pumps, one for each cylinder. The diameter of each cylinder is 128 mm, the piston stroke is 166 mm, and the total cylinder displacement is 6 × 2.14 = 12.84 liters. The engine's rated power is 360 kW at a rotational speed of 1800 rpm, the maximum torque is 2200 N⋅m at 1300 rpm, and the specific fuel consumption is 210–218 g/kWh at rated power and 198–200 g/kWh in optimal mode (at 60% of rated power).
The engine's length, width, and height are 1465 × 1331 × 715 mm, and its dry weight is 990 kg. The engine is designed to run on diesel fuel that meets the EN 590 standard. The fuel is stored in two fuel tanks, each with a capacity of 350 liters, mounted on the frame under the car body and connected by a pipeline.
A centrifugal fuel lift pump is installed between them, which pumps fuel into the supply line before starting the diesel through fuel filters and heat exchangers to heat it in cold temperatures, as well as during the operation of fuel heaters through their circuit. After the diesel starts, the fuel lift pump is turned off, and the engine's own fuel pump takes over, sending the fuel through individual high-pressure fuel pumps to the engine cylinder injectors.
Atmospheric air for fuel combustion is sucked in through the air duct and passes through the intake filter, after which it is compressed by the turbocharger and goes through the air cooler into the engine cylinders. Exhaust gases pass through the turbocharger turbine wheel to drive it and then through the noise muffler, where products of incomplete combustion are also separated from them, and then they exit into the atmosphere through the exhaust pipe that leads out through the roof.
The power unit has a liquid cooling system that includes an expansion tank, a pump driven by the engine via a belt, an electric pump for pre-heating mode when the diesel is off, and a piping system with heat exchangers. The coolant removes excess heat from the running engine, the hydraulic drive, the onboard generator, and the oil systems, and then, when the temperature is above 75°C, it is cooled in a fan-ventilated radiator.
Evidence and sources
During cold weather, before cooling in the radiator, it is also used to transfer heat to the cabin heating system and to warm up the fuel system. The normal operating temperature of the coolant is between 95 and 97°C, and the critical temperature at which the engine shuts down to prevent damage is 110°C. To allow the engine to start in low temperatures, there's an independent coolant heater that works off the battery or an external power source. The engine has two oil systems — one for lubrication and another for the hydrostatic auxiliary drive.
The engine lubrication oil is stored in the oil pan and is delivered to the moving parts through a filter and heat exchangers using an oil pump driven by the engine's crankshaft. In the hydrostatic auxiliary drive system, the oil is stored in a special tank and delivered through two independent circuits to drive the onboard generator and the fans for the charge air and coolant cooling system. In each circuit, a high-pressure hydraulic pump driven by the crankshaft moves the oil, which in turn drives the generator and fan hydraulic motors.
The fan speed is controlled by a metering valve with an electronic control system, depending on the temperature of the charge air and coolant. There is also information about the RA3 being assigned to TCH-32 depot of the South Urals Railway (Chelyabinsk) and TCH-7 of the Kuibyshev Railway (Ruzaevka).
Text derived from https://en.wikipedia.org/w/index.php?oldid=1376201907 under CC BY-SA 4.0; modifications have been made.