Radioactive tracer
≈ 10 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
carbon-14 as a radioactive tracer in a plant. A radioactive tracer, radiotracer, or radioactive label is a synthetic derivative of a natural compound in which one or more atoms have been replaced by a radionuclide (a radioactive atom).
By virtue of its radioactive decay, it can be used to explore the mechanism of chemical reactions by tracing the path that the radioisotope follows from reactants to products. Radiolabeling or radiotracing is thus the radioactive form of isotopic labeling. In biological contexts, experiments that use radioisotope tracers are sometimes called radioisotope feeding experiments.
Radioisotopes of hydrogen, carbon, phosphorus, sulfur, and iodine have been used extensively to trace the path of biochemical reactions. A radioactive tracer can also be used to track the distribution of a substance within a natural system such as a cell or tissue, or as a flow tracer to track fluid flow.
Radioactive tracers are also used to determine the location of fractures created by hydraulic fracturing in natural gas production. Radioactive tracers form the basis of a variety of imaging systems, such as, PET scans, SPECT scans and technetium scans. Radiocarbon dating uses the naturally occurring carbon-14 isotope as an isotopic label.
In radiopharmaceutical sciences some misuse of established scientific terms exist.…
carbon-14 as a radioactive tracer in a plant. A radioactive tracer, radiotracer, or radioactive label is a synthetic derivative of a natural compound in which one or more atoms have been replaced by a radionuclide (a radioactive atom).
By virtue of its radioactive decay, it can be used to explore the mechanism of chemical reactions by tracing the path that the radioisotope follows from reactants to products. Radiolabeling or radiotracing is thus the radioactive form of isotopic labeling. In biological contexts, experiments that use radioisotope tracers are sometimes called radioisotope feeding experiments.
Radioisotopes of hydrogen, carbon, phosphorus, sulfur, and iodine have been used extensively to trace the path of biochemical reactions. A radioactive tracer can also be used to track the distribution of a substance within a natural system such as a cell or tissue, or as a flow tracer to track fluid flow.
Radioactive tracers are also used to determine the location of fractures created by hydraulic fracturing in natural gas production. Radioactive tracers form the basis of a variety of imaging systems, such as, PET scans, SPECT scans and technetium scans. Radiocarbon dating uses the naturally occurring carbon-14 isotope as an isotopic label.
In radiopharmaceutical sciences some misuse of established scientific terms exist. Therefore an international "Working Group on Nomenclature in Radiopharmaceutical Chemistry and Related Areas" was formed in 20151 by the Society of Radiopharmaceutical Sciences (SRS).
Their goal was to clarify terminology and to establish a standardized nomenclature through global consensus, ensuring consistency and accuracy within the discipline.
Methodology
Isotopes of a chemical element differ only in the mass number. For example, the isotopes of hydrogen can be written as 1 H, 2 H and 3 H, with the mass number superscripted to the left. When the atomic nucleus of an isotope is unstable, compounds containing this isotope are radioactive.
Tritium is an example of a radioactive isotope. The principle behind the use of radioactive tracers is that an atom in a chemical compound is replaced by another atom, of the same chemical element. The substituting atom, however, is a radioactive isotope.
This process is often called radioactive labeling. The power of the technique is due to the fact that radioactive decay is much more energetic than chemical reactions. Therefore, the radioactive isotope can be present in low concentration and its presence detected by sensitive radiation detectors such as Geiger counters and scintillation counters.
George de Hevesy won the 1943 Nobel Prize for Chemistry "for his work on the use of isotopes as tracers in the study of chemical processes". There are two main ways in which radioactive tracers are used When a labeled chemical compound undergoes chemical reactions one or more of the products will contain the radioactive label.
Analysis of what happens to the radioactive isotope provides detailed information on the mechanism of the chemical reaction. A radioactive compound is introduced into a living organism and the radio-isotope provides a means to construct an image showing the way in which that compound and its reaction products are distributed around the organism.
Hydrogen
Tritium (hydrogen-3) is produced by neutron irradiation of 6 Li: 6 Li + n → 4 He + 3 H Tritium has a half-life days (approximately 12.32 years) and it decays by beta decay. The electrons produced have an average energy of 5.7 keV. Because the emitted electrons have relatively low energy, the detection efficiency by scintillation counting is rather low.
However, hydrogen atoms are present in all organic compounds, so tritium is frequently used as a tracer in biochemical studies.
Carbon
11 C decays by positron emission with a half-life of ca. 20 min. 11 C is one of the isotopes often used in positron emission tomography. 14 C decays by beta decay, with a half-life of 5730 years.
It is continuously produced in the upper atmosphere of the earth, so it occurs at a trace level in the environment. However, it is not practical to use naturally occurring 14 C for tracer studies. Instead it is made by neutron irradiation of the isotope 13 C which occurs naturally in carbon at about the 1.1% level.
14 C has been used extensively to trace the progress of organic molecules through metabolic pathways.
Phosphorus
32 P is made by neutron bombardment of 32 S 32 S + n → 32 P + p It decays by beta decay with a half-life of 14.29 days. It is commonly used to study protein phosphorylation by kinases in biochemistry. 33 P is made in relatively low yield by neutron bombardment of 31 P. It is also a beta-emitter, with a half-life of 25.4 days.
Though more expensive than 32 P, the emitted electrons are less energetic, permitting better resolution in, for example, DNA sequencing. Both isotopes are useful for labeling nucleotides and other species that contain a phosphate group.
Sulfur
35 S is made by neutron bombardment of 35 Cl 35 Cl + n → 35 S + p It decays by beta-decay with a half-life of 87.51 days. It is used to label the sulfur-containing amino-acids methionine and cysteine. When a sulfur atom replaces an oxygen atom in a phosphate group on a nucleotide a thiophosphate is produced, so 35 S can also be used to trace a phosphate group.
Technetium
99m Tc is a very versatile radioisotope, and is the most commonly used radioisotope tracer in medicine. It is easy to produce in a technetium-99m generator, by decay of 99 Mo. 99 Mo → 99m Tc + + The molybdenum isotope has a half-life of approximately 66 hours (2.75 days), so the generator has a useful life of about two weeks.
Most commercial 99m Tc generators use column chromatography, in which 99 Mo in the form of molybdate, MoO 4 2− is adsorbed onto acid alumina (Al 2 O 3 ). When the 99 Mo decays it forms pertechnetate TcO 4 − , which because of its single charge is less tightly bound to the alumina.
Pulling normal saline solution through the column of immobilized 99 Mo elutes the soluble 99m Tc, resulting in a saline solution containing the 99m Tc as the dissolved sodium salt of the pertechnetate. The pertechnetate is treated with a reducing agent such as Sn 2+ and a ligand.
Different ligands form coordination complexes which give the technetium enhanced affinity for particular sites in the human body. 99m Tc decays by gamma emission, with a half-life: 6.01 hours. The short half-life ensures that the body-concentration of the radioisotope falls effectively to zero in a few days.
Iodine
123 I is produced by proton irradiation of 124 Xe. The caesium isotope produced is unstable and decays to 123 I. The isotope is usually supplied as the iodide and hypoiodate in dilute sodium hydroxide solution, at high isotopic purity. 123 I has also been produced at Oak Ridge National Laboratories by proton bombardment of 123 Te.
123 I decays by electron capture with a half-life of 13.22 hours. The emitted 159 keV gamma ray is used in single-photon emission computed tomography (SPECT). A 127 keV gamma ray is also emitted.
125 I is frequently used in radioimmunoassays because of its relatively long half-life (59 days) and ability to be detected with high sensitivity by gamma counters. 129 I is present in the environment as a result of the testing of nuclear weapons in the atmosphere. It was also produced in the Chernobyl and Fukushima disasters.
129 I decays with a half-life of 15.7 million years, with low-energy beta and gamma emissions. It is not used as a tracer, though its presence in living organisms, including human beings, can be characterized by measurement of the gamma rays.
Applications
In metabolism research, tritium and 14 C-labeled glucose are commonly used in glucose clamps to measure rates of glucose uptake, fatty acid synthesis, and other metabolic processes. While radioactive tracers are sometimes still used in human studies, stable isotope tracers such as 13 C are more commonly used in current human clamp studies.
Radioactive tracers are also used to study lipoprotein metabolism in humans and experimental animals. In medicine, tracers are applied in a number of tests, such as 99m Tc in autoradiography and nuclear medicine, including single-photon emission computed tomography (SPECT), positron emission tomography (PET) and scintigraphy.
The urea breath test for helicobacter pylori commonly used a dose of 14 C labeled urea to detect h. pylori infection. If the labeled urea was metabolized by h. pylori in the stomach, the patient's breath would contain labeled carbon dioxide.
In recent years, the use of substances enriched in the non-radioactive isotope 13 C has become the preferred method, avoiding patient exposure to radioactivity. In hydraulic fracturing, radioactive tracer isotopes are injected with hydraulic fracturing fluid to determine the injection profile and location of created fractures.
Tracers with different half-lives are used for each stage of hydraulic fracturing. In the United States amounts per injection of radionuclide are listed in the US Nuclear Regulatory Commission (NRC) guidelines. According to the NRC, some of the most commonly used tracers include antimony-124, bromine-82, iodine-125, iodine-131, iridium-192, and scandium-46.
A 2003 publication by the International Atomic Energy Agency confirms the frequent use of most of the tracers above, and says that manganese-56, sodium-24, technetium-99m, silver-110m, argon-41, and xenon-133 are also used extensively because they are easily identified and measured.